Owners Manual

Table 13. Configuration Restrictions with Intel NVMe SSD AIC P4800X
TDP Watts
3.5-inch chassis 2.5-inch chassis
No-BP
Chassis
12x HDDs 8x HDDs 4x HDDs 24x HDDs 16x HDDs 8x HDDs 4x HDDs N/A
205 W Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
200 W Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
173 W Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
20
165 W Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
20
160 W Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
25
150 W Not
supported
Not
supported
Not
supported
Not
supported
20 20 20 25
140 W Not
supported
Not
supported
Not
supported
20 20 20 20 25
135 W Not
supported
Not
supported
Not
supported
20 20 20 20 25
130 W Not
supported
Not
supported
Not
supported
20 20 20 20 25
125 W Not
supported
Not
supported
Not
supported
20 25 25 25 30
115 W Not
supported
Not
supported
Not
supported
25 25 25 25 30
105 W Not
supported
Not
supported
Not
supported
25 25 25 25 30
85 W Not
supported
Not
supported
Not
supported
30 30 30 30 >35
70 W Not
supported
Not
supported
Not
supported
>35 >35 >35 >35 >35
Expanded operating temperature specifications
Table 14. Expanded operating temperature
Expanded operating temperature Specifications
Continuous operation 5°C40°C at 5% to 85% RH with maximum 29°C dew point.
NOTE: Outside the standard operating temperature
(10°C35°C), the system can operate continuously in
temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C-40°C, derate maximum
allowable temperature by 1°C per 175 m above 950 m (1°F
per 319 ft).
1% of annual operating hours 5°C45°C at 5% to 90% RH with maximum 29°C dew
point.
NOTE: Outside the standard operating temperature
(10°C35°C), the system can operate down to
Technical specifications 15