Users Guide

Table Of Contents
22 SAS Information Update
4
Turn off your system, reseat the hard drive, and restart the system.
If the problem is not resolved, continue to the next step.
5
Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.
See the documentation supplied with the host adapter for information about the configuration utility.
6
Ensure that the hard drive has been configured correctly for the RAID.
7
Exit the configuration utility and allow the system to boot to the operating system.
8
Ensure that the required device drivers for your controller card are installed and are configured
correctly. See the operating system documentation for more information.
9
Check the cable connections inside the system:
a
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
b
Open the system. See "Opening the System" in the
Installation and Troubleshooting Guide
.
c
Verify that the cable connections between the SAS backplane(s) and the SAS controller card are
correct. See Figure 1-5.
d
Verify that the SAS cables are securely seated in their connectors.
e
Verify that the power connectors on the SAS backplane(s) are securely seated in their connectors.
f
Close the system. See "Closing the System" in the
Installation and Troubleshooting Guide
.
g
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists,
see "Getting Help" in the
Installation and Troubleshooting Guide
.