Users Guide

Table Of Contents
2. Let the system sit for 30 seconds to allow any remaining flea power to drain.
3. Boot to the operating system, and clear logs.
4. Update the iDRAC firmware to the latest version.
NOTE: If the issue persists, Dell recommends that you replace PERC and the PERC battery.
For more information about troubleshooting the PERC battery, see Additional Information for troubleshooting memory or
battery errors on the PERC controller section.
Creating non-raid disks for storage purpose
About this task
By default, all the disks are in RAID capable unconfigured state. The user can convert the RAID capable disks to non-RAID disks
using either the BIOS configuration utility or the UEFI/HII RAID configuration utility.
To create a non-RAID disk, perform the following steps in the BIOS Configuration Utility (<Ctrl> <R>):
Steps
1. On the Virtual Disk Mgmnt screen, use the arrow keys to highlight the PERC 9 adapter or Disk Group #.
2. Press <F2>.
The list of available action is displayed.
3. Click Convert to Non-RAID.
The Convert RAID Capable Disks to Non-RAID window is displayed.
4. Press the down-arrow key to highlight an available physical disk.
5. Press the spacebar to select the disk.
An X is displayed beside the selected physical disk(s).
6. Select OK.
Firmware or Physical disks out-of-date
Issue:The Firmware or Drives out of date adn results in unknown disk errors.
Solution:
Update the Firmware/ PERC Controller.
Cannot boot to Windows due to foreign configuration
About this task
When a foreign configuration exists in the controller, and you cannot boot to Windows, do the following:
Steps
1. Import the foreign configuration to the RAID controller. See, Importing foreign configuration using PERC.
2. Rebuild the failed hard drives. See, Rebuild.
3. Upgrade the iDRAC firmware/PERC. See, Downloading drivers and firmware.
Offline or missing virtual drives with preserved cache error
message
Error Message:
There are offline or missing virtual drives with preserved cache. Please check the cables
and ensure that all drives are present. Press any key to enter the configuration utility.
Troubleshooting hardware issues
55