CLI Guide
Table 9. Details of the autoupdatescheduler command (continued)
● -l — Specifies the network share (NFS, CIFS, FTP, TFTP,HTTP, or HTTPS) location of the catalog
file. IPv4 and IPv6 addresses are supported.
● -f — Specifies the catalog location and the filename. If the filename is not specified, then the default
file used is catalog.xml.
NOTE: If the file is in a subfolder within the share location, then enter the network share location
in the –l option and enter the subfolder location and the filename in the –f option.
● -ph — Specifies the FTP/HTTP proxy host name.
● -pu — Specifies the FTP/HTTP proxy user name.
● -pp — Specifies the FTP/HTTP proxy password.
● -po — Specifies the FTP/HTTP proxy port.
●
-pt — Specifies the FTP/HTTP proxy type.
● -time — Specifies the time to schedule an autoupdate in the HH:MM format. This option must be
specified.
● -dom — Specifies the day of month to schedule an autoupdate. Valid values are 1–28, L (Last day) or
'*' (default — any day).
● -wom — Specifies the week of month to schedule an autoupdate. Valid values are 1–4, L (Last week)
or '*' (default — any week).
● -dow — Specifies the day of week to schedule an autoupdate. Valid values are sun, mon, tue, wed,
thu, fri, sat, or '*' (default — any day).
NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate
schedule. The * value for the options must be included within ' ' (single quotation mark).
● If the -dom option is specified, then the -wom and -dow options are not required.
● If the-wom option is specified, then the-dow is required and -dom is not required.
● If the-dom option is non-'*', then the schedule repeats by month.
● If the-wom option is non-'*', then the schedule repeats by month.
● If the-dom and -wom options are '*' and the -dow option is non-'*', then the schedule repeats by
week.
● If all the three -dom, -wom and -dow options are '*', then the schedule repeats by day.
● -rp — Specifies the repeat parameter. This parameter must be specified.
○ If the-dom option is specified, then the valid values for -rp are 1–12.
○ If the-wom option is specified, then the valid values for -rp are 1–52.
○ If the-dow option is specified, then the valid values for -rp are 1–366.
● -a — Applies reboot (1 — Yes, 0 — No). This option must be specified.
Example
Usage examples:
● To configure autoupdate feature settings.
○ For CIFS, run the command:
racadm autoupdatescheduler create -u domain/admin -p xxx -l //
1.2.3.4/share -f cat.xml -time 14:30 -wom 1 -dow sun -rp 1 -a 1
○ For NFS, run the command:
racadm autoupdatescheduler create -u nfsadmin -p nfspwd -l
1.2.3.4:/share -f cat.xml -time 14:30 -dom 1 -rp 5 -a 1
○
For FTP, run the command:
racadm autoupdatescheduler create -u ftpuser -p ftppwd -l
ftp.test.com -f cat.xml.gz -ph 10.20.30.40 -pu padmin -pp ppwd -po
8080 -pt http -time 14:30 -dom 1 -rp 5 -a 1
○ For HTTP, run the command:
racadm autoupdatescheduler create -u httpuser -p httppwd -l
http://test.com -f cat.xml -ph 10.20.30.40 -pu padmin -pp ppwd -
po 8080 -pt http -time 14:30 -dom 1 -rp 5 -a 1
34 RACADM Subcommand Details