FILE LOCATION: D:\Projects\User BMC\BMC\C8220-C8220X_BMC_HOM_tp.fm Guide\Server\Dell\OOB\HOM\C8220-C8220X NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this publication is subject to change without notice. © 2013 Dell Inc.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_bk0TOC.fm Contents Intelligent Platform Management Interface . 5 . . . . . . . . . . . 5 . . . . . . . . . . . . . . . . . . . . 5 Baseboard Management Controller . Supported Platform . . . . . . . . . . . . 5 . . . . . . . . . . . . . . 6 BMC Key Features and Functions . Using the Web User Interface . Logging in to the Web User Interface . Remote Management Controller 7 . . . . . . . . . . .
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_bk0TOC.fm Using the Video Viewer . . . . . . . . . . . . . . . . . Video Viewer Menu . . . . . . . . . . . . . . . . . 52 . . . . . . . . . . . . . . 62 Extended Configuration Commands . . . . . . . . Threshold Settings and Converting Formulas . 4 Contents 49 . . . . . . . . . . IPMI 1.5/2.0 Commands Support List . OEM Commands Support List 48 . . . . .
Intelligent Platform Management Interface The Intelligent Platform Management Interface (IPMI) defines a set of standardized, message-based interfaces that monitor system hardware health (fan speed, temperature, voltage, power supply, and so on.), control system components, and store data about important system events in a system event log (SEL) for later examination. IPMI provides the foundation for remote platform management. NOTE: To learn more about IPMI, see intel.com/design/servers/ipmi/.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm • Platform Event Filtering (PEF) to take selected action for selected events • Chassis management, which includes power control, status report, front panel buttons, and LEDs control • PowerEdge C8220X compute sled management, which includes Xeon Phi 5110P/7110P MIC card and NPDB board NOTE: Make sure all cables are properly attached to the 5110/7110P MIC card and NPDB board.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Logging in to the Web User Interface Users must enter the PowerEdge C8220 and C8220X embedded server IP address or URL (default DHCP\static IP address) into the address bar of the web browser.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-1. Default User Name and Password Field Default User Name root Password root NOTE: The default username and password are in lowercase characters. It is advised to change the root password once you have logged in. Click the Help button on the top right corner for assistance. Click Logout to exit. The Remote Management Controller’s web UI is divided into two areas.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Remote Management Controller The Remote Management Controller menu provides general information about the server including the BMC firmware and network information. Administrators and operators can use this menu to check the sled server health and access all network configuration options.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Properties The Properties option enables you to view the remote sled server BMC firmware information. Table 1-2.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Chassis The Chassis option enables you to view a summary chassis information including LEDs and power supply status. Table 1-3.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Configuration The Configuration option enables you to view and set values for various system functions. Click on the Configuration option to expand the submenu items. • Network • Security • Users • Services • IPMI Network Select the Network submenu to view and configure the network setting parameters.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-4. Network Item Description General Settings Mode Select a network connectivity mode. Host Name Type the name of the BMC host server in this field. DNS Domain Name Type the domain name of the DNS server in this field. Network Interface Configuration Name Column Indicates the network interface name. iF Enabled Column Indicates the operational status of the NIC.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Security Select the Security submenu to view server certificate information. Secure server certificates ensure the identity of a remote system and ensure that information exchanged with the remote system cannot be viewed or changed by others. Users with administrator or operator privileges can create a Certificate Signing Request (CSR) and upload the file to a certifying authority. Table 1-5.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-5.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Users Select the Users submenu to view the list of users authorized to access the system. Administrators can grant any user permission privileges by clicking a user ID number. Table 1-6. Users Item Description Password Policy Check Enable Checkbox Enables you to improve the security of your passwords by enforcing strong password security policies.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-6. Users Item Description User ID Column Displays a list of users who can access this BMC If a privilege is assigned to a user, the user ID appears as a hyperlink.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Services Select the Services submenu to view the communication service parameters. Users with administrator or operator privileges can set up this service. Table 1-7. Services Item Description HTTP Port Number Port to use for HTTP-based communication. The default HTTP port number is 80. HTTPS Port Number Port to use for HTTPS-based communication. The default HTTPS port number is 443.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm IPMI Select the IPMI submenu to view the IPMI-based communication service parameters. Users with administrator or operator privileges can configure the IPMI settings. Table 1-8. IPMI Item Description IPMI Settings Enable IPMI Over LAN Enables or disables IPMI over LAN access. Channel Privilege Level Limit Select a user privilege level for IPMI over LAN access.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Sessions The Sessions option enables you to view sessions currently running on the system. Table 1-9. Sessions Item Description Session ID Column Shows the number of active sessions or session ID numbers. User Name Column Shows the login name of the user. IP Address Column Shows the IP address of the user.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Update The Update option enables users with administrator or operator privileges to update the sled server’s BMC firmware. The following data is included in the BMC firmware package: • Compiled BMC firmware code and data • Web-based user interface, JPEG, and other user interface data files • Default configuration files NOTE: The firmware update retains the current BMC settings. Table 1-10.