iDRAC9 with Lifecycle Controller Version 3.30.30.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction............................................................................................................................... 34 New in this release.............................................................................................................................................................. 34 Supported RACADM Interfaces........................................................................................................................................
getractime............................................................................................................................................................................ 69 getremoteservicesstatus.................................................................................................................................................... 70 getsel.................................................................................................................................................
testtrap................................................................................................................................................................................149 testalert............................................................................................................................................................................... 149 traceroute.............................................................................................................................
cfgEmailAlert...................................................................................................................................................................... 168 cfgEmailAlertAddress (Read or Write)......................................................................................................................168 cfgEmailAlertEnable (Read or Write)........................................................................................................................
cfgRacVirtual...................................................................................................................................................................... 180 cfgVirMediaAttached (Read or Write)......................................................................................................................180 cfgVirtualBootOnce (Read or Write).........................................................................................................................
cfgThermal...........................................................................................................................................................................191 cfgThermalEnhancedCoolingMode (Read or Write)................................................................................................191 cfgIpmiSol............................................................................................................................................................................
cfgServerPowerLastDayMinPower (Read Only).....................................................................................................201 cfgServerPowerLastDayMinTime (Read Only)........................................................................................................201 cfgServerPowerLastDayMaxPower (Read Only)....................................................................................................201 cfgServerPowerLastDayMaxTime (Read Only).................................
cfgIPv6StaticAddress1 (Read or Write)....................................................................................................................212 cfgIPv6StaticGateway (Read or Write)....................................................................................................................212 cfgIPv6StaticPrefixLength (Read or Write).............................................................................................................212 cfgIPv6StaticAutoConfig (Read/Write).........
cfgLogging......................................................................................................................................................................... 223 cfgLoggingSELOEMEventFilterEnable (Read or Write)........................................................................................ 223 cfgRacSecurity..................................................................................................................................................................
System.LCD.Configuration (Read or Write)............................................................................................................ 238 System.LCD.vConsoleIndication (Read or Write)................................................................................................... 238 System.LCD.CurrentDisplay (Read Only)................................................................................................................ 239 System.LCD.LCDUserString (Read or Write)................
System. pcieSlotLFM.TargetLFM............................................................................................................................. 249 System.PCIeSlotLFM.PCIeInletTemperature (Read Only).................................................................................... 249 System.Power................................................................................................................................................................... 250 System.Power.Status (Read Only)..
System.Power.Supply.[i].Status (Read Only)..........................................................................................................263 System.Power.Supply.[i].Type (Read Only)............................................................................................................ 264 System.Power.Supply.[i].LineStatus (Read Only)...................................................................................................264 System.Power.Supply.[i].PMBusMonitoring (Read Only).......
System.ThermalSettings.MinimumFanSpeed (Read or Write)............................................................................. 275 System.ThermalSettings.MaximumPCIeInletTemperatureLimit (Read or Write)............................................... 276 System.ThermalSettings.MaximumPCIeInletTemperatureLimitSupport (Read Only)....................................... 276 System.ThermalSettings.SetAirTemperatureRiseLimit (Read or Write)..............................................................
iDRAC.ActiveDirectory.DomainController1 (Read or Write).................................................................................. 289 iDRAC.ActiveDirectory.DomainController2 (Read or Write)................................................................................. 289 iDRAC.ActiveDirectory.DomainController3 (Read or Write)................................................................................. 289 iDRAC.ActiveDirectory.Enable (Read or Write)............................................
iDRAC.IPMILan.Enable (Read or Write)................................................................................................................... 302 iDRAC.IPMILan.EncryptionKey (Read or Write)..................................................................................................... 303 iDRAC.IPMILan.PrivLimit (Read or Write)............................................................................................................... 303 iDRAC.IPMISerial....................................
iDRAC.IPv6.Address14 (Read or Write).................................................................................................................... 316 iDRAC.IPv6.Address15 (Read or Write).................................................................................................................... 316 iDRAC.IPv6.AutoConfig (Read or Write).................................................................................................................. 317 iDRAC.IPv6.DNS1 (Read or Write)...........
iDRAC.NIC.DNSDomainNameFromDHCP (Read or Write)...................................................................................329 iDRAC.NIC.DNSRacName (Read or Write)............................................................................................................. 329 iDRAC.NIC.DNSRegister (Read or Write)................................................................................................................330 iDRAC.NIC.Duplex (Read or Write)...........................................
iDRAC.RSM.RSMSetting (Read Only)..................................................................................................................... 342 iDRAC.Security.................................................................................................................................................................. 342 iDRAC.Security.CsrCommonName (Read or Write)...............................................................................................343 iDRAC.Security.
iDRAC. SupportAssist.DefaultPassword.................................................................................................................. 355 iDRAC. SupportAssist. DefaultProtocol................................................................................................................... 355 iDRAC. SupportAssist.DefaultShareName............................................................................................................... 356 iDRAC.SupportAssist.DefaultUserName............
iDRAC.USB.ConfigurationXML (Read or Write)..................................................................................................... 367 iDRAC.USB.ManagementPortMode (Read only)................................................................................................... 368 iDRAC.USB.PortStatus...............................................................................................................................................368 iDRAC.USB.ZipPassword (Read and Write)...............
iDRAC.VNCServer............................................................................................................................................................ 380 iDRAC.VNCServer.ActiveSessions (Read only)...................................................................................................... 380 iDRAC.VNCServer.Enable (Read or Write).............................................................................................................. 381 iDRAC.VNCServer.
BIOS.IntegratedDevices.UsbPorts (Read or Write)............................................................................................... 395 BIOS.EmbServerMgmt.....................................................................................................................................................395 BIOS.EmbServerMgmt.FrontLcd (Read or Write)................................................................................................. 395 BIOS.EmbServerMgmt.UserLcdStr (Read or Write)....
BIOS.ProcSettings.Proc1ControlledTurbo (Read or Write)...................................................................................408 BIOS.ProcSettings.Proc1Id (Read or Write)............................................................................................................408 BIOS.ProcSettings.Proc1L2Cache (Read or Write)............................................................................................... 409 BIOS.ProcSettings.Proc1L3Cache (Read or Write)..........................
BIOS.PxeDev1Settings.PxeDevnVlanEnDis (Read or Write)................................................................................. 422 BIOS.PxeDev1Settings.PxeDevnVlanId (Read or Write)........................................................................................423 BIOS.PxeDev1Settings.PxeDevnVlanPriority (Read or Write).............................................................................. 423 BIOS.SataSettings...........................................................................
BIOS.SerialCommSettings.ConTermType (Read or Write)................................................................................... 436 BIOS.SerialCommSettings.ExtSerialConnector (Read or Write).......................................................................... 437 BIOS.SerialCommSettings.FailSafeBaud (Read or Write)......................................................................................437 BIOS.SerialCommSettings.RedirAfterBoot (Read or Write)........................................
BIOS.SysSecurity.BiosUpdateControl (Read or Write)..........................................................................................452 BIOS.SysSecurity.IntelTxt (Read or Write)..............................................................................................................452 BIOS.SysSecurity.NmiButton (Read or Write)........................................................................................................452 BIOS.SysSecurity.PasswordStatus (Read or Write)................
FC.HBAConfig.PortLoginTimeout (Read or Write)................................................................................................ 465 FC.PortConfig....................................................................................................................................................................465 FC.PortConfig.DeviceName (Read Only)................................................................................................................ 466 FC.PortConfig.
NIC.FCoEConfiguration.................................................................................................................................................... 478 NIC.FCoEConfiguration.ConnectFirstFCoETarget (Read or Write).....................................................................478 NIC.FCoEConfiguration.BootOrderFirstFCoETarget (Read or Write)................................................................. 478 NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write)..........
NIC.IscsiInitiatorParams....................................................................................................................................................492 NIC.IscsiInitiatorParams.IscsiInitiatorChapId (Read or Write)............................................................................... 492 NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Read or Write).......................................................................... 492 NIC.IscsiInitiatorParams.
NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only)............................................................................. 506 NIC.VndrConfigGroup.FIPMacAddr (Read Only)................................................................................................... 506 NIC.VndrConfigGroup.FlexAddressing (Read Only)...............................................................................................506 NIC.VndrConfigGroup.iSCSIBootSupport (Read Only)....................................
Storage.Controller.T10PICapability (Read Only)..................................................................................................... 520 Storage.enclosure............................................................................................................................................................. 520 Storage.enclosure.AssetName.................................................................................................................................. 520 Storage.enclosure.
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for iDRAC for the Dell EMC servers. Topics: • • • • • • • • New in this release Supported RACADM Interfaces RACADM Syntax Usage Unsupported RACADM Subcommands Proxy parameters Other Documents You May Need Accessing documents from Dell support site Contacting Dell New in this release • • • • Added support for Windows Server 2019.
SSH, Telnet, or Remote RACADM racadm -r -u username -p password racadm -r -u username -p password getconfig -g -o
lrwxrwxrwx. 1 root root 27 Aug 28 13:31 /usr/lib64/libssl.so -> /usr/lib64/ libssl.so.1.0.1e lrwxrwxrwx. 1 root root 16 Oct 29 2014 /usr/lib64/libssl.so.10 -> libssl.so.1.0.1e -rwxr-xr-x. 1 root root 439912 Sep 27 2013 /usr/lib64/libssl.so.1.0.1e Accessing Indexed-Based Device Groups and Objects • To access any object, run the following syntax: device..[].
Option Description NOTE: If you delete a user account using the iDRAC web interface and then use RACADM to create a new account with the same user name, you are not prompted to enter a password. However, you must manually provide a password for the account to be able to log into iDRAC using that account. -p Specifies the password used to authenticate the command transaction. If the -p option is used, the -i option is not allowed.
• Example 3: racadm> getl racadm> getled or LEDState: Not-Blinking • Example 4: racadm>> get bios.uefiBootSettings BIOS.UefiBootSettings BIOS.UefiBootSettings.UefiBootSeq BIOS.UefiBootSettings.UefiPxeIpVersion NOTE: In the RACADM autocomplete mode, certain RACADM commands may not be listed inline with the platforms. In such scenarios, execute the RACADM command in the normal execution mode.
The valid lifecyclecontroller.lcattributes HTTP/HTTPS proxy parameters are: • • • • • UserProxyUserName UserProxyPassword UserProxyServer UserProxyPort UserProxyType To view the list of proxy attributes, use racadm get lifecycleController.lcAttributes. NOTE: Squid proxy configuration is not supported to access HTTP/HTTPS shares. Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at www.dell.com/esmmanuals.
• • Dell Client Command Suite • Connections Client Systems Management 4. To view a document, click the required product version. Using search engines: • Type the name and version of the document in the search box. Contacting Dell NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options.
2 RACADM Subcommand Details This section provides detailed description of the RACADM subcommands including the syntax and valid entries. Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands help and help subcommand arp autoupdatescheduler bioscert cd cd..
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ping ping6 RACADM Proxy racdump racreset racresetcfg recover remoteimage rollback sensorsettings serveraction set setled setniccfg sshpkauth sslcertdownload sslcertupload sslcertview sslcertdelete sslcsrgen sslkeyupload sslresetcfg storage SupportAssist swinventory switchconnection systemconfig systemerase systemperfstatistics techsupreport testemail testtrap testalert traceroute traceroute6 update usercertupload usercertview
• • • • • & (ampersand) > (greater than) < (less than) # (pound) ASCII code 32 (space) There are different escaping rules for double quotation marks. For using double quotation marks: The following characters must be escaped by prepending a backward slash: • • • $ (dollar sign) " (double quotation marks) ` (back quotation marks) help and help subcommand Table 3.
Table 5. Details of output Address HW Type HW Address Mask Device 192.168.1.1 Ether 00:0d:65:f3:7c:bf C eth0 autoupdatescheduler Table 6. Details of the autoupdatescheduler command Description You can automatically update the firmware of the devices on the server. To run this subcommand, you must have the Server Control privilege. NOTE: • The autoupdatescheduler subcommand can be enabled or disabled. • • Lifecycle Controller and CSIOR may not be enabled to run this subcommand.
• • -wom — Specifies the week of month to schedule an autoupdate. Valid values are 1–4, L (Last week) or '*' (default — any week). -dow — Specifies the day of week to schedule an autoupdate. Valid values are sun, mon, tue, wed, thu, fri, sat, or '*' (default — any day). NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate schedule. The * value for the options must be included within ' ' (single quotation mark).
• To clear and display AutoUpdateScheduler parameter: racadm autoupdatescheduler clear RAC1047: Successfully cleared the Automatic Update (autoupdate) feature settings bioscert Table 7. Details of the bioscert subcommand Description Allows you to • • • • • Synopsis • View the installed Secure Boot Certificates. To view, you must have the Login privilege Export the Secure Boot Certificate to a remote share or local system.
Example • • • • -f—Specifies the file name of the exported Secure Boot Certificate. -l—Specifies the network location to where the Secure Boot Certificate file must be exported. -u—Specifies the username for the remote share to where the Secure Boot Certificate file must be exported. -p—Specifies the password for the remote shre to where the Secure Boot Certificate file must be exported. • To view the installed Secure boot Certificates.
• To delete an installed KEK Secure Boot Certificate racadm bioscert delete -t 3 -k 0 -v 416e3e4a6722a534afba9040b6d6a69cc313f1e48e7959f57bf248d543d00245 • To delete an installed DBX Secure Boot Certificate of HASH type SHA-256 racadm bioscert delete -t 3 -k 1 -v 416e3e4a6722a534afba9040b6d6a69cc313f1e48e7959f57bf248d543d00245 • To delete all the installed KEK Secure Boot Certificates racadm bioscert delete --all • To restore the installed KEK Secure Boot Certificates racadm bioscert restore -t 1 •
• • Input: racadm/power> cd.. Output: system>> • Example 2: To traverse back from system object to the prompt: Input: racadm/system> cd.. Output: • • racadm>> clearasrscreen Table 10. Details of the clearasrscreen attribute Description Clears the last crash (ASR) screen that is in memory. For more information, see "Enabling Last Crash Screen" section in the iDRAC User’s Guide. NOTE: To run this subcommand, you must have the Clear Logs permission.
closessn Table 12. Details of closessn Description Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command. To run this subcommand, you must have the Administrator permission. NOTE: This subcommand ends all the sessions other than the current session.
NOTE: This subcommand is deprecated. For viewing the configuration objects and its values, use set subcommand. For more information, see iDRAC RACADM CLI Guide available at www.dell.com/ idracmanuals . Synopsis • racadm config -g -o
• Configure a RAC from a configuration file: racadm config -f config.txt • Configure a RAC from a configuration file and continue if a group fails to get configured: racadm set -f config.txt --continue coredump Table 15. Details of coredump Description Displays detailed information related to any recent critical issues that have occurred with iDRAC. The coredump information can be used to diagnose these critical issues.
diagnostics Table 17. Details of diagnostics Description Collects and exports remote diagnostics report from iDRAC. The results of the latest successfully run remote diagnostics are available and retrievable remotely through an NFS, CIFS, HTTP, or HTTPS) share.
• To export a remote diagnostics report to the HTTP share: racadm diagnostics export -f diags.txt -u httpuser -p httppwd -l http:// test.com • To export a remote diagnostics report to the HTTPS share: racadm diagnostics export -f diags.txt -u httpsuser -p httpspwd -l https://test.com • To export a remote diagnostics report to a local share: racadm diagnostics export -f diags.txt driverpack Table 18. Details of driverpack Description Installs the driver pack for the operating system.
eventfilters Table 19. Details of eventfilters Description Displays the list of event filter settings. To use this subcommand with the set and test option, you must have the Administrator privilege.
