4. Verify that the code has been successfully copied by entering the following command at any level
of the CLI:
show flash
5. The output will display the compressed boot ROM code size and the boot code version.
6. Upgrade the flash code as instructed in the following section.
Upgrading the Flash Code
1. Place the new flash code on a TFTP server to which the Brocade device has access.
2. Enter the following command at the Privileged EXEC level of the CLI (example:
FastIron#) to
copy the flash code from the TFTP server into the flash memory:
copy tftp flash <ip-addr> <image-file-name> primary | secondary
3. Verify that the flash code has been successfully copied by entering the following command at any
level of the CLI:
show flash
4. If the flash code version is correct, go to Step 5. Otherwise, go to Step 1.
5. Reload the software by entering the following command:
reload
(The reload command boots from the default boot source, which is the primary flash area by
default)
Technical Support
Contact your switch supplier for hardware, firmware, and software support, including product repairs and
part ordering. To expedite your call, have the following information immediately available:
1. General Information
• Technical Support contract number, if applicable
• Switch model
• Switch operating system version
• Error numbers and messages received
• Detailed description of the problem, including the switch or network behavior immediately
following the problem, and specific questions
• Description of any troubleshooting steps already performed and the results
2. Switch Serial Number