CLI Guide
Table Of Contents
- Integrated Dell Remote Access Controller 9 RACADM CLI Guide
- Contents
- Introduction
- Running Get and Set
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- help and help subcommand
- arp
- autoupdatescheduler
- bioscert
- biosscan
- cd
- cd ..
- clearasrscreen
- clearpending
- closessn
- clrsel
- connect
- coredump
- coredumpdelete
- diagnostics
- driverpack
- eventfilters
- exposeisminstallertohost
- fcstatistics
- frontpanelerror
- fwupdate
- gethostnetworkinterfaces
- getled
- getniccfg
- getraclog
- getractime
- getremoteservicesstatus
- getsel
- getsensorinfo
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- groupmanager
- httpsbootcert
- hwinventory
- ifconfig
- infinibandstatistics
- inlettemphistory
- jobqueue
- krbkeytabupload
- lclog
- license
- netstat
- networktransceiverstatistics
- nicstatistics
- ping
- ping6
- racadm proxy
- racdump
- racreset
- racresetcfg
- recover
- remoteimage
- rollback
- sekm
- serialcapture
- sensorsettings
- serveraction
- setled
- setniccfg
- sshpkauth
- sslcertdelete
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslkeyupload
- sslresetcfg
- storage
- supportassist
- swinventory
- switchconnection
- systemerase
- systemperfstatistics
- techsupreport
- testalert
- testemail
- testrsyslogconnection
- testtrap
- traceroute
- traceroute6
- update
- usercertupload
- usercertview
- vflashpartition
- vflashsd
- vmdisconnect
- iDRAC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgStaticLanNetworking
- cfgNicStaticEnable (Read or Write)
- cfgNicStaticIPv4Enable (Read or Write)
- cfgNicStaticIpAddress (Read or Write)
- cfgNicStaticUseDhcp (Read or Write)
- cfgNicStaticNetmask (Read or Write)
- cfgNicStaticGateway (Read or Write)
- cfgDNSStaticServersFromDHCP (Read or Write)
- cfgDNSStaticServer1 (Read or Write)
- cfgDNSStaticServer2 (Read or Write)
- cfgDNSStaticDomainName(Read or Write)
- cfgDNSStaticDomainNameFromDHCP (Read or Write)
- cfgRemoteHosts
- cfgRhostsFwUpdateTftpEnable (Read or Write)
- cfgRhostsFwUpdateIpAddr (Read or Write)
- cfgRhostsFwUpdatePath (Read or Write)
- cfgRhostsSmtpServerIpAddr (Read or Write)
- cfgRhostsSyslogEnable (Read or Write)
- cfgRhostsSyslogPort (Read or Write)
- cfgRhostsSyslogServer1 (Read or Write)
- cfgRhostsSyslogServer2 (Read or Write)
- cfgRhostsSyslogServer3 (Read or Write)
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgSerialBaudRate (Read or Write)
- cfgSerialConsoleEnable (Read or Write)
- cfgSerialConsoleQuitKey (Read or Write)
- cfgSerialConsoleIdleTimeout (Read or Write)
- cfgSerialConsoleNoAuth (Read or Write)
- cfgSerialConsoleCommand (Read or Write)
- cfgSerialHistorySize (Read or Write)
- cfgSerialCom2RedirEnable (Read or Write)
- cfgSerialSshEnable (Read or Write)
- cfgOobSnmp
- cfgRacTuning
- cfgRacTuneConRedirPort (Read or Write)
- cfgRacTuneRemoteRacadmEnable (Read or Write)
- cfgRacTuneCtrlEConfigDisable
- cfgRacTuneHttpPort (Read or Write)
- cfgRacTuneHttpsPort (Read or Write)
- cfgRacTuneIpRangeEnable (Read or Write)
- cfgRacTuneIpRangeAddr (Read or Write)
- cfgRacTuneIpRangeMask (Read or Write)
- cfgRacTuneSshPort (Read or Write)
- cfgRacTuneConRedirEnable (Read or Write)
- cfgRacTuneConRedirEncryptEnable (Read or Write)
- cfgRacTuneAsrEnable (Read or Write)
- cfgRacTuneDaylightOffset (Read Only)
- cfgRacTuneTimezoneOffset (Read Only)
- cfgRacTuneLocalServerVideo (Read or Write)
- cfgRacTuneLocalConfigDisable (Read or Write)
- cfgRacTuneWebserverEnable (Read or Write)
- cfgRacTuneVirtualConsoleAuthorizeMultipleSessions (Read or Write)
- cfgRacTunePluginType (Read or Write)
- ifcRacManagedNodeOs
- cfgRacVirtual
- cfgServerInfo
- cfgActiveDirectory