• • • • • idrac.alert.all idrac.alert.audit idrac.alert.audit.lic idrac.alert.audit.warning idrac.alert.audit.lic.critical This command does not support setting the proxy parameters if the share location (-l) is HTTP/HTTPS. For more information, see Proxy parameter section.
• Configure using subcategory and severity as parameters. For example, all information events under the licensing subcategory in the audit category are assigned power off as action and all notifications are disabled: racadm eventfilters set -c idrac.alert.audit.lic.info -a poweroff -n none • Configure the event generation interval for temperature statistics. racadm eventfilters set -c idrac.alert.system.tmps.
Synopsis racadm frontpanelerror show racadm frontpanelerror hide Input • • Example show — to view the errors currently being displayed on the LCD screen. hide — to hide the errors currently being displayed on the LCD screen. • racadm frontpanelerror show Front Panel Error—Show Enabled. • racadm frontpanelerror hide Front Panel Error—Hide Enabled. fwupdate Table 23. Details of fwupdate Description Allows you to update the firmware. You can: • • • • Check the firmware update process status.
• -g—The get option instructs the firmware to get the firmware update file from the TFTP server. Specify the a -u, and —d options. In the absence of the —a option, the defaults are read from properties in the group cfgRemoteHosts, using properties cfgRhostsFwUpdateIpAddr and cfgRhostsFwUpdatePath. • -p—The -p, or put, option is used to update the firmware file from the managed system to iDRAC. The -u option must be used with the -p option.
FW Update Method iDRAC on Blade Servers iDRAC on Rack and Tower Servers Remote RACADM-FTP Yes Yes Firmware RACADM-TFTP Yes Yes Firmware RACADM-FTP Yes Yes get Table 25. Details of get Description Displays the value of one or more objects. The get subcommand has two forms. • • Displays the value of a single object. Exports the value of multiple objects to a file.
Multi-object Get racadm get -f racadm get -f -t xml -l [--clone | --replace ] [-includeph] racadm get -f -t xml -l -c [,*] racadm get -f -t xml -u -p -l -c racadm get -f -t xml -l -c racadm get -f -t xml -u -p -l [--clone | --replace ] [--includeph] racadm get -f -t xml -u -p -l <
• • • • --clone—Gets the configuration .xml files without system-related details such as service tag. The .xml file received does not have any virtual disk creation option. --replace—Gets the configuration .xml files with the system-related details such as service tag. -c—Specifies the FQDD or list of FQDDs separated by ',' of the components for which the configurations should be exported. If this option is not specified, the configuration related to all the components are exported.
• Export the JSON configuration of the iDRAC component to FTP share. racadm get -f file -t json -u username -p password -l ftp://192.168.10.24/ • Export the xml configuration of the iDRAC component to TFTP share. racadm get -f file -t xml • -l tftp://192.168.10.24/ Export the JSON configuration of the iDRAC component to TFTP share. racadm get -f file -t json -l ftp://192.168.10.24/ • Export the xml configuration of the iDRAC component to a CIFS share.
Synopsis racadm getconfig -f racadm getconfig -g [-i ] racadm getconfig -u racadm getconfig -h racadm getconfig -g -o [-i index] Input • -f — The -f option directs getconfig to write the entire iDRAC configurations to a configuration file. This file can be used for batch configuration operations using the config subcommand. NOTE: This option is supported only on remote interfaces.
cfgUserAdmin cfgUserAdminUserName Example • Displays the configuration properties (objects) that are contained in the group cfgLanNetworking. racadm getconfig -g cfgLanNetworking • Saves all group configuration objects from iDRAC to myrac.cfg. racadm getconfig -f myrac.cfg If you do not configure the following key attributes in their respective groups for a particular index, the groups are not saved in to the file. This is applicable for all the index groups.
gethostnetworkinterfaces Table 28. Details of gethostnetworkinterfaces Description Displays host network interface details. NOTE: To run this subcommand, you must have iDRAC Service Module installed on the server operating system. Synopsis racadm gethostnetworkinterfaces racadm gethostnetworkinterfaces Examples • To display the details of all the network interfaces on the server.
Output Example • • LED is blinking LED is not-blinking racadm getled LED State : Blinking racadm getled LED State : Not-Blinking getniccfg Table 30. Details of getniccfg Description Synopsis Displays the current and static NIC settings for iDRAC. racadm getniccfg Input Output The getniccfg subcommand displays an appropriate error message if the operation is not successful. Otherwise, the output is displayed in the following format: Table 31.
IP Address 13 =:: IP Address 14 =:: IP Address 15 =:: LOM Status: NIC Selection =dedicated Link Detected =Yes Speed =1Gb/s Duplex Mode =Full Duplex Active NIC =Dedicated Static IPv4 settings: Static IP Address =10.94.227.207 Static Subnet Mask =255.255.255.0 Static Gateway =10.94.227.1 Static IPv6 settings: Static IP Address 1 =:: Static Prefix Length =64 Static Gateway =:: NOTE: IPv6 information is displayed only if IPv6 is enabled in iDRAC.
Output Example SeqNumber = 286 Message ID = USR0005 Category = Audit AgentID = RACLOG Severity = Information Timestamp = 2017-05-15 06:25:27 Message = Login failed from processdisco06a: 192.168.0 Message Arg 1 = processdisco06a Message Arg 2 = 10.92.68.245 FQDD = iDRAC.Embedded.
getremoteservicesstatus Table 34. Details of getremoteservicesstatus Description Displays the status of a system.
Example • Display entire log. racadm getsel • Display number of records in log. racadm getsel -i getsensorinfo Table 36. Details of getsensorinfo Description Displays the status for system sensors. NOTE: For the Dell PowerEdge FX2 chassis with the FM120x4 server, the power-related information is not displayed. Synopsis Input • racadm getsensorinfo • racadm getsensorinfo -c -c—Compact output format.
System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0% System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144% System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152% Sensor Type : VOLTAGE Table 40. Sensor Type : VOLTAGE CPU1 VCORE PG Ok Good NA NA System Board 3.3V PG Ok Good NA NA System Board 5V AUX PG Ok Good NA NA CPU1 M23 VPP PG Ok Good NA NA System Board 1.
Table 41. Sensor Type : CURRENT [R/W] [R/W] PS1 Current 1 Ok 0.4 Amps NA NA 0 Amps [N] 0 Amps [N] System Board Pwr Consumption Ok 56 Watts NA 1386 Watts 0 Watts [N] 1260 Watts [N] Sensor Type : PROCESSOR Table 42. Sensor Type : PROCESSOR CPU1 Status Ok Presence Detected NA NA CPU2 Status N/A Absent NA NA Sensor Type : MEMORY Table 43.
DIMM B12 N/A Absent NA NA Sensor Type : Chassis Controller Table 44.
System Board PS Redundancy Disabled PSU Sensor Type : SYSTEM PERFORMANCE Table 49. Sensor Type : SYSTEM PERFORMANCE [R/W] [R/W] System Board CPU Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] System Board IO Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] System Board MEM Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] System Board SYS Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y] getssninfo Table 50.
Synopsis racadm getsvctag Output Any system tag as applicable. Example • Display the service tag of the host system. racadm getsvctag getsysinfo Table 53. Details of getsysinfo Description Displays information related to iDRAC, managed system, and watchdog configuration. NOTE: The hostname and OS Name fields in the getsysinfo output display accurate information only if the OpenManage Server Administrator (OMSA) is installed on the managed system.
Current IP Address 6 Current IP Address 7 Current IP Address 8 Current IP Address 9 Current IP Address 10 Current IP Address 11 Current IP Address 12 Current IP Address 13 Current IP Address 14 Current IP Address 15 DNS Servers from DHCPv6 Current DNS Server 1 Current DNS Server 2 = = = = = = = = = = = = = :: :: :: :: :: :: :: :: :: :: Disabled 2011:de11:bdc:192::67/64 :: System Information: System Model System Revision System BIOS Version Service Tag Express Svc Code Host Name OS Name OS Version Power S
• • -c — Specifies the number of records to display. -s — Specifies the starting record to display. Output The default output display shows the record number, timestamp, source and description. The timestamp begins at midnight, January 1 and increases until the system starts. After the system starts, the system’s timestamp is used. Example • Display entire log racadm gettracelog • Display number of records in log racadm gettracelog -i Total Records: 228 getversion Table 55.
server-9 1.0.5 PowerEdgeM520 racadm getversion Bios Version = 2.0.18 iDRAC Version = 2.00.00.00 Lifecycle Controller Version = 2.00.00.00 racadm getversion -b Table 57. Details of racadm getversion -b server-1 1.6.0 PowerEdgeM520 server-2 6.3.0 PowerEdgeM610x server-4 7.0.0 PowerEdgeM710HD server-5 6.3.0 PowerEdgeM710 server-7 1.7.1 PowerEdgeM620 server-9 1.7.1 PowerEdgeM520 Table 58.
GroupManager Table 59. Details of GroupManager Description Allows you to: • • • Delete the group from the group manager. Remove the iDRAC from group by itself by using admin previleges. Join the group using administrator privileges. NOTE: This subcommand is supported only on iDRAC9. Synopsis • To delete the group from the group manager. groupmanager delete –g • To remove the iDRAC from group by itself by using administrator privileges.
• • • -u — Username of the remote share to where the file must be exported. Specify user name in a domain as domain/username -p — Password for the remote share to where the file must be exported. -l — Network share location to where the Hardware Inventory must be exported. Examples • To get the hwinventory, run the following command: racadm hwinventory [InstanceID: DIMM.Socket.
PrimaryStatus = OK ManufactureDate = Mon Mar 13 07:00:00 2017 UTC Model = DDR4 DIMM PartNumber = 18ASF2G72XF12G6V21AB SerialNumber = 1648DCC4 Manufacturer = Micron Technology BankLabel = A Size = 16384 MB CurrentOperatingSpeed = 2133 MHz Speed = 2666 MHz MemoryType = DDR-4 DeviceDescription = DIMM A7 FQDD = DIMM.Socket.A7 InstanceID = DIMM.Socket.
Slot Length: Bus Number: DeviceNumber: Function Number: Last Update Time: Last System Inventory Time: ProductName: WWN: VirtWWN: WWPN: VirtWWPN: Family Version: Controller BIOS Version: EFI Version: Max Bandwidth: Min Bandwidth: FCoE WWNN: Vendor Name: Number of PCI-e Functions Supported per Port: Number of PCI-e Functions Currently Enabled per Port: Family Driver Version: Protocol: Link Duplex: Link Speed: Auto Negotiated: Transmit Flow Control: Receive Flow Control: Media Type: NIC Mode: FCoE Offload Mode
TX Bandwidth Control Maximum: TX Bandwidth Control Minimum: • Not Capable Not Capable To export the inventory to a remote CIFS share, type the following command: racadm hwinventory export -f Myinventory.xml -u admin -p xxx -l //1.2.3.4/share • To export the inventory to a remote NFS share, type the following command: racadm hwinventory export -f Myinventory.xml -u admin -p xxx -l 1.2.3.
PCI Device: PCI Function: Vendor Name: Device Name: 2001000E1E091075 WWN: VirtWWN: WWPN: VirtWWPN: Chip Type: Family Version: EFI Version: OS Driver Version: First FC Target WWPN: First FC Target LUN: Second FC Target WWPN: Second FC Target LUN: Hard Zone Address: Hard Zone Enable: FC Tape Enable: Loop reset Delay: Frame Payload Size : Fabric Login Retry Count: Fabric Login Timeout: Port Login Retry Count: Port Login Timeout: Port Down Retry Count: Port Down Timeout: Link Down Timeout: Port Number: Port Spe
inlettemphistory Table 63. Details of inlettemphistory Description Displays the average and the peak temperatures during the last hour, day, week, month, or year. Also Exports the inlet temperature history data file. The file can be exported to a remote file share, local file system, or the management station. NOTE: For FM120x4 systems, this subcommand provides the historical data for system board temperature.
• Export the log to management station using Remote RACADM. racadm -r 1.2.3.4 -u user -p xxx inlettemphistory export -f Mylog.csv -t csv • View the inlet temperature history. racadm inlettemphistory get Duration Above Warning Threshold as Percentage = 0.0% Duration Above Critical Threshold as Percentage = 0.0% • Average Temperatures Last Hour = 23C ( 73.4F Last Day = 24C ( 75.2F Last Week = 24C ( 77.0F Last Month = 25C ( 77.0F Last Year = 23C ( 73.
where valid options are -i and --all. racadm jobqueue create [-r ] [-s ] [-e ] racadm jobqueue create [-r ] [-s ] [-e ] [--realtime] Input • -i — Specifies a job ID that is displayed or deleted. NOTE: The value JID_CLEARALL will force delete all the possible jobs in the queue. • • • --all — The job IDs that are not applicable are deleted. -fqdd — Specifies an FQDD for which a job should be created.
• Create a real time configuration job for the specified RAID controller. racadm jobqueue create RAID.Integrated.1-1 -s TIME_NOW --realTime RAC1024: Successfully scheduled a job. Verify the job status using "racadm jobqueue view -i JID_xxxxx" command. Commit JID = JID_927008261880 krbkeytabupload Table 65. details of krbkeytabupload Description Uploads a Kerberos keytab file to iDRAC. To run this subcommand, you must have the Server Control privilege.
Synopsis racadm lclog comment edit –q -m racadm lclog view -i -a -c -s -b -q -n -r -e racadm lclog export -f -u -p -l racadm lclog export -f -u -p -l --complete racadm
• • • • • • • • • • -r—Displays events that have occurred after this time. The time format is yyyy-mm-dd HH:MM:SS. The time stamp must be provided within double quotation marks. -e—Displays events that have occurred before this time. The time format is yyyy-mm-dd HH:MM:SS. The time stamp must be provided within double quotation marks. -f —Specifies the file location and name where lifecycle log is exported. -a —Specifies the FTP Server IP address or FQDN, user name, and password.
• Display all the available records from the active Lifecycle log. racadm lclog view NOTE: If output is not returned when this command is used remotely, then retry increasing the remote RACADM timeout value. To increase the timeout value, run the command racadm set iDRAC.Racadm.Timeout . Alternatively, you can retrieve few records. • Add a comment to record number 5 in the Lifecycle log. racadm lclog comment edit –q 5 –m “This is a test comment.” • Add a worknote to the Lifecycle log.
• Export the complete Lifecycle Log in gzip format to a remote HTTPS share racadm lclog export -f log.xml.gz -u httpsuser -p httpspwd -l https:// test.com • Export the Life Cycle Log to a remote HTTP share racadm lclog export -f Mylog.xml -u httpuser -p httppwd -l http://test.com • Export the Life Cycle Log to a remote HTTPS share racadm lclog export -f Mylog.xml -u httpsuser -p httpspwd -l https:// test.com NOTE: Squid proxy configuration is not supported to access http/https shares.
• View all License Information on System. $racadm license view iDRAC.Embedded.1 Status = OK Device = iDRAC.Embedded.1 Device Description = iDRAC Unique Identifier = H1VGF2S License #1 Status = OK Transaction ID = 5 License Description = iDRAC Enterprise License License Type = PERPETUAL Entitlement ID = Q3XJmvoxZdJVSuZemDehlcrd License Bound = H1VGF2S Expiration = Not Applicable • Import a new license to a specific device in a known location. $racadm license import -f license.
• Export license to a CIFS share specifying the entitlement ID, in this case abcdxyz. racadm license export -u admin -p passwd -f License.xml -l //192.168.0/licshare -e abcdxyz racadm license export -u httpuser -p httppwd -f License.xml -l http://test.com -e abcdxyz racadm license export -u httpsuser -p httpspwd -f License.xml -l https://test.com -e abcdxyz • Export license to a CIFS share specifying the FQDD.
