Table 15. Configuration B (continued)
CPU Power
Dissipation /
GPU Power (4x)
2x 70 W 2x 85 W 2x 105 W 2x 125 W 2x 130 W 2x 140 W 2x 150 W 2x 165 W
250 W 27 26 26 25 25 24 23 22
225 W 29 28 28 27 27 26 25 24
200 W 30 30 30 30 29 28 27 26
Table 16. Configuration C
CPU Power
Dissipation /
GPU Power
(4x)
2x 70 W 2x 85 W 2x 105 W 2x 125 W 2x 130 W 2x 140 W 2x 150 W 2x 165 W
325 W 24 23 22 21 20 20 19 17
300 W 28 26 24 23 23 23 22 20
275 W 28 27 26 25 25 24 23 21
250 W 30 29 28 27 26 26 25 23
225 W 30 30 30 29 28 28 28 26
200 W 30 30 30 30 30 30 30 28
Table 17. Configuration G
CPU Power
Dissipation /
GPU Power
(4x)
2x 70 W 2x 85 W 2x 105 W 2x 125 W 2x 130 W 2x 140 W 2x 150 W 2x 165 W
325 W 23 22 20 19 18 18 18 17
300 W 25 24 22 21 21 20 19 18
275 W 27 26 23 23 23 22 21 20
250 W 28 27 25 25 25 24 23 22
225 W 30 29 27 27 27 26 25 24
200 W 30 30 29 29 29 28 27 26
Table 18. Configuration K
CPU Power
Dissipation /
NVLink SXM2
2x 70 W 2x 85 W 2x 105 W 2x 125 W 2x 130 W 2x 140 W 2x 150 W 2x 165 W
300W 25 24 22 21 20 19 18 18
Table 19. Configuration M
CPU Power
Dissipation /
NVLink SXM2
2x 70 W 2x 85 W 2x 105 W 2x 125 W 2x 130 W 2x 140 W 2x 150 W 2x 165 W
300W 24 24 23 23 22 22 20 20
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous
contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage
or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of
the customer.
Technical specifications