- cfgADSSOEnable (Read or Write)
- cfgADDomainController1 (Read or Write)
- cfgADDomainController2 (Read or Write)
- cfgADDomainController3 (Read or Write)
- cfgADRacName (Read or Write)
- cfgADRacDomain (Read or Write)
- cfgADAuthTimeout (Read or Write)
- cfgADEnable (Read or Write)
- cfgADType (Read or Write)
- cfgADGlobalCatalog1 (Read or Write)
- cfgADGlobalCatalog2 (Read or Write)
- cfgADGlobalCatalog3 (Read or Write)
- cfgADCertValidationEnable (Read or Write)
- cfgADDcSRVLookupEnable (Read or Write)
- cfgADDcSRVLookupbyUserdomain (Read or Write)
- cfgADDcSRVLookupDomainName (Read or Write)
- cfgADGcSRVLookupEnable (Read or Write)
- cfgADGcRootDomain (Read or Write)
- cfgLDAP
- cfgLDAPBaseDN (Read or Write)
- cfgLDAPBindPassword (Write Only)
- cfgLDAPCertValidationEnable (Read or Write)
- cfgLDAPEnable (Read or Write)
- cfgLDAPGroupAttribute (Read or Write)
- cfgLDAPGroupAttributeIsDN (Read or Write)
- cfgLDAPPort (Read or Write)
- cfgLDAPSearchFilter (Read or Write)
- cfgLDAPServer (Read or Write)
- cfgLDAPUserAttribute (Read or Write)
- cfgLdapRoleGroup
- cfgStandardSchema
- cfgThermal
- cfgIpmiSol
- cfgIpmiLan
- cfgIpmiPetIpv6
- cfgIpmiPef
- cfgIpmiPet
- cfgUserDomain
- cfgServerPower
- cfgServerPowerStatus (Read Only)
- cfgServerPowerAllocation (Read Only)
- cfgServerActualPowerConsumption (Read Only)
- cfgServerPowerCapEnable (Read or Write)
- cfgServerMinPowerCapacity (Read Only)
- cfgServerMaxPowerCapacity (Read Only)
- cfgServerPeakPowerConsumption (Read Only)
- cfgServerPeakPowerConsumptionTimestamp (Read Only)
- cfgServerPowerConsumptionClear (Write Only)
- cfgServerPowerCapWatts (Read or Write)
- cfgServerPowerCapBtuhr (Read or Write)
- cfgServerPowerCapPercent (Read or Write)
- cfgServerPowerLastHourAvg (Read Only)
- cfgServerPowerLastDayAvg (Read Only)
- cfgServerPowerLastWeekAvg (Read Only)
- cfgServerPowerLastHourMinPower (Read Only)
- cfgServerPowerLastHourMinTime (Read Only)
- cfgServerPowerLastHourMaxPower (Read Only)
- cfgServerPowerLastHourMaxTime (Read Only)
- cfgServerPowerLastDayMinPower (Read Only)
- cfgServerPowerLastDayMinTime (Read Only)
- cfgServerPowerLastDayMaxPower (Read Only)
- cfgServerPowerLastDayMaxTime (Read Only)
- cfgServerPowerLastWeekMinPower (Read Only)
- cfgServerPowerLastWeekMinTime (Read Only)
- cfgServerPowerLastWeekMaxPower (Read Only)
- cfgServerPowerLastWeekMaxTime (Read Only)
- cfgServerPowerInstHeadroom (Read Only)
- cfgServerPowerPeakHeadroom (Read Only)
- cfgServerActualAmperageConsumption (Read Only)
- cfgServerPeakAmperage (Read Only)
- cfgServerPeakAmperageTimeStamp (Read Only)
- cfgServerCumulativePowerConsumption (Read Only)
- cfgServerCumulativePowerConsumptionTimeStamp (Read Only)
- cfgServerCumulativePowerClear (Write Only)
- cfgServerPowerPCIeAllocation (Read or Write)
- cfgServerPowerSupply
- cfgIPv6LanNetworking
- cfgIPv6Enable (Read or Write)
- cfgIPv6Address1 (Read or Write)
- cfgIPv6Gateway (Read or Write)
- cfgIPv6AutoConfig (Read or Write)
- cfgIPv6PrefixLength (Read or Write)
- cfgIPv6LinkLocalAddress (Read Only)
- cfgIPv6Address2 (Read Only)
- cfgIPv6Address3 (Read Only)
- cfgIPv6Address4 (Read Only)
- cfgIPv6Address5 (Read Only)
- cfgIPv6Address6 (Read Only)
- cfgIPv6Address7 (Read Only)
- cfgIPv6Address8 (Read Only)
- cfgIPv6Address9 (Read Only)
- cfgIPv6Address10 (Read Only)
- cfgIPv6Address11 (Read Only)
- cfgIPv6Address12 (Read Only)
- cfgIPv6Address13 (Read Only)
- cfgIPv6Address14 (Read Only)
- cfgIPv6Address15 (Read Only)
- cfgIPv6DNSServer1 (Read or Write)
- cfgIPv6DNSServersFromDHCP6 (Read or Write)
- cfgIpv6StaticLanNetworking
- cfgIPv6StaticEnable (Read or Write)
- cfgIPv6StaticAddress1 (Read or Write)