• racadm nicstatistics • racadm hwinventory NIC.Integrated.
ping Table 70. Details of ping Description Verifies if the destination IP address is reachable from iDRAC with the current routing-table contents. A destination IP address is required. Based on the current routing-table contents, an ICMP echo packet is sent to the destination IP address. To run this subcommand, you must have the Debug privilege. Synopsis Input Output racadm ping — The IP address of the remote endpoint to ping. PING 192.168.0 (192.168.
Synopsis Local RACADM proxy usage racadm --proxy Remote RACADM proxy usage racadm -u -p -r --proxy NOTE: • • The attribute racadm getconfig -g cfgractuning -o cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC. The attribute racadm get system.ChassisControl.ChassisManagementMonitoring attribute must be enabled in iDRAC. --proxy must be entered at the end of the command.
racdump Table 74. Details of racdump Description Provides a single command to get dump, status, and general iDRAC board information. To run this subcommand, you must have the Debug permission. • • • • • • General System/RAC Information Coredump Information Network Interface Statistics Session Information Process Information RAC Firmware Build Log NOTE: The RAC debug logs are not part of Local and Remote RACADM.
[ksoftirqd/0] 6 root 0 SW [watchdog/0] 7 root 0 SW< [khelper] 8 root 0 SW [kdevtmpfs] 9 root 0 SW< [netns] 153 root 0 SW [sync_supers] 155 root 0 SW [bdi-default] 157 root 0 SW< [kblockd] 166 root 0 SW [khubd] 16233 root 40916 S racadm racdump 16246 root 3824 S sh -c /bin/ps 16247 root 3828 R /bin/ps 26851 root 0 SW [kworker/u:3] =============================================================================== RAC Firmware Build Log =============================================================================
Input Example • racadm racresetcfg -f • racadm racresetcfg [-all] • racadm racresetcfg [-rc] • • • -f—Force racresetcfg. If any vFlash partition creation or formatting is in progress, iDRAC returns a warning message. You can perform a force reset using this option. -all—Discard all settings and reset user to shipping value. -rc—Discard all settings and reset user to default user name and password.
RAC1234: Recovery operation initiated successfully. Check the Lifecycle logs for the status of the operation by running RACADM command "racadm lclog view". remoteimage Table 78. Details of remoteimage Description Connects, disconnects, or deploys a media file on a remote server. To run this subcommand, you must log in with virtual media privilege for iDRAC.
• Deploy a remote image on iDRAC NFS Share. racadm remoteimage -c -u root -p password -l '192.168.1.113:/opt/nfs/ OM840.iso • Deploy a remote image on iDRAC HTTP Share. racadm remoteinage -c -u "user" -p "xxx" -l http://shrloc/foo.iso • Deploy a remote image on iDRAC HTTPS Share. racadm remoteinage -c -u "user" -p "xxx" -l https://shrloc/foo.iso NOTE: -p and -u options are not mandatory in case of HTTP/HTTPS based remoteimage commands. rollback Table 79.
the sensor thresholds can be configured. Replace the field with the corresponding sensor FQDD that needs a threshold configuration. -level — threshold level for the sensor setting. Values are Max or Min. • Examples To set the minimum noncritical threshold level for a power sensor type. racadm sensorsettings set iDRAC.Embedded.1#SystemBoardCPUUsage -level Max 95 NOTE: The entered value must be lesser or higher than the sensor critical threshold limit. serveraction Table 81.
set Table 82. Details of set Description Modifies the value of configuration objects on a component. The Set sub-command has two forms: • • The modification of a single object to a new value specified in the command line. The modification of multiple objects to new values using a configuration file. It supports multi-object value import from two configuration file formats.
• Configure a RAC from an XML configuration file located on a remote NFS share racadm set -f -t xml -l 10.1.2.3:/myshare • Configure a RAC from an XML configuration file located on a remote HTTP share. racadm set -f -t xml -u -p -l http:// test.com/myshare • Configure a RAC from an XML configuration file located on a remote HTTPS share. racadm set -f -t xml -u -p -l https://test.
NOTE: The –b, -w, –s, and --preview options are applicable only with –f option. • -b — . Specifies the type of shutdown for the system after a file import operation completes. The parameters are Graceful, Forced, and NoReboot for graceful shutdown, forced shutdown, and no reboot respectively. If -b is not specified, graceful shutdown is taken as the default except as noted above for files containing new values for immediate application-capable s.
• Configure several BIOS settings, create a job to initiate application of new values, reboot the system, then wait for the job to complete. racadm racadm racadm racadm • • set BIOS.SysProfileSettings.ProcTurboMode Disabled set BIOS.ProcSettings.ProcVirtualization Enabled set BIOS.ProcSettings.ControlledTurbo Enabled jobqueue create BIOS.Setup.
• Configure a RAC from an XML configuration file located on a remote TFTP share. racadm set -f myfile.xml -t xml -l tftp://192.168.10.24/ • Configure a RAC from a JSON configuration file located on a remote TFTP share. racadm set -f myfile.xml -t json -l tftp://192.168.10.24/ • Configure a RAC from an XML configuration file located on a remote HTTP share. racadm set -f myfile.xml -t xml -u httpuser -p httppwd -l http://test.
setniccfg Table 84. Details of setniccfg Description Sets the iDRAC IP address for static and DHCP modes. To run this subcommand, you must have the Configure iDRAC privilege. NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Input • racadm sshpkauth -v -i svcacct -k all| • racadm sshpkauth -d -i svcacct -k all| • • • • • • -i — Index for the user. -k [ | all] — Index to assign the PK key being uploaded. all only works with the -v or -d options. must be between 1 to 4 or all on iDRAC. -t — Key text for the SSH Public key. -f — File containing the key text to upload. NOTE: The -f option is not supported on Telnet or SSH or serial RACADM.
Synopsis racadm sslcertdownload -f -t Input • • -f — Specifies the target filename on local file system to download the certificate. -t — Specifies the type of certificate to download, either the CA certificate for Directory Service or the server certificate. • • • • • 1=Server Certificate 2=Active Directory 3=Custom Signing Certificate 4=Client Trust Certificate for SSL 5=Factory Identity Certificate Output Returns 0 when successful and non-zero number when unsuccessful.
• Uploading Active Directory Certificate racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 2 -f ad_cert.txt • Uploading Client Trust certificate for SSL racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 4 -f https_cert.cer • Uploading Factory Identity Certificate racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 5 -f fi_cert.cer sslcertview Table 88. Details of sslcertview Description Displays the SSL server or CA certificate that exists on iDRAC.
Issuer Information: Country Code (CC) US State (S) Texas Locality (L) Round Rock Organization (O) Dell Inc.
racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate May 15 23:54:19 2017 GMT May 12 23:54:19 2027 GMT sslcertdelete Table 90. Details of sslcertdelete Description Command to delete a custom signing certificate from iDRAC. To run this subcommand, you must have the Configure iDRAC privilege.
sslcsrgen Table 91. Details of sslcsrgen Description Generates and downloads a certificate signing request (CSR) file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRAC. To run this subcommand, you must have the Configure iDRAC privilege.
• Generate and download a CSR for Factory Identity type to local file system using local RACADM racadm sslcsrgen -g -f c:\csr\csrtest.txt -t 2 NOTE: Before a CSR can be generated, the CSR fields must be configured in the RACADM iDRAC.Security group. For example: racadm set iDRAC.security.commonname MyCompany NOTE: In Telnet or SSH console, you can only generate and not download the CSR file. sslkeyupload Table 92. Details of sslkeyupload Description Uploads SSL key from the client to iDRAC.
NOTE: You can also run the command using raid in place of the storage command.
• To get the properties of the PCIeSSD enclosure, run the following command: racadm storage get enclosures: • To generate and view information about the inventory of physical disk drives, run the following command: racadm storage get pdisks racadm storage get pdisks -o racadm storage get pdisks -o -p racadm storage get pdisks --refkey racadm storage get pdisks --refkey
• To generate and view information about the inventory of EMMs, run the following command: racadm storage get emms -refkey racadm storage get emms --refkey -o racadm storage get emms --refkey -o -p • To generate and view information about the inventory of PSU, run the following command: racadm storage get psus -refkey racad
NOTE: T10PI is no longer supported on PERC9 and PERC10 controllers.
• To reset, clear, and import the storage configuration to the controller, run the following command: racadm storage importconfig: racadm storage resetconfig: racadm storage clearconfig: • To unlock foreign configuration: racadm storage unlock: -key -passwd • To start or stop a blink or identify operation on the specified or PCIeSSD device, run the following command: racadm storage blink: racadm storage blin
• • r60—storage 60-Spanned Striping with Extra Parity -new_rl—Specifies the new possible raid level for the virtual disk • • • • • • • • • r0—RAID0 r1—RAID1 r5—RAID5 r6—RAID6 NOTE: This is a mandatory option must provide with RLM operation. Possible raid migrations with disk addition are R0-R1, R0-R5/R6,R1-R0/R5/R6, R5-R0/R6, R6-R0/R5. Possible raid migrations without disk addition are R1-R0, R5-R0, R6-R0/R5.
• preparetoremove—Specifies the PCIeSSD drive to prepare for removal. NOTE: Ensure that ISM is installed and running to perform the preparetoremove operation. • • cryptographicerase—Specifies the PCIeSSD drive to perform the cryptographic erase operation.-mdtype { windows | linux}—Specifies the metadata type for the physical disk conversion to RAID NOTE: SWRAID only supports mdtype.
• To rename, expansion and raid level migration of the virtual disks. To rebuild, cancel rebuild and cancel the back-ground initialization.
PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport EnhancedAutoImportForeignConfig SupportControllerBootMode ControllerBootMode RealtimeConfigurationCapability RaidMode SharedSlotAssignmentAllowed bootVD CurrentControllerMode SupportEnhancedHBA = = = = = = = = = = = = = = = = = = 0x0 Other Other Other 12.
• This operation displays state of a pdisk on which createvd operation is pending: /admin1-> racadm storage get pdisks -o -p state -pending Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1 The following command displays the output for FD33xS storage sled controller objects along with their keys racadm storage get controllers -o RAID.Slot.
CheckConsistencyRate ReconstructRate PatrolReadRate PatrolReadMode PatrolReadState CheckConsistencyMode LoadBalanceSetting CopybackMode PreservedCache CacheMemorySize PersistHotspare KeyID SpindownUnconfiguredDrives SpindownHotspare Timeintervalforspindown SecurityStatus EncryptionMode SasAddress PciDeviceId PciSubdeviceId PciVendorId PciSubvendorId PciBus PciDevice PciFunction BusWidth SlotLength SlotType MaxCapableSpeed LearnMode T10PICapability SupportRAID10UnevenSpans SupportEnhancedAutoForeignImport En
The following command is an optimized and filtered version: racadm storage get batteries --refkey RAID.Integrated.1-1 -o -p Name Battery.Integrated.1:RAID.Integrated.1-1 Name = Battery • To generate and view information about the inventory of virtual disks that are connected to the controller, run the following command: racadm storage get vdisks Disk.Virtual.0:RAID.Integrated.
This command displays all enclosure objects for the connector FQDD. racadm storage get enclosures -o Enclosure.Internal.0-1:RAID.Integrated.1-1 Table 96. Details of storage get enclosure Status Ok State Ready DeviceDescription Backplane 1 on Connector 0 of Integrated RAID Controller 1 RollupStatus Ok Name BP13G+EXP 0:1 BayId 1 FirmwareVersion 0.
ForeignKeyIdentifier SasAddress FormFactor RaidNominalMediumRotationRate T10PICapability BlockSizeInBytes MaxCapableSpeed RaidType SystemEraseCapability SelfEncryptingDriveCapability EncryptionCapability CryptographicEraseCapability = = = = = = = = = = = = null 0x5000C500B8ED7081 2.
The following command is an optimized and filtered version: racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o -p State Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 State = Online • To generate and view information about the inventory of fans that are connected to the enclosure.
Name = PCIe SSD BP 1 SlotCount = 4 FirmwareVersion = 0.80 PcieSSDBusId = 182 PcieSSDDeviceId = 0 PcieSSDFunctionId = 0 • To get the list of physical disks and properties of the specified PCIeSSD physical disk. The following command provides the list of physical disks: racadm storage get pdisks Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.
Usage: racadm storage createvd: -rl {r0|r1|r5|r6|r10|r50|r60}[-wp {wt|wb|wbf}] [rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -pdkey: [-dcp {enabled|disabled|default}] [-name ] [-size {b|k|m|g|t}] [-T10PIEnable] -------------------------------------------------------------------------------Options : -rl : Set the RAID Level r0 : RAID 0 - Striping r1 : RAID 1 - Mirroring r5 : RAID 5 - Striping with Parity r6 : RAID
NOTE: Virtual disk must be created with SED. • The following command assigns security key for controller: racadm storage createsecuritykey:RAID.Integrated.1-1 -key -xxx • The following command modifies security key for controller: racadm storage modifysecuritykey:RAID.Integrated.1-1 -key -oldpasswd -newpasswd • The following command deletes security key for controller: racadm storage deletesecuritykey:RAID.Integrated.
• To prepare the specified PCIeSSD device for removal, run the following command: racadm storage preparetoremove: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 STOR089 : Successfully accepted the storage configuration operation. To apply the configuration operation, create a configuration job with --realtime option. To create the required commit jobs, run the jobqueue command.
• To collect the data and export to local share. This is only allowed from remote and local RACADM. racadm supportassist collect –t • To collect the data and export to remote share and to Dell SupportAssist server. racadm supportassist collect –t u -p --upload • -f -l - To Export the last collected SupportAssist data to a remote share.
• To clear the auto collection data racadm supportassist autocollectscheduler clear Input • -t—Specifies the types of logs to be included in the export data. • • • • • -sysinfo—System information • -osAppAll—OS and Application data • -ttylog—Storage log information • -Debug—iDRAC debug logs -l—Specifies the network share location. -u—Specifies the user name of the remote share. -p—Specifies the password of the remote share. -f—Specifies the target filename of the exported data.
• To collect the data and export to a TFTP share. racadm supportassist collect -t Debug -l tftp://192.168.10.24/share • To collect the data and export to an CIFS share. racadm supportassist collect -t sysinfo -l //192.168.10.24/share -u myuser -p mypasss • To collect the data and export to a HTTP share. racadm supportassist collect -t TTYLog -l http://192.168.10.24/share -u myuser -p mypass • To collect the data and export to an HTTPS share. racadm supportassist collect -t Debug -l https://192.168.
• To schedule auto collection of SupportAssist data weekly. racadm supportassist autocollectscheduler create -time 4:05am -dow sunday -rp weekly • To schedule auto collection of the SupportAssist data monthly. racadm supportassist autocollectscheduler create -time 7:55pm -dom 20 -rp monthly • To schedule auto collection of the SupportAssist data quarterly. racadm supportassist autocollectscheduler create -time 7:55am -wom 2 -dow monday -rp quarterly • To view the auto collection schedule.
------------------------------------------------------------------ComponentType = FIRMWARE ElementName = Broadcom Gigabit Ethernet BCM5720 - 00:0A:F7:E8:4A:C7 FQDD = NIC.Integrated.1-4-1 InstallationDate = NA Available Version = 20.8.4 HashValue = e8abf74757e0d0e01ff5f483af68b3ae62c6908ea0f7443f685b01c7baa9a81b ------------------------------------------------------------------ComponentType = FIRMWARE ElementName = Broadcom Gigabit Ethernet BCM5720 - 00:0A:F7:E8:4A:C7 FQDD = NIC.Integrated.
• To provide switch port details of requested FQDD NIC.Integrated.1-1-1:BRCM racadm switchconnection view NIC.Integrated.1-1-1:BRCM • To refresh switch port details of all ports in the server racadm switchconnection refresh systemconfig Table 100. Details of systemconfig Description Enables you to perform the following: • • • • Backup and restore for iDRAC and entire system configuration. Automatic scheduling of backup operation. View the auto backup feature settings.
