Reference Guide

cfgIpmiPefAction (Read or Write)
Description
Species the action that is performed on the managed server when the alert is triggered.
NOTE: For iDRAC on Rack and Tower servers, this object is read-only for indexes 20, 21, and 22.
Legal Values
0 (None)
1 (Power Down)
2(Reset)
3(Power Cycle)
Default
0
cfgIpmiPefEnable (Read or Write)
Description
Enables or disables a specic platform event lter.
Legal Values
1(TRUE)
0(FALSE)
Default
1
cfgIpmiPet
This group is used to congure platform event traps on the managed server.
The following sections provide information about the objects in the cfgIpmiPet group.
cfgIpmiPetIndex (Read Only)
Description
Unique identier for the index corresponding to the trap.
Legal Values
1–4
Default
The index value of a specic platform event trap.
cfgIpmiPetAlertDestIpAddr (Read/Write)
Description
Species the destination IPv4 address for the trap receiver on the network. The trap receiver receives an
SNMP trap when an event is triggered on the managed server.
Legal Values
A string representing a valid IPv4 address. For example, 192.168.0.67.
Default
0.0.0.0
cfgIpmiPetAlertEnable (Read or Write)
Description
Enables or disables a specic trap.
Legal Values
1 (TRUE)
139