Reference Guide
Output
Coredump is deleted.
Example
racadm coredumpdelete
Coredump request completed successfully
diagnostics
Description Collects and exports remote diagnostics report from iDRAC.
The results of the latest successfully run remote diagnostics are available and retrievable remotely through an
NFS or a CIFS share.
Synopsis To run a remote diagnostic report:
racadm diagnostics run -m <mode> -r <reboot type> -s <start time> -e
<expiration time>
To export a remote diagnostic report:
racadm diagnostics export -f <file name> -l <NFS or CIFS share location> -u
<username> -p <password>
Input
• —m <mode> — Species the type of diagnostic mode. The types are:
– Collect and export remote diagnostics report from the iDRAC.
The results of the latest successfully executed remote Diagnostics will be available and retrievable
remotely through an NFS or a CIFS share.
– 0(Express) — The express mode executes a subset of diagnostic tests.
– 1(Extended) — The extended mode executes all available diagnostics tests.
– 2(Both) — Runs express and extended tests serially in sequence.
• -f <filename> — Species the name of the conguration le.
• -l — Species the location of the network share (NFS or CIFS).
• -u <username> — Species the user name of the remote share to import the le.
• -p <password> — Species the password of the remote share to import the le.
• -r <reboot type> — Species the reboot type. The type can be one of the following:
– pwrcycle — Power cycle
– Graceful — Graceful reboot without forced shutdown
– Forced — Graceful reboot with forced shutdown
• -s <start time> — Species the start time for the scheduled job in yyyymmddhhmmss format. The
default value TIME_NOW starts the job immediately.
• -e <expiration time> — Species the expiry time for the scheduled job in yyyymmddhhmmss
format. The default value TIME_NA does not apply the waiting time.
NOTE: For the diagnostic report run operation, the time dierence between the -s and -e options
must be more than ve minutes.
Output
Provides the Job ID for the diagnostic operation.
Examples
• To initiate a remote diagnostic operation:
racadm diagnostics run -m 1 -r forced -s 20121215101010 -e TIME_NA
• To export a remote diagnostics report to CIFS share:
racadm diagnostics export -f diagnostics -l //192.168.0/cifs -u
administrator -p xxx
26