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-10. Update Item Description Browse Button Use this button to navigate to the firmware file saved onto a media. Update Type Select a firmware update type. • Normal (default): Updates the firmware only when the BMC validates the target board, target product, and version number.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm 5 Click Update. When the update is completed, the remote system will reboots automatically. NOTE: When the firmware update is in process, the system will not be available to other users. Utilities The Utilities option enables users with administrator and operator privileges to remotely reboot or reset the BMC firmware. Table 1-11.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Server Information The Server Information menu enables users with administrator and operator privileges to remotely perform a power control operation on the server. The Server Information menu provides access to the following configuration options.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-12. Sensor Monitor Item Description General Settings Auto Refresh Interval Select a time interval (Never Auto-Refresh, Every 1 Minute, Every 5 Minutes) to automatically reload the page. Sensor Type Select a sensor type. • Voltages • Power supplies • Batteries • Fans • Temperatures Display Type Select the sensor display type.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-13. Voltages Sensor Readings Items Description General Settings For more information on this option, see Table 1-12. Probe List Status Column Indicates the voltage sensor status. Probe Name Column Shows the name of the voltage sensor. Typical voltage probes: • 12 V standby • 5 V standby • 5V • 3.3 V standby • 3.3 V NOTE: The 5 V and 3 V sensors are unavailable when powered off.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Power Supplies Select Power Supplies from the Sensor Type drop-down menu to view the status of the server chassis’s power supply. The power supplies are shared among all the sled servers in the server chassis. Click the Chassis option on the menu bar to view detailed information about the server chassis power supply. Table 1-14.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-14. Power Supplies Sensor Readings Item Input Wattage Column Description Shows the power supply peak watt. Maximum Wattage Column Shows the power supply maximum watt. Firmware Version Column Shows the firmware version. Refresh Button Use this button to refresh the power supply information.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-15. Power Units Sensor Readings Item Description Power Units Status NOTE: The two power units sensors can be used to analyze and convert SELs to human readable format. The description column will display them as Unavailable. Status Column Shows the power unit status. Probe Name Column Shows the name of the power unit sensor.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Batteries Select Batteries from the Sensor Type drop-down menu to view the status of the server system board battery. Table 1-16. Batteries Sensor Readings Item Description General Settings For more information on this option, see Table 1-12. Probe List 30 Status Column Shows the system board CMOS coin-cell battery status. Probe Name Column Shows the name of the battery sensor.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Fans Select Fans from the Sensor Type drop-down menu to view the status and readings of the server fan sensors. Table 1-17. Fans Sensor Readings Items Description General Settings For more information on this option, see Table 1-12. Probe List Status Column Shows fan sensor status. Probe Name Column Shows the fan sensor number.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-17. Fans Sensor Readings Items Upper Critical Column Description Shows the fan upper critical threshold. Upper Non-Recoverable Shows the fan upper non-recoverable threshold. Column Redundancy Status Status Column Shows the fan sensor status. Probe Name Column Shows the fan sensor number. Description Column Shows the presence of fan module.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-18. Temperature Sensor Readings Items Description Probe List Status Column Displays the status of the temperature sensor. Probe Name Column Displays the temperature sensor name.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-18. Temperature Sensor Readings Items Description Upper Non-Critical Column Displays the temperature sensor upper non-critical threshold. Upper Critical Column Displays the temperature sensor upper critical threshold. Upper Non-Recoverable Displays the temperature sensor upper non-recoverable Column threshold.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Power The Power option enables you to view the server’s power status. Click on the Power option to view the Control submenu. Control The Control submenu lets you view the server’s power status. Users with administrator and operator privilege can perform a power control operation on the server. Table 1-19.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm System Event Log The System Event Log menu enables users with administrator and operator privileges to view system event information such as event ID, time stamp, sensor name, sensor type, and description (Event Log button). Table 1-20. System Event Log Items Description Severity Column Indicates the severity level of the log entry.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-20. System Event Log Items Description Save Log Button Use this button to save system event logs. Refresh Button Use this button to refresh the system event log. Event Management The Event Management option enables users with administrator or operator privilege to configure the Platform Event Filter (PEF) filters, SNMP trap settings, and email notifications.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-21. Platform Event Filters Items Description Platform Event Filters (PEF) Action Global Control List Action Name Specify a PEF action with the occurrence of a specific event. • Reboot • Power Cycle • Power Off • Generate PET Platform Event Filters (PEF) List Global Alerting Enable Select to enable all PEF and email notification alerts.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-21. Platform Event Filters Items Description Apply Changes Button Use this button to apply the changes. NOTE: BMC event log “Processor #0x1c” or “Processor #0x1d” clarification: This event is generated from Intel CPU ME (Management Engine).
