Reference Guide
IronWare Software Release 02.8.00a for Brocade BigIron RX Series Swtches
Release Notes v 1.0 Page 31 of 40
Closed defects with code change in Multi-Service IronWare Release
02.8.00a
Defect ID: DEFECT000350761 Technical Severity: Critical
Summary: Under certain VRRP configurations Application Buffers may become depleted.
Symptom: Under certain VRRP configurations Application Buffers may become depleted causing unexpected reset of the
LP.
Feature: VRRP
Function: VRRPE
Probability: Medium
Found in Release: RX 02.7.03 Service Request ID: 601157
Defect ID: DEFECT000325041
Technical Severity: Medium
Summary: SNMP PIM interface table query returns inaccurate data.
Symptom: CLI command “show ip pim int” does not display all interfaces and displays an incorrect mask.
Feature: SNMP Management Function: Multicast Mib
Probability: High
Found in Release: RX 02.7.03
Service Request ID: 264854
Defect ID: DEFECT000355837 Technical Severity: Medium
Summary: Message buffer depletion on management module is possible when duplicate IP address is detected.
Symptom: In rare conditions, due to buffer depletion all the LPs may reset due to the loss of heartbeat
Feature: SYSTEM
Function: SNM
Probability: Medium
Found in Release: RX 02.7.03 Service Request ID: 631847
Defect ID: DEFECT000362014
Technical Severity: Medium
Summary: The CLI command "show memory" may show a negative value for os_malloc count and os_free count, after
some time.
Symptom: Display problem only in the "show memory" values for os_malloc count and os_free count showing negative
values.
Feature: SYSTEM
Function: Flash memory
Probability: Low
Found in Release: RX 02.7.02 Service Request ID: 646359