Owners Manual
Table Of Contents
- About Your System
- Accessing System Features during Startup
- Front-Panel Features and Indicators
- Hard-Drive Indicator Patterns
- Service Tag
- Back Panel Features and Indicators
- System-Board Assembly Configurations
- LAN Indicator Codes
- Power and System Board Indicator Codes
- Power Supply Indicator Codes
- BMC Heart Beat LED
- Post Error Code
- System Event Log
- Sensor Data Record
- Other Information You May Need
- Using the System Setup Program
- Removing and Installing System Components
- Safety Instructions
- Recommended Tools
- Opening and Closing the System
- Inside the System
- Cooling Fans
- Hard Drives
- Removing a 3.5-inch Hard-Drive Blank
- Installing a 3.5-inch Hard-Drive Blank
- Removing a 2.5-inch Hard-Drive Blank
- Installing a 2.5-inch Hard-Drive Blank
- Removing a Hard-Drive Carrier
- Installing a Hard-Drive Carrier
- Removing a Hard Drive from a Hard-Drive Carrier
- Installing a Hard Drive into a Hard-Drive Carrier
- Installing a 2.5” SSD into a 3.5” Hard-Drive Carrier
- Power Supplies
- System-Board Assembly
- Air Baffle
- Heat Sinks
- Processors
- Interposer Extender for 2U Node
- Expansion-Card Assembly and Expansion Card
- PCI-E Slot Priority
- RAID Card
- LSI 9265-8i Card
- LSI 9265-8i RAID Battery
- Riser Card
- Optional Mezzanine Cards
- Removing the LSI 2008 SAS Mezzanine Card
- Installing the LSI 2008 SAS Mezzanine Card
- Cable Routing for LSI 2008 SAS Mezzanine Card (1U Node)
- Cable Routing for LSI 2008 SAS Mezzanine Card (2U Node)
- Removing the 1GbE Mezzanine Card
- Installing the 1GbE Mezzanine Card
- Removing the 10GbE Mezzanine Card
- Installing the 10GbE Mezzanine Card
- Mezzanine-Card Bridge Board
- System Memory
- System Battery
- System Board
- Power Distribution Boards
- Middle Planes
- Direct Backplanes
- 2.5-inch Hard Drive Expander Configuration
- Front Panels
- Sensor Boards
- Removing the Sensor Board for 3.5” Hard-Drive System
- Installing the Sensor Board for 3.5” Hard-Drive System
- Cable Routing for Sensor Board and Front Panel for 3.5” Hard Drive System
- Removing the Sensor Board for 2.5” Hard-Drive System
- Installing the Sensor Board for 2.5” Hard-Drive System
- Cable Routing for Sensor Board and Front Panel for 2.5” Hard Drive System
- Troubleshooting Your System
- Minimum Configuration to POST
- Safety First – For You and Your System
- Installation Problems
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting the Video Subsystem
- Troubleshooting a USB Device
- Troubleshooting a Serial I/O Device
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supplies
- Troubleshooting System Cooling Problems
- Troubleshooting a Fan
- Troubleshooting System Memory
- Troubleshooting a Hard Drive
- Troubleshooting a Storage Controller
- Troubleshooting Expansion Cards
- Troubleshooting Processors
- IRQ Assignment Conflicts
- Jumpers and Connectors
- C6220 II System Board Connectors
- C6220 System Board Connectors
- Backplane Connectors
- Middle Plane Connectors
- Interposer Extender for 2U Node Connectors
- LSI 2008 SAS Mezzanine Card Connectors
- 1GbE Mezzanine Card Connectors
- 10GbE Mezzanine Card Connectors
- Power Distribution Board 1 Connectors
- Power Distribution Board 2 Connectors
- Sensor Board Connectors
- Jumper Settings
- Getting Help
- Index

150 | Using the System Setup Program
Table 2-3. The Power Management Settings
Setup Menu Setting
Maximum
Performance (48DB)
Energy Efficiency
(48DC)
Setup Page Setting Option
D4
Token
Option
D4
Token
Power
Management
Power
Management
Max.
Performance
021F Node
Manager
4800
Energy
Efficiency
Policy
Performance 48D0 Low
Power
48D2
Processor
Configuration
Active
Processor
Cores
All 026E 1/2 0233
/0232
Frequency Ratio
Auto
48C0
3
48C3
QPI Frequency
Auto
48C8
4.80GT/s
48C9
Turbo Mode
Enabled
01E8
Disabled
01EA
C State Disabled 024C Enabled 024B
C1E State
Disabled
02A2
Enabled
02A1
C6 State
Disabled
480A
Enabled
480B
C7 State Disabled 480E Enabled 480F
Direct Cache
Access
Enabled 48D4 Disabled 48D3
Hyper-
Threading
Technology
Enabled 00D1 Disabled 00D2
Adjacent Cache
Line Prefetch
Enabled 0172 Disabled 0171
Hardware
Prefetcher
Enabled 0174 Disabled 0173
DCU Streamer
Prefetcher
Enabled 02C5 Disabled 02C6
DCU IP
Prefetcher
Enabled
02CE
Disabled
02CF
Memory
Configuration
Memory
Frequency
Auto
4823
800 MHz
4824
Memory Turbo
Mode
Enabled
4821
Disabled
4820
Memory
Throttling Mode
Disabled
4828
Enabled
4829