Codes and Messages 3-13
Alert Messages from the Dell
OpenManage HIP Application
The Dell OpenManage Hardware Instrumentation Package (HIP) server man-
agement application generates alert messages that appear in the simple
network management protocol (SNMP) trap log file. To see the trap log, select
any enterprise under the SNMP trap log icon.
Alert log messages consist of information, status, warning, and failure mes-
sages for drive, temperature, fan, and power conditions. They can assist you
with identifying a problem and may provide you with information to help you
resolve the problem.
Table 3-3 lists some of the alert log messages from the Dell OpenManage HIP
application.
Table 3-3. Dell OpenManage HIP Application Alert Log
Messages
Message Cause Corrective Action
Automatic
management
notification
has occurred
The server stopped
functioning and
called the notification
number specified in
the DC Console
Actions tab.
The server will
reboot if the Reset
or Power Cycle
option was selected
in the Action on
Hung Server Notifi-
cation section of the
System Console
System tab. If nei-
ther option was
selected, the sys-
tem can be reset
using the Remote
Management fea-
ture in the Dell
Remote Assistant
Card utility.
Chassis
intrusion
detected
The chassis of an
attached system has
been opened.
Check to make sure
the system chassis
is closed.
Current
sensor
detected a
failure
The system is con-
suming more power
than the power sup-
plies are rated to
output. The power
supply name is pro-
vided.
Verify that all of the
expansion cards in
the system are func-
tioning properly.
Verify that the load
requirements of the
hardware config-
ured in the system
does not exceed the
capacity of the
power supplies.