Reference Guide

RACADM Proxy
Description
On the PowerEdge FX2/FX2s systems, you can manage the compute sleds and CMC using
the iDRAC’s RACADM Proxy feature that redirects commands from iDRAC to CMC. You
can return the CMC response to local or remote RACADM.to access the CMC conguration and reporting
features without placing the CMC on the management network. The CMC conguration commands are
supported through local proxy when local conguration is enabled on iDRAC.
NOTE: Local racadm and local racadm proxy runs with root user privilege.
Synopsis
Local RACADM proxy usage
racadm <CMC racadm subcommand> --proxy
Remote RACADM proxy usage
racadm <CMC racadm subcommand> -u <username> -p <password> -r <idrac-ip
connected to cmc> --proxy
NOTE:
The attribute racadm getconfig -g cfgractuning -o
cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC.
The attribute racadm get system.ChassisControl.ChassisManagementMonitoring
attribute must be enabled in iDRAC.
--proxy must be entered at the end of the command.
The root privilege is the default privilege for Local RACADM proxy.
The user privilege in the Remote RACADM proxy for CMC maps to iDRAC privilege.
Required CMC Privilege for an operation Required iDrac Privilege for proxy operation
CMC Login User Login
Chassis Conguration Administrator Congure
User Conguration Administrator Congure User
Clear Logs Administrator Logs
Chassis Control Administrator System Control
Server Administrator System Control
Test Alert User System Operations
Debug Command Administrator Debug
Fabric x Administrator (where x is A, B, or C) System Control
When CMC is not placed on the network, the import, export, and le operation commands to CIFS,
NFS, or FTP will fail.
When the Remote or Local RACADM Proxy operation is in progress, if the iDRAC is reset, then the
Proxy operation fails and the output is not displayed in Remote or Local RACADM.
When racadm getsystem.ChassisControl.ChassisManagementMonitoring attribute is
set to
monitor, all the users including root users can only view the attribute.
To congure, set the attribute to monitor and manage in CMC.
Input
-uSpecies the user name of the remote share that stores the catalog le.
-pSpecies the password of the remote share that stores the catalog le.
59