- cfgIPv6StaticGateway (Read or Write)
- cfgIPv6StaticPrefixLength (Read or Write)
- cfgIPv6StaticAutoConfig (Read/Write)
- cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)
- cfgIPv6StaticDNSServer1 (Read or Write)
- cfgIPv6StaticDNSServer2 (Read or Write)
- cfgIPv6DNSServer2 (Read or Write)
- cfgIPv6URL
- cfgIpmiSerial
- cfgIpmiSerialBaudRate (Read or Write)
- cfgIpmiSerialChanPrivLimit (Read or Write)
- cfgIpmiSerialConnectionMode (Read or Write)
- cfgIpmiSerialDeleteControl (Read or Write)
- cfgIpmiSerialEchoControl (Read or Write)
- cfgIpmiSerialFlowControl (Read or Write)
- cfgIpmiSerialHandshakeControl (Read or Write)
- cfgIpmiSerialInputNewLineSequence (Read or Write)
- cfgIpmiSerialLineEdit (Read or Write)
- cfgIpmiSerialNewLineSequence (Read or Write)
- cfgSmartCard
- cfgNetTuning
- cfgSensorRedundancy
- cfgVFlashSD
- cfgVFlashPartition
- cfgLogging
- cfgRacSecurity
- New Groups and Objects for iDRAC9
- Legacy and New Groups and Objects
- Error Codes
NonRAIDDiskCachePolicy = Not Applicable
OperationState = Not Applicable
PowerStatus = On
SecurityStatus = Not Capable
UsedRaidDiskSpace = 0.001 GB
T10PICapability = Not Capable
BlockSizeInBytes = 512
SystemEraseCapability = CryptographicErasePD
EncryptionCapability = Not Capable
CryptographicEraseCapability = Capable
EncryptionProtocol = None
PartNumber = CN0FJ9YXPESIT9AD010TA02
ForeignKeyIdentifier = null
RaidNominalMediumRotationRate = 0
Configuration
● To view the help details for a configuration command, run the following command:
racadm>> racadm storage help createvd
Storage configuration of hardware RAID connected to the system.
Usage:
racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-wp {wt|wb|
wbf}] [-rp {nra|ra|ara}]
[-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}]
-pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}]
[-name <VD name>] [-size <VD size>{b|k|m|g|t}] [-T10PIEnable]
--------------------------------------------------------------------------------
Options :
-rl : Set the RAID Level
r0 : RAID 0 - Striping
r1 : RAID 1 - Mirroring
r5 : RAID 5 - Striping with Parity
r6 : RAID 6 - Striping with Extra Parity
r10 : RAID 10 - Spanned Striping with Mirroring
r50 : RAID 50 - Spanned Striping with Parity
r60 : RAID 60 - Spanned Striping with Extra Parity
-wp {wt | wb | wbf} : Set the write policy to Write Through or Write Back or
Write Back Force
-rp {nra|ra|ara} : Set the read policy to No Read Ahead, Read Ahead, Adaptive
Read Ahead
-ss : Specify the stripe size to use
-pdkey:<PD FQDD list> : The PDs to use in the VD.
-dcp : Set the Disk Cache Policy in the VD
enabled : Enabled - Allow the disk to use it's cache
disabled : Disabled - Disallow the disk from using it's cache
default : Default - Use the default cache policy.
SAS Drives - Use Disabled by Default
SATA Drives - Use Enabled by Default
-name <VD name> : The name to give the VD
-size <VD size> : The size of the VD
b : Specify the size in bytes
k : Specify the size in kilobytes
m : Specify the size in megabytes
g : Specify the size in gigabytes
t : Specify the size in terabytes
-sc : Spandepth: Number of spans in a virtual disk
Note:
- This option is mandatory for hybrid raid level like RAID 10, RAID50 and RAID60.
- The default value is one for basic RAID levels.
- If RAID10 Uneven Span is Supported then for RAID10:
- -sc option will be optional.
- Will allow only 0 value for this option.
-T10PIEnable : To create a VD with PI
--------------------------------------------------------------------------------
Description :
Create a VD.
--------------------------------------------------------------------------------
142
RACADM Subcommand Details