Reference Guide
The following sections provide information about the objects in the cfgIpmiPetIpv6 group.
cfgIpmiPetIPv6Index (Read Only)
Description
Unique identier for the index corresponding to the trap.
Legal Values
1–4
Default
<index Values>
cfgIpmiPetIPv6AlertDestIpAddr
Description
Congures the IPv6 alert destination IP address for the trap.
Legal Values
IPv6 address
Default
<blank>
cfgIpmiPetIPv6AlertEnable (Read or Write)
Description
Enables or disables the IPv6 alert destination for the trap.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
0
cfgIpmiPef
This group is used to congure the platform event lters available on the managed server.
The event lters can be used to control policy related to actions that are triggered when critical events occur on the managed server.
The following sections provide information about the objects in the cfgIpmiPef group.
cfgIpmiPefName (Read Only)
Description
Species the name of the platform event lter.
Legal Values
A string of up to 255 characters.
Default
The name of the index lter.
cfgIpmiPefIndex (Read or Write)
Description
Species the index of a specic platform event lter.
Legal Values
• For iDRAC on Rack and Tower Servers: 1–22
• For iDRAC Enterprise on Blade Servers: 1–9
Default
The index value of a platform event lter object.
138