Defect ID Technical Severity Summary of Software Fixes in R02.7.02a
104389 High
Summary: TCP initial sequence number generation does not fully
conform to RFC 793.
Probability: Medium
Feature: TCP Stack
Function: IP
Reported in Release: BigIron RX R02.7.02
104610 Medium
Summary: Higher than normal CPU utilization on the management
interface when attempting to ping a non-existent host in the OSPF
network.
Probability: High
Feature: ARP
Function: IP Stack
Reported in Release: BigIron RX R02.7.02
104691 Medium
Summary: Duplicate syslog messages and traps are generated
when configuring “snmp-server contact” or “snmp-server
location
Probability: Medium
Feature: SNMP Management
Function: Syslog
Reported in Release: BigIron RX R02.7.02
104759 Medium
Summary: No log entry or trap is generated when a standby
management module transitions from “standby (ready state)” to
“standby (down)”
Probability: Medium
Feature: System
Function: Syslog
Reported in Release: BigIron RX R02.6.00c
104986 Low
Summary: The show ipv6 route command give “C” as the type
code for directly connected routes in one part of the output and “D”
as the type code in another.
Probability: Medium
Feature: IPv6 Routing
Function: CLI