Owners Manual

Table 9. 1600 W AC/1600 W HVDC PSU indicators
Component Indicator Condition
AC power indicator Solid amber
Standby mode with Fan Lock for 15
seconds.
Standby mode with OTP range
Active mode with +12 V DC Fault
Active mode with Fan Lock for 15
seconds.
Solid green DC_OK (power good)
Blinking green Standby mode normal
Off Unit without AC power
Baseboard Management Controller (BMC) heart beat
LED
The system board provides BMC heart beat LED (CR17) for BMC debugging. The BMC heart beat LED is green. When the
power is connected, the LED is on. When BMC firmware is ready, the BMC heart beat LED blinks.
Figure 12. BMC heart beat LED on the C6320 system board
1. BMC heart beat LED
System configuration limitations by Intel Xeon
processor E5-2600 v3 and E5-2600 v4 product family
NOTE: Certain system hardware configurations may require reductions in the upper temperature limits.
NOTE: System performance may be impacted when operating above 30°C or with a fan fault.
Table 10. Configuration restrictions with Intel Xeon processor E5-2600 v3 and E5-2600 v4 product
family
Processor 3.5-inch hard drive chassis 2.5-inch hard drive chassis
55 W
E5-2630L v3
E5-2630L v4
No configuration restrictions No configuration restrictions
18 Dell PowerEdge C6320 product overview