• • -l—Specifies the network share location, can be either CIFS, NFS, HTTP, or HTTPS. -f—Specifies the image location and the file name. NOTE: If the file is in a subfolder within the share location, then specify the network share location in the –l option and specify the subfolder location and the filename in the –f option. • • • • • • -u—Specifies the user name for the remote share access. -p—Specifies the password for the remote share access. --vFlash—Selects vFlash SD as target location for back-up.
• Restore system from NFS share without clearing the VD configurations. racadm systemconfig restore -f image.img -l 192.168.0:/share -u admin -p xxx • Restore system from HTTP share without clearing the VD configurations. racadm systemconfig restore -f image.img -l http://test.com/share -u httpuser -p httppswd • Restore system from HTTPS share without clearing the VD configurations. racadm systemconfig restore -f image.img -l https://test.
• • • • • • • • • • diag—To erase embedded diagnostics. drvpack—To erase embedded OS driver pack. idrac—To reset the iDRAC to default. lcdata—To erase Lifecycle Controller data. allaps—To reset all apps. secureerasepd—To erase the physical disk. This supports SED, NVMe drives, and PCIe cards overwritepd—To overwrite physical disk. This supports SAS and SATA drives. percnvcache—To erase NV cache. vflash—To erase vFlash. nvdimm—To erase all NonVolatileMemory.
• racadm systemerase secureerasepd,vflash,percnvcache • racadm systemerase nvdimm systemperfstatistics Table 102. Details of systemperfstatistics Description Allows you to view and manage the system performance monitoring operations.
techsupreport Table 103. Details of techsupreport subcommand Description Allows you to perform the technical support report operations. Tech Support Report (TSR) is now known as SupportAssist Collections and the new term is used in all documentation and GUI. To maintain compatibility across server generations, the RACADM command has been retained as techsupreport. The types of operations are: • • • • Synopsis • collect—Collects the technical support report data to export.
• -f—target filename for the exported log. NOTE: The filename must have .zip as the extension. Examples • To collect the system information data. racadm techsupreport collect —t • To collect the system information and TTYLog data. racadm techsupreport collect -t SysInfo,TTYLog • To collect the operating system application data. racadm techsupreport collect -t OSAppAll • To export the collected Tech Support Report, to an FTP share racadm techsupreport export -l ftp://192.168.
• Make sure that the SMTP IP address is configured properly. racadm set idrac.remotehosts.SMTPServerIPAddress 192.168.0 • View the current email alert settings. racadm get idrac.EmailAlert. where is a number from 1 to 8. testtrap Table 105. Details of testtrap Description Tests the RAC’s SNMP trap alerting feature by sending a test trap from iDRAC to a specified destination trap listener on the network. To run this subcommand, you must have the Test Alert permission.
Output Success: Test trap sent successfully Failure: Unable to send test trap Example • Test a trap with index as 1. racadm testalert -i 1 Test trap sent successfully. • Test a trap that has not been configured yet. racadm testalert -i 2 ERROR: Trap at specified index is not currently enabled. traceroute Table 107. Details of traceroute Description Traces network path of the routers as the packets traverse from the system to a destination IPv4 address.
update Table 109. Details of update subcommand Description Allows you to update the firmware of devices on the server. The supported firmware image file types are: • • • • .exe — Windows-based Dell Update Package (DUP) .d9 .pm .sc The supported catalog files are: • • .xml xml.gzip NOTE: Updating the platforms from the repository is not supported for IPv6. NOTE: The firmware update through FTP has a limitation of file name up to 64 characters.
• —reboot—Performs a graceful system reboot after the firmware update. For Repository update: • -f: —Update filename . For update from repository .xml files are allowed. If a file name is not specified for repository update, Catalog.xml is taken as default. • • • • If a file name is not specified for repository update, then the Catalog.xml is taken as default. -u: < username for CIFS share>—Username of the remote share that stores the update file.
For devices that perform update process without rebooting the host, the update status changes from Downloading to Completed. For devices that require host reboot to perform update process, the update status changes from Downloading to Scheduled. When the status is displayed as Scheduled, reboot the host to start the update process.
• Upload the Update file from the local file system using local racadm and to perform a graceful system reboot after update: racadm update -f --reboot For Repository updates: • Perform update from an FTP repository and to apply the updates, reboot the server: racadm update -f Catalog.xml -l //192.168.11.10/Repo -u test -p passwd -a TRUE -t CIFS • Generate a comparison report using about the available updates in the repository: racadm update -f Catalog.xml -l 192.168.11.
Output If upload is successful, the message User certificate successfully uploaded to the RAC. If unsuccessful, appropriate error message is displayed. Example To upload user certificate for user 6. racadm usercertupload -t 1 -f c:\cert\cert.txt -i 6 usercertview Table 111. Details of usercertview Description Displays the user certificate or user CA certificate that exists on iDRAC.
Input • • Output If initialization is in progress, the message Initialization of the vFlash SD Card is now in progress is displayed. If unsuccessful, appropriate error message is displayed. Initialize— performs initialize operation on SD card. Status — indicates to view the progress or status report of the initialize operation. If the status of the last operation performed is successful, the message LastAction Progress Status=============Initialize SD Card 100 % Complete is displayed.
• Create a partition from a remote image. racadm vflashpartition create -i 1 -o Drive1 -e cddvd -t image -l //ipaddress/sharefolder/isoimge.iso -u username -p xxx A new partition is created. By default, the created partition is read-only. This command is case-sensitive for the image filename extension. If the filename extension is in uppercase, for example FOO.ISO instead of FOO.iso, then the command returns a syntax error. NOTE: • This feature is not supported in Local RACADM.
3 iDRAC Property Database Group and Object Descriptions The iDRAC property database contains the configuration information for iDRAC. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers and iDRAC Enterprise or Express on Rack and Tower Servers. To configure iDRAC, use the group and object IDs with the RACADM subcommands.
• • • • • cfgSensorRedundancy cfgVFlashSD cfgVFlashPartition cfgLogging cfgRacSecurity Displayable Characters Displayable characters include the following set: abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/ Table 115.
idRacVersionInfo (Read Only) Table 118. Details of idRacVersionInfo Description String containing the current product firmware version Legal Values A string of up to 63 ASCII characters. Default The current version number. idRacBuildInfo (Read Only) Table 119. Details of idRacBuildInfo Description String containing the current RAC firmware build version. Legal Values A string of up to 16 ASCII characters. Default The current iDRAC firmware build version. idRacName (Read Only) Table 120.
cfgNicStaticIPv4Enable (Read or Write) Table 122. cfgNicStaticIPv4Enable Description Enables or disables the IPv4 stack. Legal Values • • Default 1 — Enabled 0 — Disabled 1 — Enabled NOTE: If this object is modified, then the object cfgNicIPv4Enable is also modified. cfgNicStaticIpAddress (Read or Write) Table 123. cfgNicStaticIpAddress Description Returns or sets the current IPv4 address. NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0(false).
cfgNicStaticGateway (Read or Write) Table 126. cfgNicStaticGateway Description Returns or sets the static IPv4 address. Legal Values Any Valid IPv4 address Default 192.168.0.120 cfgDNSStaticServersFromDHCP (Read or Write) Table 127. cfgDNSStaticServersFromDHCP Description Specifies the DNS server static IP addresses. Legal Values • • Default 0 DNS Addresses are configured on the Device DNS Addresses are assigned via DHCP cfgDNSStaticServer1 (Read or Write) Table 128.
NOTE: Microsoft Active Directory only supports Fully Qualified Domain Names (FQDN) of 64 characters or fewer lengths. Default Null cfgDNSStaticDomainNameFromDHCP (Read or Write) Table 131. cfgDNSStaticDomainNameFromDHCP Description Specifies the device DNS static domain name. Legal Values • • Default 0 — Disabled 0 — Do not use DHCP to get the Domain Name 1 — Use DHCP to get the Domain Name cfgRemoteHosts This group provides properties that allow configuration of the SMTP server for email alerts.
Legal Values A string with a maximum length of 255 ASCII characters. Default cfgRhostsSmtpServerIpAddr (Read or Write) Table 135. Details of cfgRhostsSmtpServerIpAddr Description The IPv4 or IPv6 address of the network SMTP server. The SMTP server transmits email alerts from iDRAC if the alerts are configured and enabled. Legal Values A string representing a valid SMTP server IPv4 or IPv6 address. For example: 192.168.0.2. Default For IPv4, it is 0.0.0.
Legal Values String from 0 to 63 characters. Default cfgRhostsSyslogServer3 (Read or Write) Table 140. Details of cfgRhostsSyslogServer3 Description To store the RAC and SEL logs specify the third of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1(enabled). Legal Values String from 0 to 63 characters.
Legal Values • • • • 2 (User) 3 (Operator) 4 (Administrator) 15 (No access) Default • • 4 (User 2) 15 (All others) cfgUserAdminPrivilege (Read or Write) Table 144. Details of cfgUserAdminPrivilege Description This property specifies the role-based authority privileges allowed for the user. The value is represented as a bit mask that allows for any combination of privilege values. The table below describes the user privilege bit values that can be combined to create bit masks.
The user is not allowed to access iDRAC 0x00000000 The user may only log in to iDRAC and view iDRAC and server configuration information. 0x00000001 The user may log in to iDRAC and change configuration. 0x00000001 + 0x00000002 = 0x00000003 The user may log in to iDRAC, access Virtual Media, and Virtual Console. 0x00000001 + 0x00000040 + 0x00000080 = 0x000000C1 cfgUserAdminUserName (Read or Write) Table 147. Details of cfgUserAdminUserName Description The name of the user for this index.
• Default 0(FALSE) 1 (User 2), 0 (All others) cfgUserAdminSolEnable (Read or Write) Table 150. Details of cfgUserAdminSolEnable Description Enables or disables Serial Over LAN (SOL) user access for the user. Legal Values • • Default 0 1 (TRUE) 0(FALSE) cfgEmailAlert This group contains parameters to configure iDRAC email alerting capabilities. Up to four instances of this group are allowed. Use this object with the config or getconfig subcommands.
cfgEmailAlertCustomMsg (Read or Write) Table 154. Details of cfgEmailAlertCustomMsg Description Specifies a custom message that forms the subject of the alert. Legal Values A string of up to 32 characters Default cfgEmailAlertEmailName (Read Only) Table 155. Details of cfgEmailAlertEmailName Description Specifies name or other identifier associated with the destination email address. The email name can refer to an individual, group, location, department, and so on.
cfgSsnMgtConsRedirMaxSessions (Read or Write) Table 157. Details of cfgSsnMgtWebserverTimeout Description Specifies the maximum number of Virtual Console sessions allowed on iDRAC. Legal Values 1–4 Default 4 cfgSsnMgtWebserverTimeout (Read or Write) Table 158. Details of cfgSsnMgtWebserverTimeout Description Defines the web server time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input).
• For iDRAC Enterprise on Blade Servers: Session timed out. Closing the session. After the message is displayed, the system returns you to the shell that generated the Telnet session. Legal Values • • 0 (No timeout) 60–10800 NOTE: If 0 (no timeout is specified), the network connection does not send alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding.
For example, striking both the CTRL key and the \ key simultaneously (rather than sequentially) is denoted as ^\. Configuration options: The value must start with the ^ character, and must follow one of the characters — a-z, AZ, [,], \ In the input command, use \ without the quotes. For example: config -g cfgSerial -o cfgSerialConsoleQuitKey "SHIFT+6"\\ Default: \ cfgSerialConsoleIdleTimeout (Read or Write) Table 164.
cfgSerialCom2RedirEnable (Read or Write) Table 168. Details of cfgSerialSshEnable Description Enables or disables the console for COM 2-port redirection. The cfgSerialCom2RedirEnable object property is applicable only for iDRAC on Rack and Tower Servers. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgSerialSshEnable (Read or Write) Table 169. Details of cfgSerialSshEnable Description Enables or disables the secure shell (SSH) interface.
cfgOobSnmpAgentCommunity (Read or Write) Table 171. Details of cfgOobSnmpAgentCommunity Description Specifies the SNMP Community Name used for SNMP traps. The community string acts as a password shared between different hosts over the network. This community string value must match with the other hosts for any kind of communication through SNMP. Legal Values A string of up to 31 characters.
Default 1 cfgRacTuneCtrlEConfigDisable Table 175. Details of cfgRacTuneCtrlEConfigDisable Description To configure iDRAC from the BIOS POST option-ROM, enables or disables the ability of the local user. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuneHttpPort (Read or Write) Table 176.
Default 192.168.0 cfgRacTuneIpRangeMask (Read or Write) Table 180. Details of cfgRacTuneIpRangeMask Description Standard IP mask values with left-justified bits. For example, 255.255.255.0. Legal Values An IPv4 address formatted string, for example, 255.255.255.0. Default 255.255.255.0 cfgRacTuneSshPort (Read or Write) Table 181. Details of cfgRacTuneSshPort Description Specifies the port number used for the SSH interface.
cfgRacTuneAsrEnable (Read or Write) Table 185. Details of cfgRacTuneAsrEnable Description Enables or disables iDRAC last crash screen capture feature. This object property requires an iDRAC reset before it becomes active. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuneDaylightOffset (Read Only) Table 186. Details of cfgRacTuneDaylightOffset Description Specifies the daylight savings offset (in minutes) to use for the RAC Time.
Example racadm getconfig -g cfgRacTuning cfgRacTuneRemoteRacadmEnable=1 cfgRacTuneWebserverEnable=1 cfgRacTuneHttpPort=80 cfgRacTuneHttpsPort=443 cfgRacTuneTelnetPort=23 cfgRacTuneSshPort=22 cfgRacTuneIpRangeEnable=0 cfgRacTuneIpRangeAddr=192.168.1.1 cfgRacTuneIpRangeMask=255.255.255.0 # cfgRacTuneTimezoneOffset=-18000 # cfgRacTuneDaylightOffset=3600 cfgRacTuneLocalServerVideo (Read or Write) Table 188. Details of cfgRacTuneLocalServerVideo Description Enables or disables the local server video.
cfgRacTuneVirtualConsoleAuthorizeMultipleSessions (Read or Write) Table 191. Details of cfgRacTuneVirtualConsoleAuthorizeMultipleSessions Description If a first user is already using the Virtual Console, the value of this object affects the privileges granted to the subsequent user’s shared request after the timeout of 30 seconds. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
Legal Values A string of up to 255 characters. Default cfgRacVirtual This group contains parameters to configure the iDRAC Virtual Media feature. One instance of the group is allowed. The following sections provide information about the objects in the cfgRacVirtual. cfgVirMediaAttached (Read or Write) Table 195. Details of cfgVirMediaAttached Description This object is used to attach virtual devices to the system via the USB bus.
Default 0 cfgSDWriteProtect (Read Only) Table 198. Details of cfgSDWriteProtect Description Displays if the physical write protect latch on the SD card is enabled or disabled. NOTE: This command is deprecated from 12G iDRAC 1.0 release onwards. The functionality of this command is covered by cfgVFlashSDWriteProtect. While execution of the cfgSDWriteProtect command is successful, use the cfgVFlashSDWriteProtect command. For more information, see cfgVFlashwriteProtect (Read Only).
cfgServerDNSIMCName (Read or Write) Table 202. Details of cfgServerDNSIMCName Description Displays the DNS domain name for iDRAC or IMC. Legal Values A valid string values Default None cfgServerFirstBootDevice (Read or Write) Table 203. Details of cfgServerFirstBootDevice Description Sets or displays the first boot device. You can also set a vFlash partition that is attached as a bootable device. For more information, see cfgVFlashPartitionOSVoLabel.
Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgActiveDirectory. cfgADSSOEnable (Read or Write) Table 205. Details of cfgADSSOEnable Description Enables or disables Active Directory single sign-on authentication on iDRAC. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgADDomainController1 (Read or Write) Table 206.
Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADRacDomain (Read or Write) Table 210. Details of cfgADRacDomain Description Active Directory Domain in which iDRAC resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADAuthTimeout (Read or Write) Table 211.
This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADGlobalCatalog2 (Read or Write) Table 215. Details of cfgADGlobalCatalog2 Description To obtain user names, specify the Global Catalog server from which you want the iDRAC. This object is applicable only to iDRAC.
cfgADDcSRVLookupbyUserdomain (Read or Write) Table 219. Details of cfgADDcSRVLookupbyUserdomain Description Chooses the way the user domain is looked up for Active Directory. This object is applicable only to iDRAC. Legal Values • • Default 1 (TRUE) — use user domain as the search domain to look up DCs. The user domain is chosen from either the user domain list or by entering into the user login. 0 (FALSE) — use the configured search domain cfgADDcSrvLookupDomainName to look up DCs.
cfgLDAPBaseDN (Read or Write) Table 223. Details of cfgLDAPBaseDN Description The domain name of the branch of the directory where all searches must start. Legal Values String. Maximum length = 254 Default Null cfgLDAPBindPassword (Write Only) Table 224. Details of cfgLDAPBindPassword Description A bind password is used with the bindDN. The bind password is a sensitive data, and must be protected. It is optional to support anonymous bind.
Default 0 cfgLDAPGroupAttribute (Read or Write) Table 228. Details of cfgLDAPGroupAttribute Description Specifies which LDAP attribute is used to check for group membership. It must be an attribute of the group class. If not specified then the member and unique member attributes are used. Legal Values String maximum length = 254 Default Null cfgLDAPGroupAttributeIsDN (Read or Write) Table 229.
NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. Maximum length = 1024 Default Null cfgLDAPUserAttribute (Read or Write) Table 233. Details of cfgLDAPUserAttribute Description To search for, specify the user attribute. It is recommended to be unique within the chosen baseDN, otherwise a search filter must be configured to make sure the uniqueness of the login user.
Default 0x000 Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupPrivilege -i 1 0x0 cfgStandardSchema This group contains parameters to configure the Active Directory standard schema settings. Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgStandardSchema. cfgSSADRoleGroupDomain (Read or Write) Table 236. Details of cfgSSADRoleGroupDomain Description Active Directory Domain in which the Role Group resides.
• Example racadm getconfig -g cfgStandardSchema -i 1 # cfgSSADRoleGroupIndex=1 cfgSSADRoleGroupName=blsys-1 cfgSSADRoleGroupDomain= cfgSSADRolGroupPrivilege=3081 Table 240.
Legal Values • • Default 1 1(TRUE) 0(FALSE) cfgIpmiSolBaudRate (Read or Write) Table 243. Details of cfgIpmiSolBaudRate Description Specifies baud rate for serial communication over LAN. Legal Values 9600, 19200, 57600, 115200 Default 115200 cfgIpmiSolMinPrivilege (Read or Write) Table 244. Details of cfgIpmiSolMinPrivilege Description Specifies the minimum privilege level required for SOL access.
cfgIpmiLanEnable (Read or Write) Table 247. Details of cfgIpmiLanEnable Description Enables or disables the IPMI over LAN interface. Legal Values • • Default 0 1(TRUE) 0(FALSE) cfgIpmiLanPrivLimit (Read or Write) Table 248. Details of cfgIpmiLanPrivLimit Description Specifies the maximum privilege level allowed for IPMI over LAN access. Legal Values • • • \Default 4 2(User) 3(Operator) 4(Administrator) cfgIpmiLanAlertEnable (Read or Write) Table 249.
cfgIpmiPetIpv6 This group is used to configure IPv6 platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPetIpv6 group. cfgIpmiPetIPv6Index (Read Only) Table 252. Details of cfgIpmiPetIPv6Index Description Unique identifier for the index corresponding to the trap. Legal Values 1–4 Default cfgIpmiPetIPv6AlertDestIpAddr Table 253.
cfgIpmiPefIndex (Read or Write) Table 256. Details of cfgIpmiPefIndex Description Specifies the index of a specific platform event filter. Legal Values • • Default The index value of a platform event filter object. For iDRAC on Rack and Tower Servers: 1–22 For iDRAC Enterprise on Blade Servers: 1–9 cfgIpmiPefAction (Read or Write) Table 257. Details of cfgIpmiPefAction Description Specifies the action that is performed on the managed server when the alert is triggered.
cfgIpmiPetAlertDestIpAddr (Read/Write) Table 260. Details of cfgIpmiPetAlertDestIpAddr Description Specifies the destination IPv4 address for the trap receiver on the network. The trap receiver receives an SNMP trap when an event is triggered on the managed server. Legal Values A string representing a valid IPv4 address. For example, 192.168.0.67. Default 0.0.0.0 cfgIpmiPetAlertEnable (Read or Write) Table 261. Details of cfgIpmiPetAlertEnable Description Enables or disables a specific trap.
cfgServerPowerStatus (Read Only) Table 264. Details of cfgServerPowerStatus Description Represents the server power state, either ON or OFF. Legal Values • • Default 0 1 (ON) 0 (OFF) cfgServerPowerAllocation (Read Only) Table 265. Details of cfgServerPowerAllocation Description Represents the available allocated power supply for server usage. NOTE: If there is more than one power supply, this object represents the minimum capacity power supply.
Legal Values Not applicable Default cfgServerMaxPowerCapacity (Read Only) Table 269. Details of cfgServerMaxPowerCapacity Description Represents the maximum server power capacity based on the current component consumption. Legal Values Not applicable Default cfgServerPeakPowerConsumption (Read Only) Table 270. Details of cfgServerPeakPowerConsumption Description Represents the server's maximum power consumption until the current time.
Default Server power threshold in Watts. cfgServerPowerCapBtuhr (Read or Write) Table 274. Details of cfgServerPowerCapBtuhr Description Represents the server power threshold in BTU/hr. NOTE: This value is applicable only if cfgServerPowerCapEnable is set to 1. Legal Values None Default Server power threshold in BTU/hr. cfgServerPowerCapPercent (Read or Write) Table 275. Details of cfgServerPowerCapPercent Description Represents the server power threshold in percentage.
Default Average power value during the last week. cfgServerPowerLastHourMinPower (Read Only) Table 279. Details of cfgServerPowerLastHourMinPower Description Displays the minimum power value during the last hour. Legal Values Not applicable Default Minimum power value during the last hour. cfgServerPowerLastHourMinTime (Read Only) Table 280. Details of cfgServerPowerLastHourMinTime Description Displays the timestamp of minimum power value during the last minute.
• • • • Default YYYY = Year HH = hour MM=Minutes SS = Seconds Maximum power value during the last hour. cfgServerPowerLastDayMinPower (Read Only) Table 283. Details of cfgServerPowerLastDayMinPower Description Displays the minimum power value during the last day. Legal Values Not applicable Default Minimum power value during the last day. cfgServerPowerLastDayMinTime (Read Only) Table 284.
• • • • • • • Default DD = Day of the week MM = Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the maximum power value during the last day. cfgServerPowerLastWeekMinPower (Read Only) Table 287. Details of cfgServerPowerLastWeekMinPower Description Displays the minimum power value during the last week. Legal Values Not applicable Default Minimum power value during the last week. cfgServerPowerLastWeekMinTime (Read Only) Table 288.
cfgServerPowerLastWeekMaxTime (Read Only) Table 290. Details of cfgServerPowerLastWeekMaxTime Description Displays the timestamp of maximum power value during the last week. Legal Values A string of up to 32 characters. Time in the format: DD MM Date HH:MM:SS YYYY where, • • • • • • • Default DD = Day of the week MM= Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the maximum power value during the last week. cfgServerPowerInstHeadroom (Read Only) Table 291.
cfgServerPeakAmperage (Read Only) Table 294. Details of cfgServerPeakAmperage Description Displays the current peak power consumption. Legal Values Not applicable Default Current peak power consumption. cfgServerPeakAmperageTimeStamp (Read Only) Table 295. Details of cfgServerPeakAmperageTimeStamp Description Displays the timestamp of the current peak power consumption. Legal Values A string of up to 32 characters.
• • • • Default YYYY = Year HH = hour MM=Minutes SS = Seconds Timestamp of the cumulative power consumption. cfgServerCumulativePowerClear (Write Only) Table 298. Details of cfgServerCumulativePowerClear Description Clears the cfgServerCumulativePowerConsumption and cfgServerCumulativePowerConsumptionTimeStamp values. Legal Values 1 Default None cfgServerPowerPCIeAllocation (Read or Write) Table 299. Details of cfgServerPowerPCIeAllocation Description Amount of power allocated to the PCIe cards.
cfgServerPowerSupplyFwVer (Read Only) Table 301. Details of cfgServerPowerSupplyFwVer Description Displays the firmware version of the PSU, in the format x.xx.xxx. Legal Values A string up to 8 characters. Default Null cfgServerPowerSupplyIndex Table 302. Details of cfgServerPowerSupplyIndex Description Specifies index of the PSU. NOTE: Indexes 1–8 are supported to support up to 8 PSUs.
cfgServerPowerSupplyType Table 306. Details of cfgServerPowerSupplyType Description Displays whether the power supply is AC or DC. Legal Values A string of up to 32 characters. Default 0 cfgIPv6LanNetworking This group is used to configure the IPv6 over LAN networking capabilities. Use this object with the config or getconfig subcommands. The following sections provide information about the objects in the cfgIPv6LanNetworking group. cfgIPv6Enable (Read or Write) Table 307.
NOTE: If this value is set to 0, the iDRAC disables auto configuration and statically assigns IPv6 addresses. If this value is set to 1, the iDRAC obtains address and route information using stateless auto configuration and DHCPv6. NOTE: The iDRAC uses its MAC address for its DUID (DUID-LL) when communicating with a DHCPv6 server. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgIPv6PrefixLength (Read or Write) Table 311.
cfgIPv6Address4 (Read Only) Table 315. Details of cfgIPv6Address4 Description The iDRAC IPv6 fourth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address5 (Read Only) Table 316. Details of cfgIPv6Address5 Description The iDRAC IPv6 fifth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address6 (Read Only) Table 317. Details of cfgIPv6Address6 Description The iDRAC IPv6 sixth address.
cfgIPv6Address9 (Read Only) Table 320. Details of cfgIPv6Address9 Description The iDRAC IPv6 ninth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address10 (Read Only) Table 321. Details of cfgIPv6Address10 Description The iDRAC IPv6 tenth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address11 (Read Only) Table 322. Details of cfgIPv6Address11 Description The iDRAC IPv6 eleventh address.
cfgIPv6Address14 (Read Only) Table 325. Details of cfgIPv6Address14 Description The iDRAC IPv6 fourteenth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6Address15 (Read Only) Table 326. Details of cfgIPv6Address15 Description The iDRAC IPv6 fifteenth address. Legal Values String representing a valid IPv6 entry. Default : cfgIPv6DNSServer1 (Read or Write) Table 327. Details of cfgIPv6DNSServer1 Description Specifies the IPv6 DNS server address.
cfgIPv6StaticEnable (Read or Write) Table 329. Details of cfgIPv6StaticEnable Description Enables or disables the static IPv6 stack. Legal Values • • Default 0 — Disabled 0 — Disabled 1 — Enabled NOTE: If this object is modified, then the object cfgIPv6Enable is also modified. cfgIPv6StaticAddress1 (Read or Write) Table 330. Details of cfgIPv6StaticAddress1 Description Returns or sets the static IPv6 address1. NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0 (false).
NOTE: If this object is modified, then the object cfgIPv6Autoconfig is also modified. cfgIPv6StaticDNSServersFromDHCP6 (Read or Write) Table 334. Details of cfgIPv6StaticDNSServersFromDHCP6 Description Specifies the DNS server static IP addresses. Legal Values • • Default 0 — Disabled 0 — DNS Server must be configured as static. 1 — The device will get the DNS servers from DHCPv6. cfgIPv6StaticDNSServer1 (Read or Write) Table 335.
Example $ racadm getconfig -g cfgIPv6LanNetworking cfgIPv6Enable=1 cfgIPv6AutoConfig=1 cfgIPv6Address=:: cfgIPv6PrefixLength=64 cfgIPv6Gateway=:: cfgIPv6DNSServersFromDHCP6=1 cfgIPv6DNSServer1=:: cfgIPv6DNSServer2=:: If both IPv4 and IPv6 are enabled on the iDRAC, IPv6 DNS servers take priority. The order of preference for DNS servers is: • • • • cfgIPv6DNSServer1 cfgIPv6DNSServer2 cfgDNSServer1 cfgDNSServer2 cfgIPv6URL This group specifies properties used to configure iDRAC IPv6 URL.
Default 57600 cfgIpmiSerialChanPrivLimit (Read or Write) Table 340. Details of cfgIpmiSerialChanPrivLimit Description Specifies the maximum privilege level allowed on the IPMI serial channel. Legal Values • • • Default 4 2 (User) 3 (Operator) 4 (Administrator) cfgIpmiSerialConnectionMode (Read or Write) Table 341. Details of cfgIpmiSerialConnectionMode Description When the iDRAC cfgSerialConsoleEnable property is set to 0(disabled), the iDRAC serial port becomes the IPMI serial port.
cfgIpmiSerialFlowControl (Read or Write) Table 344. Details of cfgIpmiSerialFlowControl Description Specifies the flow control setting for the IPMI serial port. Legal Values • • Default 1 0 (None) 1 (CTS or RTS) cfgIpmiSerialHandshakeControl (Read or Write) Table 345. Details of cfgIpmiSerialHandshakeControl Description Enables or disables the IPMI terminal mode handshake control. Legal Values • • Default 1 0(FALSE) 1 (TRUE) cfgIpmiSerialInputNewLineSequence (Read or Write) Table 346.
• • Default 4 — LF-CR 5 — LF 1 cfgSmartCard This group specifies properties used to support access to iDRAC using a smart card. The following sections provide information about the objects in the cfgSmartCard group. cfgSmartCardLogonEnable (Read or Write) Table 349. Details of cfgSmartCardLogonEnable Description To iDRAC using a smart card, enable or disable with Remote RACADM support for access. NOTE: Enabling with remote RACADM is only applicable for iDRAC on Rack and Tower Servers.
cfgNetTuningNicAutoneg (Read or Write) Table 351. Details of cfgNetTuningNicAutoneg Description Enables auto negotiation of physical link speed and duplex. If enabled, auto negotiation takes priority over other values set in this group.
cfgNetTuningNicMtu (Read or Write) Table 354. Details of cfgNetTuningNicMtu Description Indicated the maximum size of units in bytes transmitted by NIC. Legal Values 576–1500 Default 1500 cfgSensorRedundancy This group is used to set the power supply redundancy. The following sections provide information about the objects in the cfgSensorRedundancy group. This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
Default Any legal value at that particular execution instance. cfgSensorRedundancyStatus (Read Only) Table 358. Details of cfgSensorRedundancyStatus Description Indicates the redundancy status. The status is N/A on platforms that do not support the power supply sensor redundancy. Legal Values String: • • • • Default N/A Full Lost Degraded None cfgVFlashSD This group is used to configure the properties for the Virtual Flash SD card.
cfgVFlashSDSize (Read Only) Table 361. Details of cfgVFlashSDSize Description Displays the size of the vFlash SD card in megabytes (MB). Legal Values A string of up to 64 characters. Default cfgVFlashSDLicensed (Read Only) Table 362. Details of cfgVFlashSDLicensed Description Displays whether an SD card or vFlash SD card is inserted. The vFlash SD card supports the new enhanced vFlash features and the SD card supports only the limited vFlash features.
