28. Insert the backup copy of the IntranetWare 4.11 NIC driver diskette into the diskette drive and press <Enter> to
continue.
A list of LAN drivers on the diskette appears.
29. Note and select the name of the driver you need to install and press <Enter>.
The driver is copied to the hard-disk drive.
30. At the
Save existing file Y/N prompt, type y or n as necessary and press <Enter>.
A LAN driver configuration screen appears.
31. Press <Alt><Esc> to switch to the console prompt, type load driver_filename, and press <Enter>.
A list of slot numbers separated by commas is displayed.
32. Write down all slot numbers that are listed and press <Esc> to clear the command line. Press <Alt><Esc> to
return to the installation screen.
33. Type the appropriate values for the configuration parameters, including the slot number for the network adapter,
pressing <Enter> after each entry.
34. Select Save parameters and continue, and then press <Enter>.
35. Repeat steps 25 through 34 for each network adapter in your system.
36. Select Continue Installation and press <Enter> to create disk partitions, system volumes, and NetWare Directory
Services according to the instructions provided in the IntranetWare User's Guide.
37. If prompted to edit the startup.ncf file, find the entry load sgscsi.cdm and replace it with load scsihd.cdm. Verify
that the load command line and slot number for your host adapter are listed correctly in the startup.ncf file.
For further information about editing the startup.ncf file, see Using startup.ncf and autoexec.ncf.
Your SCSI drivers have been installed. Continue to the next section.
Installing the Dell-Supplied Novell Patches and Support Pack 5
If you purchased IntranetWare from Dell, the required Novell patches (including the latest revision of the IntranetWare
Support Pack recommended by Dell) are provided on the Dell IntranetWare Support CD.
To install the patches supplied on the Dell IntranetWare Support CD, follow these steps:
1. Start IntranetWare.
2. Insert the Dell IntranetWare Support CD into the server's CD-ROM drive.
3. At the console prompt, type
load cdrom and press <Enter>.
4. Type cd mount nwscd and press <Enter>.
5. Type nwscd:\dpatch and press <Enter>.
A menu lists several patches (including the IntranetWare Support Pack 5), a backup option for the files being
replaced by the IntranetWare Support Pack 5, and a reboot option.
Dell recommends that you accept the defaults as displayed.
6. Read the list of options and press <F10> to accept them.
The program copies files to your hard-disk drive.
7. At the message IntranetWare Support Package installation is complete! , press <Enter>.
8. At the console prompt, type down and press <Enter> to return to "downed server" mode.
9. At the console prompt, type exit to return to the MS-DOS prompt.
10. Remove the Dell IntranetWare Support CD.
11. Reboot the server.
IntranetWare 4.11 From Sources Other Than Dell
If you purchased IntranetWare 4.11 from a source other than Dell, you must apply the IntranetWare Support Pack
version 4 or later before IntranetWare SMP can be installed.
The current IntranetWare Support Pack is version 5 and is an MS-DOS-executable patch file (iwsp5b.exe) available for