Table 20. Maximum continuous operating temperature for single processor with 2.5-inch direct drive
configuration for processor 1 - Air cooled (continued)
Processors TDP (W) Cores 6 x drives/
sled
4 x drives/
sled
2 x drives/ sled 1 x drive/ sled No BP
8352Y 205 32 30 30 35 35 35
6314U 205 32 30 30 35 35 35
8352S 205 32 30 30 35 35 35
6338 205 32 30 30 35 35 35
6330 205 28 30 30 35 35 35
6354 205 18 25 25 30 30 30
6346 205 16 25 25 30 30 30
8352V 195 36 30 30 30 30 35
6338N 185 32 35 35 35 35 35
6330N 165 28 35 35 35 35 35
NOTE: Additional thermal restrictions are required for PCIE > 25 Watts, 128GB LRDIMM and GPU configuration.
Table 21. Maximum continuous operating temperature for dual processor with 2.5-inch direct / 2.5-inch
NVMe drive configuration- Liquid cooled
Processors TDP (W) Cores 6 x drives/
sled
4 x drives/ sled 2 x drives/
sled
1 x drive/ sled No BP
8380 270 40 35 35 35 35 35
8368 270 38 35 35 35 35 35
8368Q 270 38 35 35 35 35 35
8360Y 250 36 35 35 35 35 35
8358 250 32 35 35 35 35 35
8358P 240 32 35 35 35 35 35
6348 235 28 35 35 35 35 35
8352Y 205 32 35 35 35 35 35
8352S 205 32 35 35 35 35 35
6338 205 32 35 35 35 35 35
6330 205 28 35 35 35 35 35
6354 205 18 35 35 35 35 35
6346 205 16 35 35 35 35 35
8352V 195 36 35 35 35 35 35
6338N 185 32 35 35 35 35 35
6330N 165 28 35 35 35 35 35
NOTE: Additional thermal restrictions are required for PCIE > 25 Watts, 128GB LRDIMM and GPU configuration.