Installation Manual
BigIron RX Installation Guide 61
53-1001811-01
Installing a BigIron RX-32 switch
2
Follow the steps given below to install a BigIron RX-32 chassis.
1. Ensure the rack is in its permanent location and is secured to the building. Ensure that the
installation site allows adequate clearance for both airflow, installation, and maintenance.
2. Move the pallet and chassis as close to the installation site as possible.
3. Use a power drill with a large Phillips screwdriver attachment to remove the four L-brackets that
attach the base of the chassis to the inner pallet. Refer to Figure 41.
FIGURE 41 Location of L-Brackets holding the BigIron RX-32 chassis
4. Using a mechanical lift equipped with a lift plate, position the lift plate as close to the front of
the chassis as possible. Adjust the lift plate height to be even with the bottom of the chassis.
5. Slide the chassis onto the lift plate.
DANGER
Four or more people are required to position the unpopulated chassis into the rack.
DANGER
Do not use the handles on the power supply units or fan modules to position the chassis.
6. Secure the chassis to the mechanical lift with a strap to prevent tipping.
7. Carefully move the chassis and position it in front of the rack where it is to be installed.
8. Remove the strap securing the chassis to the lift.
9. With two people in front and two people in back, slide the chassis into the rack.
1 Remove brackets that hold chassis to base (two brackets on either side of chassis)
1