Owner's Manual

Managing a Switch Stack 171
At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PCM6348 PCM6348 OK 9.19.0.2
2 Unassigned PCM6348 Not Present 0.0.0.0
3 Mgmt Switch PCM6348 PCM6348 OK 9.19.0.2
4 Stack Member PCM6348 PCM6348 OK 9.19.0.2
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member PCM6348 PCM6348 OK 9.19.0.2
3 Mgmt Switch PCM6348 PCM6348 OK 9.19.0.2
4 Stack Member PCM6348 PCM6348 OK 9.19.0.2