Users Guide

# root (hd0,0)
# kernel /boot/vmlinuz-version ro root=/dev/sdal
# initrd /boot/initrd-version.img
#boot=/dev/sda
default=0
timeout=10
#splashimage=(hd0,2)/grub/splash.xpm.gz
serial --unit=1 --speed=57600
terminal --timeout=10 serial
title Red Hat Linux Advanced Server (2.4.9-e.3smp) root (hd0,0)
kernel /boot/vmlinuz-2.4.9-e.3smp ro root=/dev/sda1 hda=ide-scsi console=ttyS0
console=ttyS1,115200n8r
initrd /boot/initrd-2.4.9-e.3smp.img
title Red Hat Linux Advanced Server-up (2.4.9-e.3) root (hd0,00)
kernel /boot/vmlinuz-2.4.9-e.3 ro root=/dev/sda1 s
initrd /boot/initrd-2.4.9-e.3.im
4. Um mehreren GRUB-Optionen das Starten von Sitzungen der virtuellen Konsole über die serielle RAC-Verbindung zu
ermöglichen, fügen Sie die folgende Zeile allen Optionen hinzu:
console=ttyS1,115200n8r console=tty1
Das Beispiel zeigt, dass console=ttyS1,57600 zur ersten Option hinzugefügt wurde.
ANMERKUNG: Wenn der Bootloader oder das Betriebssystem serielle Umleitung wie GRUB oder Linux bereitstellt, muss
die BIOS-Einstellung Umleitung nach dem Start deaktiviert sein. Dadurch soll potenzielle Racebedingung mehrerer
Komponenten, die auf die serielle Schnittstelle zugreifen, vermieden werden.
Anmeldung an der virtuellen Konsole nach dem Start aktivieren
Fügen Sie in der Datei /etc/inittab eine neue Zeile hinzu, um agetty auf der seriellen COM2-Schnittstelle zu konfigurieren:
co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
Das folgende Beispiel zeigt eine Beispieldatei mit der neuen Zeile.
#inittab This file describes how the INIT process should set up #the system in a certain
run-level. #Author:Miquel van Smoorenburg #Modified for RHS Linux by Marc Ewing and
Donnie Barnes #Default runlevel. The runlevels used by RHS are: #0 - halt (Do NOT set
initdefault to this) #1 - Single user mode #2 - Multiuser, without NFS (The same as 3,
if you do not have #networking) #3 - Full multiuser mode #4 - unused #5 - X11 #6 -
reboot (Do NOT set initdefault to this) id:3:initdefault: #System initialization.
si::sysinit:/etc/rc.d/rc.sysinit l0:0:wait:/etc/rc.d/rc 0 l1:1:wait:/etc/rc.d/rc 1
l2:2:wait:/etc/rc.d/rc 2 l3:3:wait:/etc/rc.d/rc 3 l4:4:wait:/etc/rc.d/rc 4
l5:5:wait:/etc/rc.d/rc 5 l6:6:wait:/etc/rc.d/rc 6 #Things to run in every runlevel.
ud::once:/sbin/update ud::once:/sbin/update #Trap CTRL-ALT-DELETE ca::ctrlaltdel:/sbin/
shutdown -t3 -r now #When our UPS tells us power has failed, assume we have a few
#minutes of power left. Schedule a shutdown for 2 minutes from now. #This does, of
course, assume you have power installed and your #UPS is connected and working
correctly. pf::powerfail:/sbin/shutdown -f -h +2 "Power Failure; System Shutting Down"
#If power was restored before the shutdown kicked in, cancel it. pr:12345:powerokwait:/
sbin/shutdown -c "Power Restored; Shutdown Cancelled"
#Run gettys in standard runlevels co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
1:2345:respawn:/sbin/mingetty tty1 2:2345:respawn:/sbin/mingetty tty2 3:2345:respawn:/
sbin/mingetty tty3 4:2345:respawn:/sbin/mingetty tty4 5:2345:respawn:/sbin/mingetty tty5
6:2345:respawn:/sbin/mingetty tty6 #Run xdm in runlevel 5 #xdm is now a separate service
x:5:respawn:/etc/X11/prefdm -nodaemon
Fügen Sie in der Datei /etc/securetty eine neue Zeile mit dem Namen der seriellen tty für COM2 hinzu:
ttyS1
Einrichten der iDRAC-Kommunikation
133