Reference Guide

To generate and view information about the inventory of physical disk drives, run the following command:
racadm storage get pdisks
racadm storage get pdisks -o
racadm storage get pdisks -o -p <property names separated by comma>
racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated
by comma>
racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated
by comma> -o
racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated
by comma> -o -p <property names separated by comma>
To get the list of physical disks, run the following command:
racadm storage get pdisks
To get the properties of PCIeSSD physical disk, run the following command:
racadm storage get pdisks:<PCIeSSD FQDD>
To generate and view information about the inventory of fans, run the following command:
racadm storage get fans --refkey <enclosure FQDDs separated by comma>
racadm storage get fans --refkey <enclosure FQDDs separated by comma > -o
racadm storage get fans --refkey <enclosure FQDDs separated by comma> -o -
p <property names separated by comma>
To generate and view information about the inventory of EMMs, run the following command:
racadm storage get emms -refkey <enclosure FQDDs separated by comma>
racadm storage get emms --refkey <enclosure FQDDs separated by comma> -o
racadm storage get emms --refkey <enclosure FQDDs separated by comma> -o -
p <property names separated by comma>
To generate and view information about the inventory of PSU, run the following command:
racadm storage get psus -refkey <enclosure FQDDs separated by comma>
racadm storage get psus --refkey <enclosure FQDDs separated by comma> -o
racadm storage get psus --refkey <enclosure FQDDs separated by comma> -o -
p <property names separated by comma>
Conguration
To view the help details for a conguration command, run the following command:
racadm storage help <command>
where command can take below values
converttoraid, converttononraid, controllers, clearconfig,
createsecuritykey, createvd, deletesecuritykey, deletevd, encryptvd,
enclosures, emms, fans, hotspare, importconfig, ccheck, secureerase,
preparetoremove, blink, unblink, cancelcheck, init, modifysecuritykey,
psus, pdisks, resetconfig, tempprobes, vdisks, and patrolread.
To create, delete, and secure the virtual disks. To start or stop the consistency check on the specied
virtual disk, run the following command:
racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-
wp {wt|wb|wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|128k|
256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp
75