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-22. Trap Settings Items Send Test Trap Button Description Use this button to send a test trap to a corresponding email address. IPv6 Destination List Enable Checkbox Enables or disables an IPv6 destination address. You can enable up to four IPv6 destination addresses. IPv6 Address Configure up to four IPv6 addresses.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-23. Email Settings Items Description Sender Information From Specifies the sender’s address. The sender’s address must have the following requirements: • Can contain a combination of the following characters: • Upper and lowercase letters (A-Z, a-z) • Numbers (0-9) • Special characters (for example, /, =, -, _, +, !, #, $, %, etc.).
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-23. Email Settings Items 42 Description STARTTLS mode Select a Start Transport Layer Security (StartTLS) mode. SASL Mode Select a Simple Authentication and Security Layer (SASL) authentication mode. Apply Changes Button Use this button to apply the changes.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Serial Over LAN The Serial over LAN menu enables users with administrator and operator privileges to configure the Serial over LAN settings, select or change pertinent values for each attribute and save any changes. Table 1-24. Serial Over LAN Settings Items Description Enable Serial Over LAN Checkbox Enables or disables Serial over LAN (SOL) connection.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm vKVM & vMedia The vKVM & vMedia option enables the administrators to view and configure the virtual KVM and media settings and launch the Java KVM and VM console clients. Click on the vKVM & vMedia option to expand the submenu items. • Launch • Configuration Launch Select the Launch submenu to view and initiate console redirection. Table 1-25.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-25.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm To start a remote console session from the Virtual KVM and Media Launch window, click the Launch Java KVM Client or Launch Java VM Client button. This launches the redirection console via the JViewer Java applet. For further information on remote console sessions, see "Using the Video Viewer" on page 48.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-26. Virtual KVM and Media Configuration Items Preferred Client Type Description Select a client application to use for connecting to the KVM client. Virtual Media Configuration Enabled Enables or disables the virtual media. Encryption Enabled Enables or disables the virtual media encryption. Preferred Client Type Select a client application to use for connecting to the VM client.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Using the Video Viewer The Video Viewer provides a user interface between the management station and the managed server, allowing you to see the managed server's desktop and control its mouse and keyboard functions from your management station. When you connect to the remote system, the Video Viewer login screen prompts for the password.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Video Viewer Menu The Video Viewer menu provides access to additional functions, outlined in the following tables. Table 1-27. File Menu Items Menu Option Description Capture to Clipboard Captures the current remote system screen to save it to the clipboard. Exit Closes the Video Viewer window. Table 1-28.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-30. Tools Menu Items Menu Option Description Sessions Options Provides additional session viewer control adjustments. The General tab allows you to enable the keyboard pass through mode feature. Select Pass all keystrokes to target to pass your management station's keystrokes to the remote system.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-32. Help Menu Items Menu Option Description Contents and Index Opens the Video Viewer Help. About Displays the Video Viewer version information.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm IPMI 1.5/2.0 Commands Support List The IPMItool program provides a simple command-line interface for managing IPMI-enabled devices.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-33.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-34.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-35.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-37.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-39.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-41.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-43.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-45.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-47. Firmware Update Commands (NetFn: 08H) Command NetFn Firmware Update Phase 1 O/M Supported Firmware 10h O Yes Firmware Update Phase 2 Firmware 11h O Yes Get Firmware Update Status Firmware 12h O Yes Get Firmware Version Firmware 13h O Yes Set Firmware Update Status Firmware 16h O Yes Firmware Update Phase 3 Firmware 21h O Yes Table 1-48.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm OEM Commands Support List Extended Configuration Commands This section includes a brief list of the Extended Configurations Commands in the Dell DCS product specification. See the BMC Firmware Requirements for DCS/PE-C 1.02 documentation for more details. Table 1-49.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Response Data Byte Data Field 6 Data Offset - MSB 7 Bytes to read.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Byte 2 Data Field SC settings to be restored to default. FFh = Restore all SC settings to default. All other values are reserved. Response Data 1 Completion code. CCh = Restore to one or more of the configuration not supported. 2 Get Restore Status Command Byte Task ID. Use the Task ID to get the restore status.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Extended Configurations The following tables include the Extended Configuration IDs and commands. In the R/W column: • R = Read • W = Write • R/W = Read/Write NOTE: The strings in the table below are in P-String format. P-Strings are preceded by a length identifier. Table 1-50.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-51. Configuration ID = 03h, SOL Attribute ID Size Description R/W SOL Idle Timeout 1 2 R/W • Byte[1:2]: Define the inactivity timeout in minutes, 1-based, LSByte first. This parameter only applies to the IPMI over LAN session with SOL payload activated. • 0h: Session does not timeout and close due to inactivity. Default value is 01h.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-53. Configuration ID = 05h, Account Status Attribute ID Size Description R/W Number of User 1 1 Number of user created, including enabled and R disabled users. The count does not include USER ID1. Default value is 01h. Number of Enabled User 2 1 Number of enabled users. This count does not include USER ID1. Default value is 01h. R User Name 3 1..
