3-20 Dell PowerEdge 6300 Systems User’s Guide
26. Enter the appropriate values for the configuration parameters, includ-
ing the slot number for the network adapter, pressing <Enter> after
each entry.
27. Repeat steps 19 through 26 for each network adapter in your system.
28. Select Continue the Installation to create disk partitions and system
volumes, and to specify volume names follow the procedures listed in
the NetWare User’s Guide.
29. When prompted to edit the startup.ncf file, find the entry load
sgscsi.cdm and replace the entry with load scsihd.cdm.
30. Verify that the load command line and slot number for your host
adapter is listed correctly in the startup.ncf file.
Refer to the NetWare User’s Guide for information about editing the startup.ncf
file.
Installing the Dell-Supplied Novell Patches
If you purchased NetWare 4.11 from Dell, the required NetWare 4.11 patches (includ-
ing IntranetWare Support Pack 4.0A) from Novell are provided on the Dell IntranetWare
Support CD. If you purchased NetWare 4.11 from another source, the required
NetWare patches are available for download from Novell’s World Wide Web site at
www.novell.com. Refer to the next section “Applying IntranetWare Support
Pack 4.0A” for instructions on installing IntranetWare Support Pack 4.0A from the file
downloaded from Novell’s Web site.
To install the patches supplied on the Dell IntranetWare Support CD, perform the
following procedure:
1. With the system turned on and running NetWare 4.11, insert the Dell
IntranetWare Support CD into the server’s CD-ROM drive.
2. At the console prompt, type load cdrom and press <Enter>.
3. Type cd mount nwscd and press <Enter>.
4. Type nwscd:\dpatch and press <Enter>.
A menu appears listing several patches (including the IntranetWare version 4.0A
Support Pack), a backup option for the files being replaced by the IntranetWare
4.0A Support Pack, and a reboot option.
The checkboxes for the patches and the IntranetWare Support Pack backup are
selected; the reboot option is not. Dell recommends that you accept the defaults
as displayed.
5. Read the list of options and press <F10> to accept them.