Reference Guide
System.ThermalSettings
This group provides information about the thermal settings of the server.
To know more about the platforms supported for AirExhaustTemp and FanSpeedOset settings, see the iDRAC User's Guide
available at www.dell.com/esmmanuals.
System.ThermalSettings.AirExhaustTemp (Read or Write)
Description Displays the air exhaust temperature and sets the exhaust temperature to any appropriate value.
NOTE: This attribute is platform dependent.
Legal Values
• 0 — 40°C
• 1 —45°C
• 2 — 50°C
• 3 — 55°C
• 255 — None
Default value 255 — None
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalSettings.BaseAlgorithm (Read or Write)
Description
Species the thermal base algorithm.
NOTE: This object is not applicable for Rack and Tower server.
Legal Values
• 0 — Auto
• 1 — Max Exhaust Temperature
• 2 — Min Power
Default values None
License Required iDRAC Express
Dependency None
System.ThermalSettings.MinimumFanSpeed (Read or Write)
Description
Species the minimum fan speed required.
NOTE: This attribute is platform dependent.
Legal Values MFSMinimumLimit — MFSMaximumLimit
Default Value 0
Write Privilege Not Applicable
License Required iDRAC Express or iDRAC Enterprise
Dependency None
193