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-54. Configuration ID = 06h, DNS Attribute ID Size Description R/W DNS Register BMC 4 1 R/W Enable registering the BMC host name to the DNS server (via DHCP Request Option 81h FQDN) • 0: FALSE (default) • 1: TRUE DNS BMC Host 5 Name 1.. 64 Specifies the DNS BMC host name. When the R/W DNS Register BMC is set to TRUE this parameter is read-only.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-55. Configuration ID = 0Ch, WEB Server Configuration Attribute ID Size Description R/W Web Server Enabled 1 1 R/W Disables or enables the BMC Web server. • 0: FALSE • 1: TRUE (default) Max Web Sessions 2 1 The maximum number of simultaneous sessions R allowed for this system. This field is READ-ONLY.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-56. Configuration ID = 0Eh, Firmware Log, Indexed Object Attribute ID Size Description R/W Entity 1 1 See the Firmware Information configuration. R Firmware Version 2 1.. 16 See the Firmware Information configuration. R Branch 3 1.. 16 See the Firmware Information configuration. R Build Information 4 1.. 16 See the Firmware Information configuration.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-57. Configuration ID = 0Fh, Firmware Information, Indexed Object Attribute ID Size Description R/W Firmware Version 5 1.. 16 A string containing the BMC firmware version. The firmware version is reading from IPMI Get Device ID command. The format of BMC FW Version string is ".", where major is one character and minor is two characters. R Branch 6 1..
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-58. Configuration ID = 10h, Firmware Update Attribute ID Remote Update 1 Enable Size Description R/W 1 R/W Allow firmware update via HTTP/FTP/TFTP server. • 0h: Disable • 1h: Enable (default) Protocol 2 1 Specified supported protocols. R • [7:3] - Reserved • [2] - HTTP • [1] - FTP • [0] - TFTP Default value is 07h. URI 3 1.. The URI of the image file.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-59. Configuration ID = 11h, Power Management Attribute ID Size Description Power Staggering AC Recovery 2 1 R/W This parameter is only effective if the Power Policy R/W is not set to always off. • 0x00: Immediate Power On (No Delay) (default) • 0x01: Auto (Random), the auto generated delay time must be in the range of Minimum Power On Delay and Maximum Power On Delay.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-60. Configuration ID = C0h, IPv6 Setting Attribute ID Size Description R/W IPv6 Enable 1 1 R/W IPv6Enable • 0: FALSE (default) • 1: TRUE IPv6 Address 2 1.. 40 IPv6 Address (Read only if the AutoConfig attribute is set to TRUE.) R/W IPv6 Gateway IP 3 Address 1..
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-61. Configuration ID = C1h, IPv6 Trap Setting, Idexed Object Attribute ID Size Description R/W IPv6 SNMP Trap Destination Setting 1 3 R/W IPv6 SNMP Trap Destination Address 2 • Byte 2: Alert ACK Timeout (See the IPMI spec.) • Byte 3: Retries (See the IPMI spec.) Number of IPv6 3 SNMP Trap Destination 76 • Byte 1:Destination Type (See the IPMI spec.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Threshold Settings and Converting Formulas The following table lists the system sensor’s threshold settings and formulas for converting the sensor readings. Table 1-62.
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm Table 1-63.