User guide

16 AirWave 7.5.6 | Release Notes
Known Issues
Table 8 below lists known issues in AirWave 7.5.6:
Table 9 below lists known issues in AirWave 7.5.5:
DE12187 Added Alcatel Lucent AP 68 (and 68p) to the VisualRF catalog_repository.xml. These devices are now
available for selection and now display heat maps.
US8451 For fresh installs beginning with AMP 7.5, the Use Global Aruba Configuration value on AMP Setup >
General now defaults to No. Note that for upgrades to AirWave 7.5, this value will still default to Yes.
Table 8 Known Issues in AirWave 7.5.6
ID Description
DE12883 In VisualRF, exporting a set of floor plans from one AMP and importing them into another can
sometimes result in missing floor plans.
DE12928 An issue exists with Rogue Containment. In some cases, AMP does not push the Contained Rogue
RAPIDS Classification override to the controller. This behavior can occur even if the Manage rogue AP
containment and Manage rogue AP containment in monitor-only mode options are set to Yes.
DE12932 A “Server communication error” message can sometimes be seen on pages that contain graphs. This
issue occurs in IE 9 browsers that have the Do not save encrypted pages to disk setting enabled.
Microsoft recommends turning off this setting. Refer to support.microsoft.com/kb/2549423 for
additional information.
Table 9 Known Issues in AirWave 7.5.5
ID Description
DE12632 An issue exists with regards to lingering interface data after devices are swapped. When a switch1 is
unplugged, and switch2 is given switch1’s IP address, the interface data from swtich1 still exists.
DE12744 In some cases, the Daily Wireless Network Usage report might not include any data in the Usage
graph. This is currently being investigated.
DE12752 When a Management Captive Portal certificate exists on a master controller, a mismatch that cannot be
overridden can occur when uploading a different certificate on a local controller.
DE12767 When a radio noise trigger is set for noise levels greater than a certain dBm value, alerts are being sent
for values less than the set value. For example, if a trigger is set for values equal to or greater than
-70dBm, alerts are still being sent when the noise level falls between -90 and -80dBm.
DE12783 A Device Down alert may be reported even though the reported device was never down. The
circumstances under which this behavior occurs is currently being investigated.
DE12789 In some cases, AMP may report that clients are connected to a radio that is actually disabled on the
controller.
DE12797 In VisualRF, DWG files that include cross-reference bindings are not supported. Attempting to import
these into AMP can result in poor-quality images.
DE12800 An issue exists when creating a global group and allowing subscriber overrides for the Device Type
setting. When overrides are allowed on the master controller Group Display options, a configured
“copy” of the global group does not properly remove devices that are removed from the master
controller group. If you notice this issue, then please perform the following steps:
1. Discontinue managing group configuration for the MAMP from the MC. (It is not necessary to delete
the MAMP from the MC; not managing group configuration is sufficient.)
2. On the MAMP, determine if there are any subscriber groups for the affected global group. If there
are none, delete the global group on the MAMP and skip to step four. Otherwise, continue with step
3.
3. Edit the device preferences on the global group of the MAMP so that the preferences match the MC.
4. Enable managing of group configuration for the MAMP on the MC.
Table 7 Resolved Issues in AirWave 7.5.0 (Continued)
ID Description