Reference Guide

-m <module> — Must be one of the following values:
server-<n> : where n = 1–16
server-<nx> : where n = 1–8; x = a, b, c, d (lower case)
--more — Displays one screen at a time and prompts the user to continue (similar to the UNIX more
command.)
Example
Display entire log.
racadm getsel
Display number of records in log.
racadm getsel -i
getsensorinfo
Description Displays the status for system sensors.
NOTE: For Dell PowerEdge FX2 chassis with FM120x4 server, the power related information is
not displayed.
NOTE: General purpose graphical processing unit (GPGPU) status is displayed only on
PowerEdge C4130 servers.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input -c — Compact output format.
NOTE: Chassis Controller is supported only on Dell PowerEdge FX2 and GPU sensors are displayed only on PowerEdge
C4130 servers.
Example
racadm getsensorinfo
Sensor Type : POWER
<Sensor Name>
<Status> <Type>
PS1 Status Present AC
Sensor Type : TEMPERATURE
<Sensor Name>
<Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board Inlet
Temp
Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board
Exhaust Temp
Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Sensor Type : FAN
<Sensor Name>
<Status> <Reading> <lc> <uc> <PWM %>
System Board
Fan1 RPM
Ok 5880 RPM 600 RPM NA 21%
38