Users Guide

Table Of Contents
2. Test the system memory using the MP Memory test to ensure that there are no DIMM failures.
3. Test the system using the ePSA to test the general hardware to ensure system health.
4. Complete a flee power and minimum to POST, while testing the system at each stage.
5. Check if there are any available updates on firmware (BIOS and iDRAC firmware).
6. Clear the system event logs
7. If the issue persists, contact Dell Tech Support team.
.
Troubleshooting a storage controller
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
NOTE: When troubleshooting a controller, see the documentation for your operating system and the controller.
NOTE: Both PERC connector and mini-Mezzanine connector are not hot-pluggable.
1. Run the appropriate diagnostic test. See the Using system diagnostics section.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Verify that the installed expansion cards are compliant with the expansion card installation guidelines.
5. Ensure that each expansion card is firmly seated in its connector.
6. Install the system cover.
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
9. Remove the system cover.
10. Remove all expansion cards installed in the system.
11. Install the system cover.
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13. Run the appropriate diagnostic test. See the Using system diagnostics section.
If the tests fail, see the Getting help section.
14. For each expansion card you removed in step 10, perform the following steps:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b. Remove the system cover.
c. Reinstall one of the expansion cards.
d. Install the system cover.
e. Run the appropriate diagnostic test. See the Using system diagnostics section.
If the problem persists, see the Getting help section.
OMSA flagging PERC driver
Issue: OpenManage Server Administrator (OMSA) flagging the PERC driver.
Solution: Dell EMC recommends that you download and install the latest BIOS, drivers, and systems management firmware on
your system. For more information, see the Downloading the drivers and firmware topic.
Importing or clearing foreign configurations using the foreign
configuration view screen
Prerequisites
50
Troubleshooting hardware issues