Installation guide
Table Of Contents
- Contents
- About This Document
- Product Overview
- Installing the PowerConnect B-FCX Switch
- Unpacking the device
- Installation tasks
- Installation precautions
- Preparing the installation site
- Powering on the system
- Attaching a PC or terminal
- Installing and replacing a power supply unit
- Installing or replacing fan trays on PowerConnect B-FCX624s and PowerConnect B-FCX648s devices
- Installing or replacing fan trays on PowerConnect B-FCX624 and PowerConnect B-FCX648 devices
- Installing an optional module on PowerConnect B-FCX624s or PowerConnect B-FCX648s devices
- Installing an optional module in PowerConnect B-FCX624 and PowerConnect B-FCX648 devices
- Checking Network Devices and Testing Connectivity
- Managing the PowerConnect B-FCX Hardware
- Hardware Specifications
- Troubleshooting
- Regulatory Statements
- Cautions and Danger Notices

PowerConnect B-FCX Switch Hardware Installation Guide 47
53-1002267-01
Troubleshooting network connections
3
The output from this command appears below.
Syntax: show cable-diag tdr <port-num>
Table 20 defines the fields shown in this output.
Digital optical monitoring
You can configure your device to monitor optical transceivers in the system, either globally or by
specified port. When this feature is enabled, the system monitors the temperature and signal
power levels for the optical transceivers in the specified ports. Console messages and syslog
messages are sent when optical operating conditions fall below or rise above the XFP, SFP, and
SFP+ manufacturer’s recommended thresholds. For more information about digital optical
monitoring, refer to PowerConnect B-FCX Series Configuration Guide.
TABLE 20 Cable statistics
This Line... Displays...
Port The port that was tested.
Speed The current line speed of the port.
Local pair The local link name.
Pair Length The cable length when terminated, or the distance to the point of fault when the line
is not up.
Remote pair The remote link name.
Pair status The status of the link. This field displays one of the following:
• Terminated: The link is up.
• Shorted: A short is detected in the cable.
• Open: An opening is detected in the cable.
• ImpedMis: The impedance is mismatched.
• Failed: The TDR test failed.
PowerConnect# show cable-diag tdr 1/1/1
Port Speed Local pair Pair Length Remote pair Pair status
--------- ----- ---------- ----------- ----------- -----------
1/1/1 1000M Pair A <50M Pair B Terminated
Pair B <50M Pair A Terminated
Pair C <50M Pair D Terminated