Default None cfgVFlashPartition This group is used to configure properties for individual partitions on the vFlash SD Card. Up to 16 partitions are supported, indexed from 1 to 16. NOTE: For SD cards, the index value is limited to 1 because only a single partition of size 256MB is allowed. The following sections provide information about the objects in the cfgVFlashPartition group. cfgVFlashPartitionIndex (Read Only) Table 366.
cfgVFlashPartitionFormatType (Read Only) Table 370. Details of cfgVFlashPartitionFormatType Description Displays the format type of the partition. Legal Values String: • • • • • • Default FAT16 FAT32 EXT2 EXT3 CD RAW None cfgVFlashPartitionAccessType (Read or Write) Table 371. Details of cfgVFlashPartitionAccessType Description Indicates the partition access permissions. It configures the access type to read-write.
Default 0 cfgRacSecurity For more information about generating certificate signing requests, see the subcommand sslcsrgen. For the country code, go to the link http://www.iso.org/iso/country_codes/iso_3166_code_lists.htm The following sections provide information about the objects in the cfgRacSecurity group. cfgRacSecCsrCommonName (Read or Write) Table 374. Details of cfgRacSecCsrCommonName Description Specifies the CSR Common Name (CN) that must be an IP or iDRAC name as given in the certificate.
cfgRacSecCsrStateName (Read or Write) Table 378. Details of cfgRacSecCsrStateName Description Specifies the CSR State Name (S). Legal Values A string of up to 128 characters. Default cfgRacSecCsrCountryCode (Read/Write) Table 379. Details of cfgRacSecCsrCountryCode Description Specifies the CSR Country Code (CC). Legal Values A string of 2 alphabet country code. Default US cfgRacSecCsrEmailAddr (Read or Write) Table 380.
4 Database Objects With Get and Set Commands This chapter provides the database groups and objects that must be used with the get or set subcommands. When using the objects, they must begin with FQDD or FQDD alias. The set operations for iDRAC, Lifecycle Controller, and system objects do not require server restart. However, the set operations for NIC and BIOS objects are staged to apply and commit the pending values.
Usage 4; 5Retries - 5;6RetriesRequired License Dependency -6; --- NoRetry - 0;1Retry - 1; 2Retries - 2;3Retries - 3;4Retries IndefiniteRetries, Default - NoRetry RACADM None BootStrapType system.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 228 System.AcquisitionInfo System.Backplane System.SC-BMC System.ChassisControl System.ChassisInfo System.DepreciationInfo System.ExWarrantyInfo System.LCD System.LeaseInfo System.MaintenanceInfo System.OutsourceInfo System.OwnerInfo System.ServerTopology System.ServiceContract System.PCIESlotLFM System.Power System.Power.Supply System.QuickSync System.ServerOS System.Serverpwr System.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iDRAC.Redfish iDRAC.Redfisheventing iDRAC.RemoteHosts iDRAC.RFS iDRAC.RSM iDRAC.Security iDRAC.Serial iDRAC.SerialRedirection iDRAC.serverboot iDRAC.ServiceModule iDRAC.SmartCard iDRAC.SNMP iDRAC.SupportAssist iDRAC.SNMPAlert iDRAC.SSH iDRAC.SwitchConnectionView (Read Only) iDRAC.SysLog iDRAC.Telnet iDRAC.Time iDRAC.DefaultCredentialMitigationConfigGroup iDRAC.Update iDRAC.USB iDRAC.
• • • • • • • • • • • • • • NIC.FrmwImgMenu NIC.GlobalBandwidthAllocation NIC.IscsiFirstTgtParams NIC.IscsiGenParams NIC.IscsiInitiatorParams NIC.IscsiSecondaryDeviceParams NIC.IscsiSecondTgtParams NIC.NICConfig NIC.NICPartitioningConfig NIC.VndrConfigGroup Storage.Controller Storage.enclosure Storage.PhysicalDisk Storage.VirtualDisk System.AcquisitionInfo This group contains the attributes that provides details about System.AcquisitionInfo. System.AcquisitionInfo.
System.AcquisitionInfo.PONumber (Read or Write) Description Number of the purchase order that authorized buying the system. Legal Values None Default Values • Write Privilege Configure iDRAC License Required Not Applicable Dependancy None 0 System.AcquisitionInfo.PurchaseCost (Read or Write) Description Value expressed in currency unit that was paid for the system, for example, 25000.
License Required Not Applicable Dependancy None System.AcquisitionInfo.WhoSigned (Read or Write) Description Person who accepted delivery of the system. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.Backplane The objects in this group manage the backplane. System.Backplane.BackplaneBusMode (Read Only) Table 381. Details of System.Backplane.
System.SC-BMC.ChassisPowerCap (Read) Table 383. Details of System.SC-BMC.ChassisPowerCap Description Indicates the Chassis Powercap Legal Values 0–2400 Watts Default value Not Applicable Write Privilege Not Applicable License Required Not Applicable Dependency None System.ChassisControl The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To control the chassis related events, use this group. System.ChassisControl.
System.ChassisInfo.ConnectionState(Read or Write) NOTE: The System.ChassisInfo.Model attribute is deprecated and replaced with System.ChassisInfo.ConnectionState attribute. Table 386. Details of System.ChassisInfo.ConnectionState Description Indicates the chassis connection state Legal Values • • • Default Value 0-Unknown Write privilege Configure iDRAC 0-Unknown 1-Disconnected/Offline 2-Connected/Ready License Required RACADM Dependency None System.ChassisInfo.
System.ChassisModel (Read Only) NOTE: The System.ChassisInfo.Model attribute is deprecated and replaced with ChassisModel attribute. Table 390. Details of ChassisModel Description Indicates the LCD string the user modifies. Legal Values String of up to 62 ASCII characters Default Value None Write privilege Not Applicable License Required Not Applicable Dependency None System.ChassisName (Read Only) NOTE: The System.ChassisInfo.Name attribute is deprecated and replaced with System.
Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.CustomAsset.Value (Read or Write) Description Custom Asset value Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.DepreciationInfo This group contains the attributes that provides details about System.DepreciationInfo. System.DepreciationInfo.
System.DepreciationInfo.Percentage (Read or Write) Description Indicates the portion of 100 that an asset is devalued or depreciated. If the duration of depreciation is 5 years, and the method is straight line, then the percentage is 20 percent. Legal Values None Default Values • Write Privilege Configure iDRAC License Required Not Applicable Dependancy None 0 System.ExWarrantyInfo This group contains the attributes that provides details about System.ExWarrantyInfo System.ExtWarrantyInfo.
Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.LCD This group enables you to manage the front panel LCD user string settings. The following section provides information about the objects in the System.LCD group. NOTE: The System.LCD get and set command works on iDRAC on Blade Server, even if the LCD is not present on the server.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.CurrentDisplay (Read Only) Table 395. Details of System.LCD.CurrentDisplay Description The string currently displayed on the LCD. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.LCDUserString (Read or Write) Table 396. Details of System.LCD.LCDUserString Description Indicates the LCD string set.
• BTU per hour Default Value Watts Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.LCD.UserDefinedString (Read or Write) Table 399. Details of System.LCD.UserDefinedString Description Indicates the LCD string set. Legal Values String of up to 62 ASCII characters Default Value 0 Write Privilege Not Applicable License Required Not Applicable Dependency Cannot be configured unless LCD Configuration is user defined. System.
Default Values • Write Privilege Configure iDRAC License Required Not Applicable Dependancy None 0 System.LeaseInfo.Lessor (Read or Write) Description Displays the name of the business entity that is leasing the system to the user. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.LeaseInfo.
License Required Not Applicable Dependancy None System.MaintenanceInfo.Provider (Read or Write) Description The business entity that provides maintenance on a system. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.MaintenanceInfo.Restrictions (Read or Write) Description Any exclusions that apply to the maintenance agreement for the system.
System.OutsourceInfo.ProviderFee (Read or Write) Description Defines any additional fee invoiced by the outsource service provider. Legal Values None Default Values • Write Privilege Configure iDRAC License Required Not Applicable Dependancy None 0 System.OutsourceInfo.ServiceFee (Read or Write) Description Amount of money paid for either the service contract or for corrective action on a specific problem component.
System.OwnerInfo.InsComp (Read or Write) Description The company that insures the system against theft or other loss. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.OwnerInfo.OwnerName (Read or Write) Description The individual or business entity that holds legal title to the system. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.
Dependency None System.LServerTopology.DataCenter (Read or Write) Table 401. Details of System.ServerTopology.DataCenter Description Indicates name of the data center where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerTopology.DeviceSize (Read Only) Table 402. Details of System.ServerTopology.
Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerTopology.RoomName (Read or Write) Table 405. Details of ServerTopology.Location.RoomName Description Room name where the system is located. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Location.ServerTopology.
System.ServiceContract.Renewed (Read or Write) Description Whether the service contract was renewed or not (Yes or No). Legal Values • • 0-Yes 1-No Default Values • 1 Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.ServiceContract.Type (Read or Write) Description Type refers to the name or feature of the system covered by the service contract. For example, Installation Service, Maintenance Service, Return Service, Gold Service, Premier Service.
Dependency None System. pcieSlotLFM. CardType (Read) Table 409. Details of System. pcieSlotLFM. CardType Description Indicates the type of PCIe card installed. Legal Values Not Applicable Default value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System. pcieSlotLFM. CustomLFM (Read or Write) Table 410. Details of System. pcieSlotLFM. CustomLFM Description Indicates the minimum airflow to be delivered the installed PCIe card.
Dependency None System.pcieSlotLFM.Slot (Read) Table 413. Details of System.pcieSlotLFM.Slot Description Indicates the PCIe slot number Legal Values Not Applicable Default value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None System. pcieSlotLFM.SlotState (Read) Table 414. Details of System. pcieSlotLFM.
System.Power This group provides power management features for iDRAC. The following section provides information about the objects in this group. NOTE: For Dell PowerEdge FM120x4 server with more than one iDRAC, the power is received and shared from CMC. Hence, the information about power and temperature for individual iDRACs are not displayed. System.Power.Status (Read Only) Table 416. Details of System.Power.Status Description Represents the device power state, either ON or OFF.
System.Power.Avg.LastHour (Read Only) Table 419. Details of System.Power.Avg.LastHour Description Displays the average power value during the last hour. Legal Values Values: 1–65535 Default Value Average power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Avg.LastWeek (Read Only) Table 420. Details of System.Power.Avg.LastWeek Description Indicates the average power value during the last week.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.ActivePolicy.Watts (Read Only) Table 423. Details of System.Power.Cap.ActivePolicy.Watts Description Displays the Active Power Capacity in Watts Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.Btuhr (Read or Write) Table 424. Details of System.Power.Cap.
System.Power.Cap.MaxThreshold (Read Only) Table 426. Details of System.Power.Cap.MaxThreshold Description Because it is based on the current component inventory, it has maximum server power capacity. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.MinThreshold (Read Only) Table 427. Details of System.Power.Cap.
• • • 0 — Not Redundant — In this mode, even if one PSU stops functioning, the server is automatically turned off. 1 — Input Power Redundant — In this mode, the system is functional even if one PSU input circuit stops functioning, provided the PSUs are connected to different input circuits. This is also called AC redundancy. 2 — PSU Redundant — Available only on systems with four PSUs. This is also called DC redundancy. This is only valid in a 2+1 PSU configuration.
Legal Values 1 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.StarttimeStamp (Read Only) Table 433. Details of System.Power.EnergyConsumption.StarttimeStamp Description Displays the Timestamp of the cumulative power consumption. Legal Values String of up to 254 ASCII characters Default Value Timestamp of the cumulative power consumption.
Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps (Read Only) Table 436. Details of System.Power.Max.Amps Description Specifies the device Peak Power Consumption since this value was last cleared. Legal Values Values: 1–65535. Default Value Current peak power consumption Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps.
System.Power.Max.LastDay (Read Only) Table 439. Details of System.Power.Max.LastDay Description Displays the maximum power value during the last day. Legal Values Values: 1–65535 Default Value Maximum power value during the last day. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastDay.TimeStamp (Read Only) Table 440. Details of System.Power.Max.LastDay.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek (Read Only) Table 443. Details of System.Power.Max.LastWeek Description Displays the maximum power value during the last week. Legal Values Values: 1–65535 Default Value Maximum power value during the last week. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek.TimeStamp (Read Only) Table 444. Details of System.Power.Max.LastWeek.
Legal Values String of up to 254 ASCII characters Default Value Timestamp of the peak power consumption of the server. Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.PowerClear (Read or Write) Table 447. Details of System.Power.Max.PowerClear Description Clears the Maximum Power Consumption timestamps.
System.Power.Min.LastHour (Read Only) Table 450. Details of System.Power.Min.LastHour Description Indicates the minimum power value during the last hour. Legal Values Values: 1–65535 Default Value Minimum power value during the last hour. Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Min.LastHour.Timestamp (Read Only) Table 451. Details of System.Power.Min.LastHour.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.PCIeAllocation (Read or Write) Table 454. Details of System.Power.PCIeAllocation Description Specifies PCIe power allocation for blade servers. It is applicable only for PowerEdge M610x. NOTE: This object only applies to servers that support PCIe Card. Legal Values • • 0 — Disabled 1 — Enabled Default Value • • 0 — For platforms that do not support PCIe cards. 500 W — For platforms that support PCIe cards.
• • • • • • 2 — 1+1 Redundant 4 — 2+1 Redundant 8 — 2+2 Redundant 16 — 3+x Redundant 32 — 4+x Redundant 64 — 5+x Redundant Default Value 0 — not applicable Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.RedundantState (Read Only) Table 457. Details of System.Power.RedundantState Description Retrieves the redundancy state for the chassis. NOTE: This object is not applicable for Rack and Tower server.
System.Power.Supply.FwVer (Read Only) Table 459. Details of System.Power.Supply.FwVer Description Displays the firmware version of the PSU. Legal Values String up to 254 ASCII characters. Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Supply.[i].MaxInputPower (Read Only) Table 460. Details of System.Power.Supply.[i].MaxInputPower Description Displays the AC input rated power in Watts.
Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable System.Power.Supply.[i].Type (Read Only) Table 463. Details of System.Power.Supply.[i].Type Description Displays whether the power supply is AC or DC. Either of them are indexed group and the square brackets are only place-holders, and do not form a part of command syntax. Legal Values String up to 32 characters.
System.QuickSync.Access (Read or Write) Table 466. Details of System.QuickSync.Access Description Configures the accessibility using Quick Sync on the server. Legal Values • • • Default Value 2 — Read-write Write Privilege Server Control 0 — Disabled 1 — Read-only 2 — Read-write License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the System.QuickSync.Presence property must indicate Present System.QuickSync.InactivityTimeout (Read or Write) Table 467. Details of System.
Dependency None System.QuickSync.ReadAuthentication (Read or Write) Table 470. Details of System.QuickSync.ReadAuthentication Description Enable or disable whether credentials are required when reading via Quick Sync. Legal Values • • Default value 1 - Enabled Write Privilege Configure iDRAC 0 - Disabled 1 - Enabled License Required iDRAC Express Dependency The values for System.QuickSync.Presence property must indicate Present System.QuickSync.WiFi (Read or Write) NOTE: The System.QuickSync.
System.ServerOS.OSName (Read or Write) Table 473. Details of System.ServerOS.OSName Description Displays the operating system name of the managed server. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ServerOS.OSVersion (Read Only) Table 474. Details of System.ServerOS.OSVersion Description Indicates the operating system version of the managed server.
