Using the System Setup Program | 69
After reconnecting the console, if the display is abnormal it is
recommended that you reflash the screen by pressing the <Ctrl><R>.
The following are different modes for Console Redirection:
1. External serial port.
2. Internal serial connector as Serial Over LAN (SOL).
3. BMC SOL.
Enabling and Configuring Console Redirection
External Serial Port
To enable SOL feature in the external serial port mode, perform the
following steps:
1. Connect the serial cable to the serial port and host system. For
location of the serial port on the back panel, see Figure 1-14 item
8.
2. Enter the server BIOS setup screen.
3. Enter Set BMC LAN Configuration screen and verify the
following settings:
Remote Access: enabled
Serial port number: COM1
Serial Port Mode: 115200 8, n, 1
Flow Control: None
Redirection After BIOS POST: Always
Terminal Type: VT100
To do this, seeRemote Access Configuration” on page 110. Note
that the last four options need to sync with the host and client.
Internal Serial Connector as SOL
1. Connect the serial cable with internal serial connector and
host system. For the location of internal serial connector on
the system board, see Figure 5-1 item 15.
2. Enter the server BIOS setup screen.
3. Enter Set BMC LAN Configuration screen and verify the
following settings:
Remote Access: enabled