Service Manual

Physical
Rack mount (1U):
Height 4.3 cm (1.7 inches)
Width 42.5 cm (16.7 inches)
Depth 55.8 cm (22 inches)
Weight 10 kg (23 lb) maximum configuration
Environmental
Temperature:
Operating 10°C to 35°C (50°F to 95°F) derated 0.5°C per 1000 ft
Non-operating –40°C to 65°C (–40°F to 149°F)
Maximum
gradient 10°C per hour maximum rate of change
Relative humidity:
Non-operating 5% to 95% (noncondensing) at 30°C
Maximum shock:
Operating six consecutively executed shock pulses in the positive and negative x, y, and z
axes (one pulse on each side of the system) of 41 G for up to 2 ms
Package six consecutively executed shock pulses in the positive and negative x, y, and z
axes (one pulse on each side of the system) of 71 G for 2 ms
Altitude:
Operating –16 to 3048 m (–50 to 10,000 ft)
High-potential ESD:
Electrostatic
discharge 15kV
Noise (maximum):
Acoustic noise < 45dbA @ 23°C ±2°C
Back to Contents Page