Reference Guide

where,
DD = Day of the week
MM= Month
Date=Date
YYYY = Year
HH = hour
MM=Minutes
SS = Seconds
Default
Timestamp of the cumulative power consumption.
cfgServerCumulativePowerClear (Write Only)
Description
Clears the cfgServerCumulativePowerConsumption and
cfgServerCumulativePowerConsumptionTimeStamp values.
Legal Values
1
Default
None
cfgServerPowerPCIeAllocation (Read or Write)
Description
Amount of power allocated to the PCIe cards.
This object is applicable for iDRAC Enterprise only for specic Blade Servers and not for iDRAC on Rack and
Tower Servers.
You must have the Administrator privileges to modify the value for this object.
Legal Values
0 W: For platforms that do not support PCIe cards.
100 W — 500 W: For platforms that support PCIe cards.
Default
0: For platforms that do not support PCIe cards.
500 W: For platforms that support PCIe cards.
cfgServerPowerSupply
This group contains information related to the power supplies.
The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on
Blade Servers.
NOTE: The getcong subcommand always shows eight cfgServerPowerSupply indexes, even if two power supplies are
installed in the system or the system supports a maximum of two PSUs. For the uninstalled and unsupported units, all the
objects in the
cfgServerPowerSupply group displays a value of 0.
The following sections provide information about the objects in the cfgServerPowerSupply group.
cfgServerPowerSupplyIndex
Description
Species index of the PSU.
148