CLI Reference Guide
clock timezone
clock timezone <name> <-23 to 23>
Description
This command sets the time zone on the controller.
Syntax
Parameter Description Range
<name>
Name of the time zone. 3-5 characters
-23 to 23
Hours offset from UTC. -23 to 23
Usage Guidelines
The name parameter can be any alphanumeric string, but cannot start with a colon (:). A time zone name longer
than five characters is not accepted. If you enter a time zone name containing punctuation, the command is
accepted, but the time zone is set to UTC.
Example
The following example configures the timezone to PST with an offset of UTC - 8 hours.
clock timezone PST -8
Command History
This command was introduced in ArubaOS 1.0
Command Information
Platforms Licensing Command Mode
All platforms Base operating system Config mode on master controllers
Dell PowerConnect W-Series ArubaOS 6.2 | Reference Guide clock timezone | 187