CLI Guide

Table Of Contents
Table 36. Details of getsel (continued)
Display number of records in log.
racadm getsel -i
getsensorinfo
Table 37. Details of getsensorinfo
Description Displays the status for system sensors.
NOTE: For the Dell PowerEdge FX2 chassis with the FM120x4 server, the power-related information is
not displayed.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input -cCompact output format.
NOTE: Chassis Controller is supported only on PowerEdge FX2, and GPU sensors are displayed only on PowerEdge C4140
servers.
Example
racadm getsensorinfo
Sensor Type : POWER
Table 38. racadm getsensorinfo Sensor Type : POWER
<Sensor Name> <Status> <Type>
PS1 Status Present AC
PS2 Status AC-Lost AC
Sensor Type : TEMPERATURE
Table 39. Sensor Type : TEMPERATURE
<Sensor
Name>
<Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System
Board Inlet
Temp
Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System
Board
Exhaust
Temp
Ok
19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Sensor Type : FAN
Table 40. Sensor Type : FAN
<Sensor Name> <Status> <Reading> <lc> <uc> <PWM %>
System Board
Fan1 RPM
Ok 5880 RPM 600 RPM NA 21%
RACADM Subcommand Details 55