Reference Guide

{enabled|disabled|default}] [-name <VD name>] [-size <VD size>{b|k|m|g|
t}] [-T10PIEnable]
racadm storage init:<VD FQDD> -speed {fast|full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -xxx
<passphrase>
racadm storage modifysecuritykey:<Controller FQDD> -key <Key id>-xxx <old
passphrase> -xxx <new passphrase>
racadm storage deletesecuritykey:<Controller FQDD>
racadm storage ccheck:<vdisk fqdd>
racadm storage cancelcheck:<vdisk fqdd>
To convert the physical disk drives and assign or delete a hotspare. To scan physical disks connected to a
controller and detect problem, run the following command:
racadm storage converttononraid:<PD FQDD>
racadm storage converttoraid:<PD FQDD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes -type dhs -
vdkey: <FQDD of VD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes –type ghs
racadm storage hotspare:<Physical Disk FQDD> -assign no
racadm storage patrolread:<controller FQDD> -state start|stop
NOTE: If the –assign option is no, you cannot add other options. If the –assign option is yes
and if the -type option is not present, the global hotspare (ghs) is created by default.
To reset, clear, and import the storage conguration to the controller, run the following command:
racadm storage importconfig:<Controller FQDD>
racadm storage resetconfig:<Controller FQDD>
racadm storage clearconfig:<Controller FQDD>
To start or stop a blink or identify operation on the specied or PCIeSSD device, run the following
command:
racadm storage blink:<FQDD>
racadm storage blink:<PCIeSSD FQDD>
racadm storage unblink:<FQDD>
racadm storage unblink:<PCIeSSD FQDD>
NOTE: The Start or Stop a Blink feature is not supported for HHHL PCIe SSD devices.
To prepare the PCIeSSD drive for removal, run the following command:
racadm storage preparetoremove <PCIeSSD FQDD>
NOTE: The Prepare to Remove task is not supported for HHHL PCIe SSD devices.
To perform a secure erase operation on PCIeSSD device, run the following command:
racadm storage secureerase:<PCIeSSD FQDD>
NOTE: You can also run the command using raid in place of the storage command.
Input
-oSpecies the optimized version.
-pSpecies the property name.
--refkeySpecies the controller or enclosure FQDDs.
-rl — Sets the storage level.
76