Owners Manual

Next steps
1. Install the air shroud.
2. Follow the procedure listed in the After working inside your system.
Liquid cooling heat sink with liquid leak sensor
Removing the liquid cooling heat sink with liquid leak sensor cover
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If applicable, remove the air shroud.
4. If applicable, remove the standard heat sink.
NOTE: The heat sink and processor are too hot to touch for some time after the system has been powered down. Allow the
heat sink and processor to cool down before handling them.
Steps
1. Using a Phillips #1 screw driver, remove the screws that secure the liquid cooling heat sink with liquid leak sensor cover.
Figure 53. Removing the liquid cooling heat sink with liquid leak sensor cover
2. Remove the liquid cooling heat sink with liquid leak sensor cover.
NOTE:
If applicable, route and engage the liquid cooling heat sink with liquid leak sensor tubes with the groves in the
liquid cooling heat sink bracket.
Next steps
1. If you are removing a faulty liquid cooling heat sink with liquid leak sensor, replace the liquid cooling heat sink with liquid leak
sensor, if not, remove the processor.
2. If you are replacing the liquid cooling heat sink with a standard heat sink replace the heat sink, if not, remove the processor.
3. If applicable, replace the air shroud.
Installing and removing system components
57