Specifications
PowerConnect B-8000 Hardware Reference Manual 33
53-1001788-01
Environmental requirements
A
Environmental requirements
Table 9 lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
General specifications
Table 10 lists the general specifications for the PowerConnect B-8000.
Input system power (including power supply and fan
FRUs)
Idle: 206 W
Maximum: 306 W
Input voltage 85-264 VAC
Input line frequency 47-63 Hz
BTU rating 1044.11 BTU/hr
Inrush current Maximum of 60A for period of 10-150mS
Input line protection Both AC lines are fused
TABLE 8 Power Supply Specifications
Specification Value
TABLE 9 Environmental requirements
Condition Acceptable during operation Acceptable During Non-Operation
Ambient
Temperature
0º to 40º C
32º to 104º F
-25º to 70º C
-13º to 158º F
Humidity 10% to 85% RH non-condensing, at
40º C (104º F)
10% to 90% RH non-condensing, at 70º C
(158º F)
Altitude 0 to 3 km (9,842 feet) above sea level 0 to 12 km (39,370 feet) above sea level
Shock 20 G, 6 ms, half-sine wave 33 G, 11 ms, half-sine wave, 3/eg Axis
Vibration 0.5 G sine, 0.4 gms random, 5-500 Hz 2.0 G sine, 1.1 gms random, 5-500 Hz
Air flow Maximum - 71.36 cmh (42 cfm)
Nominal - 59.47 cmh (35 cfm)
NA
Heat dissipation 1044 BTU/hr (32 port configuration) NA
TABLE 10 General specifications
Specification Description
Configurable port types F_Port, FL_Port, E_Port, and M_Port
System architecture Nonblocking shared-memory switch
System processor Freescale MPC8548 x 1.3GHz
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6
FC-IP (IP-over-Fibre Channel) Complies with FC-IP 2.3 of FCA profile