System.Serverpwr This group provides power management features for iDRAC. The following section provides information about the objects in this group. System.Serverpwr.ActivePolicyName (Read Only) Table 477. Details of System.Serverpwr.ActivePolicyName attribute Description Displays the Active Power Cap Policy Name Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None System.Serverpwr.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None System.Serverpwr.PowerCapSetting Table 481. Details of System.Serverpwr.PowerCapSetting subcommand Description Enables or Disables setting the Power Cap value. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable 0 — Disabled. 1 — Enabled. License Required iDRAC Enterprise Dependency None System.Serverpwr.PowerCapValue Table 482. Details of System.Serverpwr.
System.storage.RemainingRatedWriteEnduranceAlertThre shold (Read or Write) Table 484. Details of System.storage.RemainingRatedWriteEnduranceAlertThreshold Description Displays the system level user configured threshold value for write endurance value of the SSD devices connected to system. Legal Values Integral Values: 1–99 Default Value 10 Write Privilege Configure iDRAC License Required iDRAC RACADM Dependency None System.
License Required Not Applicable Dependancy None System.SupportInfo.Type (Read or Write) Description Indicates whether a support request is for a problem with your system's network connectivity or with a particular system component. Legal Values • • 0-Network 1-Storage Default Values • 0 Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.SystemInfo This group contains the attributes that provides details about System.SystemInfo. System.SystemInfo.
System.SystemInfo.SysLocation (Read or Write) Description Alphanumeric text that specifies where the system is, such as building and room. Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.SystemInfo.SystemName (Read Only) Description Alphanumeric text that uniquely identifies the system.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.AirTemperatureRiseLimit (Read or Write) Description Defines the Air Temperature Rise Limit Legal Values • • • • • • • • 0-15 1-20 2-25 3-30 4-35 5-40 6-45 255-NO LIMIT Default Values • 255 Write Privilege Configure iDRAC License Required Not Applicable Dependancy Feature must be supported to set the value. System.ThermalSettings.
System.ThermalSettings.CurrentSystemProfileValue (Read Only) Description Displays current system profile value Legal Values None Default Values None Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.ThermalSettings.FanSpeedOffset (Read or Write) Table 487. Details of System.ThermalSettings.FanSpeedOffset Description Specifies the fan speed offset. NOTE: This attribute is platform dependent.
License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedHighOffsetVal (Read Only) Table 490. Details of System.ThermalSettings.FanSpeedHighOffsetVal Description Indicates the percentage range for the high fan offset speed. NOTE: This attribute is platform dependent. Legal Values Integral Values: 0 – 100 Default Value 0 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.FanSpeedHighOffsetVal (Read Only) Table 491.
System.ThermalSettings.MaximumPCIeInletTemperatureL imit (Read or Write) Description Defines the Maximum PCIe Inlet Temperature Limit. Legal Values • • 0-55 1-45 Default Values • 0 Write Privilege Configure iDRAC License Required Not Applicable Dependancy Feature must be supported to set the value. System.ThermalSettings.MaximumPCIeInletTemperatureL imitSupport (Read Only) Description Defines if the Maximum PCIe Inlet Temperature Limit configuration is supported.
Write Privilege Configure iDRAC License Required Not Applicable Dependancy Feature must be supported to set the value. System.ThermalSettings.SystemExhaustTemperature (Read Only) Description Indicates the current system exhaust temperature. Legal Values None Default Values • Write Privilege Configure iDRAC License Required Not Applicable Dependancy None 0 System.ThermalSettings.SystemInletTemperature (Read Only) Description Indicates the current system inlet (ambient) temperature.
Write Privilege Configure iDRAC License Required Not Applicable Dependancy None System.ThermalSettings.MFSMaximumLimit (Read Only) Table 493. Details of System.ThermalSettings.MFSMaximumLimit Description Indicates the maximum limit for MFS. NOTE: This attribute is platform dependent. Legal Values Integral Values: 1 - 100 Default Value 255 License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalSettings.MFSMinimumLimit (Read Only) Table 494. Details of System.
System.ThermalConfig.CriticalEventGenerationInterval (Read or Write) Table 496. Details of System.ThermalConfig.CriticalEventGenerationInterval Description Indicates the time interval (in days) for critical events to be generated. Legal Values Integral Values: 0-365 Default Value 30 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.ThermalConfig.EventGenerationInterval (Read or Write) Table 497. Details of System.ThermalConfig.
NOTE: This setting can be overwritten by BIOS Menu setting. Legal Values • • • Default Value 0—Not applicable Write privilege Configure iDRAC 0—Not applicable 1—Disabled 2—Enabled License Required Not Applicable Dependency None System.WarrantyInfo This group contains the attributes that provides details about System.WarrantyInfo. System.WarrantyInfo.Cost (Read or Write) Description The total cost of the warranty service on a system.
Legal Values • • 0-Days 1-Months Default Values • 0 Write Privilege Configure iDRAC License Required Not Applicable Dependancy None LifecycleController.LCAttributes The following section provides information about the objects in the LifecycleController.LCAttributes group. NOTE: A job successfully configured using the autoupdate or autobackup feature settings can be deleted only if the job is currently not running or downloading. LifecycleController.LCAttributes.
Legal Values • • Default Value 1 — Enabled Write Privilege Server Control 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.BiosRTDRequested (Read or Write) Table 503. Details of LifecycleController.LCAttributes.BiosRTDRequested Description Reset all the BIOS attributes to the default state. Set the value to 1, and restart the server to reset the BIOS attributes to factory default. After the server restart, the value is set to 0 by default.
• 1 — On Default Value 0 — Off Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None LifecycleController.LCAttributes.IgnoreCertWarning (Read and Write) Table 506. Details of LifecycleController.LCAttributes.IgnoreCertWarning Description Specifies to ignore Certificate Warning when HTTPS specified. Legal Values • • Default value 1—On Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None 0—Off 1—On LifecycleController.LCAttributes.
LifecycleController.LCAttributes.LifecycleControllerState (Read or Write) Table 509. Details of LifecycleController.LCAttributes.LifecycleControllerState Description Enables or disables lifecycle controller. Legal Values • • • Default Value 1 — Enabled Write Privilege Server Control 0 — Disabled 1 — Enabled 2 — Recovery (Read Only Value) License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.ProvisioningServer (Read or Write) Table 510.
LifecycleController.LCAttributes.PartFirmwareUpdate (Read or Write) Table 512. Details of LifecycleController.LCAttributes.PartFirmwareUpdate Description Apply firmware changes to the replaced part on part replacement. Legal Values 0 — Disabled 1 — Allow version upgrade only 2 — Match firmware of replaced part Default Value 2 — Match firmware of replaced part Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes.
Default value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None LifecycleController.LCAttributes. UserProxyServer (Read and Write) Table 516. Details of LifecycleController.LCAttributes.
LifecycleController.LCAttributes.VirtualAddressManagem entApplication (Read or Write) Table 519. Details of LifecycleController.LCAttributes.VirtualAddressManagementApplication Description Specifies the console name of Virtual Address Management Application. Legal Values String of up to 32 ACSII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.
iDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write) Table 522. Details of iDRAC.ActiveDirectory.DCLookupByUserDomain Description To look up the user domain for Active Directory, enables the selection option. Legal Values • • Default Value 0—Disabled Write Privilege Configure iDRAC and configure user 0—Disabled 1—Enabled License Required iDRAC Enterprise Dependency Cannot be disabled unless the DC Lookup Domain Name is set. iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write) Table 523.
iDRAC.ActiveDirectory.DomainController1 (Read or Write) Table 525. Details of iDRAC.ActiveDirectory.DomainController1 Description FQDN that stores the address of the active directory domain controller1. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.DomainController2 (Read or Write) Table 526. Details of iDRAC.ActiveDirectory.
Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.GCLookupEnable (Read or Write) Table 529. Details of iDRAC.ActiveDirectory.GCLookupEnable Description Determines how to look up the global catalog server.
Dependency None iDRAC.ActiveDirectory.GlobalCatalog2 (Read or Write) Table 532. Details of iDRAC.ActiveDirectory.GlobalCatalog2 Description To obtain user names, specifies the Global Catalog server from which you want the iDRAC. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC and configure user License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.GlobalCatalog3 (Read or Write) Table 533. Details of iDRAC.
Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.Schema (Read or Write) Table 536. Details of iDRAC.ActiveDirectory.Schema Description To use with Active Directory, determine the schema type. Legal Values • • Default Value 1—Extended Schema Write Privilege Configure iDRAC and configure user 1—Extended Schema 2 —Standard Schema License Required iDRAC Enterprise Dependency None iDRAC.ActiveDirectory.
License Required iDRAC Enterprise Dependency None iDRAC.ADGroup.Name (Read or Write) Table 539. Details of iDRAC.ADGroup.Name Description Name of the Role Group as recorded in the Active Directory forest. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.ADGroup.Privilege (Read or Write) Table 540. Details of iDRAC.ADGroup.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.EmailAlert The objects in this group configure email alerting capabilities. This group is indexed from 1 to 4. iDRAC.EmailAlert.Address (Read or Write) Table 542. Details of iDRAC.EmailAlert.Address Description Specifies the destination email address for email alerts.
iDRAC.GroupManager The objects in this group helps to add or delete the group from group manager. iDRAC.GroupManager.Status NOTE: The iDRAC.GroupManager.Globalstate command is deprecated and replaced with iDRAC.GroupManager.Status command. Table 545. Details of iDRAC.GroupManager.Status Description Enables or disables Group Management. Legal Values • • Default Value 0- Disabled Write Privilege Configure iDRAC 0- Disabled 1- Enabled License Required Group Manager Dependency None iDRAC.
iDRAC.GUI The objects in this group helps to set security policy banner string. iDRAC.GUI.SecurityPolicyMessage (Read or Write) Table 548. Details of iDRAC.GUI.SecurityPolicyMessage Description To Get / Set Security Policy Banner String Legal Values A string of upto 1024 Unicode character bytes Default Value Not Applicable Write Privilege Configure iDRAC License Required None Dependency None iDRAC.Info To manage information about iDRAC being queried, use these objects in the group. iDRAC.Info.
iDRAC.Info.Name (Read or Write) Table 551. Details of iDRAC.Info.Name Description User assigned name identifying this controller. Legal Values String of up to 15 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Info.Product (Read or Write) Table 552. Details of iDRAC.Info.Product Description String identifying the Product.
iDRAC.Info.ServerGen (Read or Write) Table 555. Details of iDRAC.Info.ServerGen Description Indicates the server generation. Legal Values String of up to 12 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IOIDOpt The objects in this group manage the IOIDOpt attributes. iDRAC.IOIDOptEnable (Read or Write) Table 556. Details of iDRAC.
iDRAC.IOIDOpt.StorageTargetPersistencePolicy (Read or Write) Table 558. Details of iiDRAC.IOIDOpt.StorageTargetPersistencePolicy Description Sets the Virtual Address Management StorageTargetPersistencePolicy.
• • • • • 3 — WarmReset, PowerGoodReset 4 — ACPowerLoss 5 — WarmReset, ACPowerLoss 6 — PowerGoodReset, ACPowerLoss 7 — WarmReset, PowerGoodReset, ACPowerLoss Default Value ACPowerLoss, PowerGoodReset, WarmReset Write Privilege Login, configure, and server control License Required iDRAC Express or iDRAC Enterprise Dependency To configure, the iDRAC.IOIDOpt.Enable property must indicate Enabled. iDRAC.IPBlocking To configure IP address blocking feature of iDRAC, Use the objects in this group. iDRAC.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.PenaltyTime (Read or Write) Table 564. Details of iDRAC.IPBlocking.PenaltyTime Description Defines the time span in seconds that session requests from an IP address with excessive failures are rejected. Legal Values Integral values: 2–65535 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPBlocking.RangeAddr (Read or Write) Table 565. Details of iDRAC.
Legal Values Valid IPv4 Address Mask Default Value 255.255.255.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan To configure IPMI over LAN of the system, use the objects in this group. iDRAC.IPMILan.AlertEnable (Read or Write) Table 568. Details of iDRAC.IPMILan.AlertEnable Description Enables or disables global email alerting.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMILan.EncryptionKey (Read or Write) Table 571. Details of iDRAC.IPMILan.EncryptionKey Description Enables or disables the IPMI over LAN interface. Legal Values String of up to 18 ASCII characters Default Value 0000000000000000000000000000000000000000 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
• • • 19200 57600 115200 Default Value 115200 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.ChanPrivLimit (Read or Write) Table 574. Details of iDRAC.IPMISerial.ChanPrivLimit Description Specifies the maximum privilege limit allowed on the IPMI serial channel.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.EchoControl (Read or Write) Table 577. Details of iDRAC.IPMISerial.EchoControl Description Enables or disables echo control on the IPMI serial interface. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.FlowControl (Read or Write) Table 578.
iDRAC.IPMISerial.InputNewLineSeq (Read or Write) Table 580. Details of iDRAC.IPMISerial.InputNewLineSeq Description Specifies the input new line sequence for the IPMI serial interface. Legal Values • • Default Value 2 — Null Write Privilege Configure iDRAC 1 — Enter 2 — Null License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISerial.LineEdit (Read or Write) Table 581. Details of iDRAC.IPMISerial.
iDRAC.IPMISOL Use the objects in this group to configure the SOL capabilities of the system. iDRAC.IPMISOL.AccumulateInterval (Read or Write) Table 583. Details of iDRAC.IPMISOL.AccumulateInterval Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. Legal Values Integral values: 1–255 Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPMISOL.
iDRAC.IPMISOL.MinPrivilege (Read or Write) Table 586. Details of iDRAC.IPMISOL.MinPrivilege Description Specifies the minimum privilege level required for serial access. Legal Values • • • Default Value 4—Administrator Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 2—User 3—Operator 4—Administrator iDRAC.IPMISOL.SendThreshold (Read or Write) Table 587. Details of iDRAC.IPMISOL.
iDRAC.IPv4.DHCPEnable (Read or Write) Table 589. Details of iDRAC.IPv4.DHCPEnable Description Specifies if DHCP is used to assign the iDRAC IPv4 address. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Cannot be enabled unless IPv4.Enable is enabled. iDRAC.IPv4.DNS1 (Read or Write) Table 590. Details of iDRAC.IPv4.DNS1 Description IPv4 address for DNS server 1.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4.Enable (Read or Write) Table 593. Details of iDRAC.IPv4.Enable Description Enables or disables the iDRAC IPv4 stack. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4.Gateway (Read or Write) Table 594. Details of iDRAC.IPv4.
iDRAC.IPv4Static Use the objects in this group to manage the IPv4 Static configuration properties of iDRAC. iDRAC.IPv4Static.Address (Read or Write) Table 596. Details of iDRAC.IPv4Static.Address Description iDRAC static IPv4 address. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 Address Default Value 192.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv4Static.DNS1 (Read or Write) Table 597.
iDRAC.IPv4Static.DNSFromDHCP (Read or Write) Table 599. Details of iDRAC.IPv4Static.DNSFromDHCP Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — Disabled 1 — Enabled iDRAC.IPv4Static.Gateway (Read or Write) Table 600. Details of iDRAC.IPv4Static.
Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 2 (Read or Write) Table 603. Details of iDRAC.IPv6.Address 2 Description iDRAC IPv6 second address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 3 (Read or Write) Table 604. Details of iDRAC.IPv6.
iDRAC.IPv6.Address 5 (Read or Write) Table 606. Details of iDRAC.IPv6.Address 5 Description iDRAC IPv6 fifth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 6 (Read or Write) Table 607. Details of iDRAC.IPv6.Address 6 Description iDRAC IPv6 sixth address.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address 9 (Read or Write) Table 610. Details of iDRAC.IPv6.Address 9 Description iDRAC IPv6 ninth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address10 (Read or Write) Table 611. Details of iDRAC.IPv6.Address10 Description iDRAC IPv6 tenth address.
Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address13 (Read or Write) Table 614. Details of iDRAC.IPv6.Address13 Description iDRAC IPv6 thirteenth address. Legal Values Valid IPv6 Address Default Value :: Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Address14 (Read or Write) Table 615. Details of iDRAC.IPv6.
iDRAC.IPv6.AutoConfig (Read or Write) Table 617. Details of iDRAC.IPv6.AutoConfig Description Enables or disables the iDRAC IPv6 auto configuration option. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.DNS1 (Read or Write) Table 618. Details of iDRAC.IPv6.DNS1 Description IPv6 DNS Server 1 Address.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Enable (Read or Write) Table 621. Details of iDRAC.IPv6.Enable Description Enables or Disables iDRAC IPv6 stack. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6.Gateway (Read or Write) Table 622. Details of iDRAC.IPv6.
iDRAC.IPv6.PrefixLength (Read or Write) Table 624. Details of iDRAC.IPv6.PrefixLength Description Prefix length for the iDRAC IPv6 Address. Legal Values Integral values: 1–128 Default Value 64 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static To manage the IPv6 static configuration properties of iDRAC, use the objects in this group iDRAC.IPv6Static.Address1 (Read or Write) Table 625. Details of iDRAC.IPv6Static.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.DNSFromDHCP6 (Read or Write) Table 628. Details of iDRAC.IPv6Static.DNSFromDHCP6 Description Specifies if the DNS server IPv6 addresses must be assigned from the DHCP server on the network. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.IPv6Static.
iDRAC.IPv6URL.URL (Read Only) Table 631. Details of iDRAC.IPv6URL.URL Description iDRAC IPv6 URL String of format 'https://[ipv6 address]:' Legal Values IPv6 URL String Default Value Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency iDRAC IPv6 has to be Enabled iDRAC.LDAP To configure properties for LDAP settings, use the objects in this group. iDRAC.LDAP.BaseDN (Read or Write) Table 632. Details of iDRAC.LDAP.
Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.CertValidationEnable (Read or Write) Table 635. Details of iDRAC.LDAP.CertValidationEnable Description Controls certificate validation during SSL handshake. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.LDAP.
iDRAC.LDAP.GroupAttributeIsDN (Read or Write) Table 638. Details of iDRAC.LDAP.GroupAttributeIsDN Description Specifies whether the user domain name must be used from the LDAP server or from the user that provides login. Legal Values 0 — Disabled 1 — Enabled Default Value 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.Port (Read or Write) Table 639. Details of iDRAC.LDAP.Port Description Port of LDAP over SSL.
Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.LDAP.UserAttribute (Read or Write) Table 642. Details of iDRAC.LDAP.UserAttribute (Read or Write) Description To search, specify the user attribute. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.
Dependency None iDRAC.LocalSecurity To manage the ability to configure iDRAC, use the objects in this group. iDRAC.LocalSecurity.LocalConfig (Read or Write) NOTE: The iDRAC.LocalSecurity.LocalConfigDisabled attribute is deprecated and replaced with iDRAC.LocalSecurity.LocalConfig attribute. Table 645. Details of the iDRAC.LocalSecurity.LocalConfig attribute Description To configure iDRAC from Local RACADM, enable or disable the ability of the local user.
Default Value 0- Circular Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Table 648. Details of the iDRAC.Logging.SELOEMEventFilterEnable attribute Description Enables or disables the ability of Logging SEL Records with OEM.
Legal Values • • Default Value 0 — Disabled Write Privilege Login, configure, and server control 0 — Disabled: It disables the lockdown mode. In this mode, the iDRAC configuration changes are allowed. 1 — Enabled: It enables the lockdown mode. In this mode, the iDRAC configuration changes are not allowed. License Required iDRAC Enterprise Dependency None iDRAC.NIC To configure the iDRAC NIC, use the object in this group.
Default Value 0 — Disabled Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.Autoneg (Read or Write) Table 652. Details of the iDRAC.NIC.Autoneg attribute Description Enables auto-negotiation of physical link speed and duplex. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.
iDRAC.NIC.DNSDomainFromDHCP (Read or Write) Table 655. Details of the iDRAC.NIC.DNSDomainFromDHCP attribute Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server. Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency Can be Enabled only if the following are enabled: • • IPv4.Enable and IPv4.DHCPEnable IPv6.Enable and IPv6.AutoConfig iDRAC.NIC.
Legal Values String of up to 63 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.DNSRegister (Read or Write) Table 659. Details of the iDRAC.NIC.DNSRegister attribute Description Registers the iDRAC name with the DNS server.
Dependency None iDRAC.NIC.Failover (Read or Write) Table 662. Details of iDRAC.NIC.Failover attribute Description Enables or disables failover for iDRAC to switch from shared to dedicated. Legal Values LOM1 to LOM16 Default Value None Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NIC.MACAddress (Read or Write) Table 663. Details of the iDRAC.NIC.MACAddress attribute Description The MAC Address of the iDRAC.
Legal Values • • • • • • • • Default Value 1 — Dedicated Write Privilege Configure iDRAC 1 — Dedicated 2 — LOM1 3 — LOM2 4 — LOM3 5 — LOM4 6 — LOM5 7 — LOM6 8 — LOM7 License Required iDRAC Express or iDRAC Enterprise Dependency None NOTE: On platforms with single LOM port, the legal values are applicable. NOTE: For cosmos platform, NIC selection will be applied on next host reboot. iDRAC.NIC.SharedNICScanTime (Read or Write) Table 666. Details of the iDRAC.NIC.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency Cannot change NIC Speed unless AutoNeg is set to disabled. iDRAC.NIC.VLanEnable (Read Only) Table 668. Details of the iDRAC.NIC.VLanEnable attribute Description Enables or disables the VLAN capabilities of the iDRAC. NOTE: This object is applicable only to iDRAC on Racks and Towers.
Dependency None iDRAC.NIC.VLanPriority (Read Only) Table 671. Details of the iDRAC.NIC.VLanPriority attribute Description Specifies the VLAN priority for the network VLAN configuration. NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values Integral values: 0–7 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NICStatic To manage DNS-related properties of iDRAC, use the objects in this group. iDRAC.
iDRAC.NTPConfigGroup To configure the properties of NTP server, use the objects in this group. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Table 674. Details of the iDRAC.NTPConfigGroup.NTP1attribute Description Configure NTP Server 1 Address. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTP2 (Read or Write) Table 675.
Legal Values • • Default Value 0 — Disabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write) Table 678. Details of the iDRAC.NTPConfigGroup.NTPMaxDist attribute Description NTP Maximum Distance Legal Values Integral values: 1–128 Default Value 16 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.OS-BMC.OSIpAddress (Read or Write) Table 680. Details of the iDRAC.OS-BMC.OSIpAddress attribute Description IPv4 address of the host Operating System. Legal Values Valid IPv4 Address Default Value 0.0.0.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.OS-BMC.PTCapability (Read or Write) Table 681. Details of the iDRAC.OS-BMC.PTCapability attribute Description Operating System to iDRAC Pass Through Capability status.
Legal Values Valid IPv4 address Default Value 169.168.0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.RemoteHost.SMTPPort (Read or Write) Table 684. Details of the iDRAC.RemoteHost.SMTPPort attribute Description Specifies the destination port for email alerts. Legal Values Integral values: 1–65535 Default Value 25 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.PcieVdm.Enable Table 685.
iDRAC.Racadm.Timeout (Read or Write) Table 687. Details of the iDRAC.Racadm.Timeout attribute Description Defines the idle timeout in seconds of the Remote RACADM interface. Legal Values • • Default Value 60 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None 0 — No timeout Integral values: 60–10800 iDRAC.Redfish The objects in this group provide configuration parameters for the Redfish interface to iDRAC. iDRAC.Redfish.
Dependency None iDRAC.Redfisheventing.DeliveryRetryIntervalInSeconds (Read or Write) Table 690. Details of the iDRAC.Redfisheventing.DeliveryRetryIntervalInSeconds attribute Description Specifies the intervals (in seconds) of retry attempts made for Redfish event delivery. Legal Values Value ranges from 5 to 60. Default Value 30 Write Privilege Configure iDRAC License Required RACADM Dependency None iDRAC.Redfisheventing.IgnoreCertificateErrors (Read Only) Table 691. Details of the iDRAC.
iDRAC.RemoteHost.SMTPPort (Read or Write) Table 693. Details of the iDRAC.RemoteHost.SMTPPort attribute Description Specifies the destination port for email alerts. Legal Values Integral values: 1–65535 Default Value 25 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.RemoteHosts.SMTPServerIPAddress (Read or Write) Table 694. Details of the iDRAC.RemoteHosts.SMTPServerIPAddress attribute Description IPv4 or IPv6 address of the network SMTP server.
iDRAC.RFS.MediaAttachState (Read Only) Table 696. Details of the iDRAC.RFS.MediaAttachState attribute Description RFS Media attach state. Legal Values • • Default Value 1 — Detached Write Privilege Not Applicable 0 — Attached 1 — Detached License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.RSM The objects in this group manage the Rack Style Management (RSM) settings. iDRAC.RSM.RSMCapability (Read Only) Table 697. Details of the iDRAC.RSM.
iDRAC.Security.CsrCommonName (Read or Write) Table 699. Details of iDRAC.Security.CsrCommonName attribute Description Specifies the CSR Common Name (CN) that must be an IP as given in the certificate. Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrCountryCode (Read or Write) Table 700. Details of iDRAC.Security.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrLocalityName (Read or Write) Table 703. Details of iDRAC.Security.CsrLocalityName Description Specifies the CSR Locality (L). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrOrganizationName (Read or Write) Table 704.
iDRAC.Security.CsrStateName (Read or Write) Table 706. Details of iDRAC.Security.CsrStateName Description Specifies the CSR State Name (S). Legal Values String of up to 254 ASCII characters Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Security.CsrSubjectAltName (Read or Write) Table 707. Details of iDRAC.Security.CsrSubjectAltName Description Specifies the CSR Subject Alternative Name.
iDRAC.Serial.BaudRate (Read or Write) Table 709. Details of iDRAC.Serial.BaudRate Description Sets the Baud rate on the iDRAC serial port. Legal Values • • • • Default Value 115200 Write Privilege Configure iDRAC 9600 19200 57600 115200 License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.Command (Read or Write) Table 710. Details of iDRAC.Serial.Command Description Specifies a serial command that is executed after the user logs in to the serial console interface.
Legal Values Integral values from 0 to 8192. Default Value 8192 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Serial.IdleTimeout (Read or Write) Table 713. Details of iDRAC.Serial.IdleTimeout Description The maximum number of seconds to wait before an idle serial console session is disconnected.
Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SerialRedirection.QuitKey (Read or Write) Table 716. Details of iDRAC.SerialRedirection.QuitKey Description This key or key combination terminates the Virtual Console when using the console COM2 command. Legal Values The value must start with the ^ character, and must follow one of the characters a-z, A-Z, [,], \, ^, _ enclos
• • • • • • • • • • • • • PXE HDD (Hard Disk Drive) CD-DVD (Local CD/DVD) BIOS (BIOS Setup) vFDD (Virtual Floppy) VCD-DVD (Virtual CD/DVD/ISO) FDD (Local Floppy/Primary Removable Media) SD (Local SD Card) F10 (Lifecycle Controller) F11 (BIOS Boot Manager) UEFIDevicepath UEFIHttp Attached vFlash Partition Label Default value Normal Write Privilege Login and configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.
iDRAC.ServiceModule.LCLReplication (Read or Write) Table 721. De\tails of iDRAC.ServiceModule.LCLReplication Description Enables Lifecycle log in operating system log Baud rate on the iDRAC serial port. Legal Values • • Default Value 0 — Disabled Write Privilege Login, configure, and server control 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency If OpenManage Server Administrator is available, then the attribute is automatically set to ‘Disabled’. iDRAC.
Default Value 1 — Enabled Write Privilege Login, configure, and server control License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.ServiceModule.ServiceModuleState (Read or Write) Table 725. The details of iDRAC.ServiceModule.ServiceModuleState Description Indicates the status of Service Module process on the host operating system.
iDRAC.ServiceModule.WatchdogResetTime (Read and Write) Table 728. The details of iDRAC.ServiceModule.WatchdogResetTime Description Configures the system reset time (unit in seconds) on watchdog alert. Legal Values Values in range 60–720 Default Value 480 Write Privilege Login, configure, and server control License Required iDRAC Express or iDRAC Enterprise Dependency If the iDRAC.ServiceModule.WatchdogState object is ‘Disabled’, then the value cannot be set. iDRAC.ServiceModule.
Legal Values • • • Default Value Not Applicable Write Privilege Configure iDRAC and Configure User 0 — Disabled 1 — Enabled 2 — Enabled with Remote RACADM License Required iDRAC Enterprise Dependency Disable ActiveDirectory.SSOEnable iDRAC.SNMP The objects in this group enable you to configure the SNMP agent and trap capabilities. iDRAC.SNMP.AgentCommunity (Read or Write) Table 732. Details of iDRAC.SNMP.
License Required iDRAC Express Dependency None iDRAC.SNMP.DiscoveryPort (Read or Write) Table 735. Details of iDRAC.SNMP.DiscoveryPort Description Specifies the SNMP agent port on iDRAC. Legal Values Integral values: 1–65535 Default Value 161 Write Privilege Configure iDRAC License Required iDRAC Express Dependency None iDRAC.SNMP.SNMPProtocol (Read or Write) Table 736. Details of iDRAC.SNMP.SNMPProtocol Description Specifies the SNMP protocol.
iDRAC.SupportAssist.DefaultIPAddress Table 738. Details of the iDRAC.SupportAssist.DefaultIPAddress attribute Description Default workgroup name for saving SupportAssist collections to network share. Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency None iDRAC.SupportAssist.DefaultWorkgroupName Table 739. Details of the iDRAC.SupportAssist.
iDRAC. SupportAssist.DefaultShareName Table 742. Details of iDRAC. SupportAssist.DefaultShareName Description Default password for saving SupportAssist collections to network share. Legal Values String of 0 to 64 characters length Default Value NA License Required RACADM Dependency None iDRAC.SupportAssist.DefaultUserName Table 743. Details of iDRAC.SupportAssist.DefaultUserName Description Default user name for saving SupportAssist collections to network share.
iDRAC.SupportAssist.FilterAutoCollections Table 746. Details of iDRAC.SupportAssist.FilterAutoCollections Description Option to receive E-mails from Dell on case creation and collection upload. Legal Values 0 - No 1-Yes Default Value 0 - No License Required RACADM Dependency Registration ID needs to be obtained before Email option configuration. iDRAC.SupportAssist.HostOSProxyAddress Table 747. Details of iDRAC.SupportAssist.HostOSProxyAddress Description Host OS proxy address.
iDRAC.SupportAssist.HostOSProxyPort Table 750. Details of iDRAC.SupportAssist.HostOSProxyPort Description Host OS proxy port. Legal Values Integer values from 0 to 65535. Default Value NA License Required RACADM Dependency HostOSProxyConfigured should be 1=Yes iDRAC.SupportAssist.HostOSProxyUserName Table 751. Details of iDRAC.SupportAssist.HostOSProxyUserName Description Host OS proxy password.
iDRAC.SupportAssist.ProSupportPlusRecommendationsR eport Table 754. Details of iDRAC.SupportAssist.ProSupportPlusRecommendationsReport Description Indicates whether this server will be included for recommendations in ProSupport Plus Recommendations Report. Legal Values 0-Disabled, 1-Enabled Default Value 0-Disabled License Required RACADM Dependency ScheduleBasedAutoCollection should be enabled and set to weekly or monthly schedule. iDRAC.SupportAssist.RegistrationID Table 755. Details of iDRAC.
Legal Values Valid IPv4 or IPv6 or FQDN address Default Value • • Write Privilege Configure iDRAC Index 1–4—0.0.0.0 Index 5–8—:: License Required None Dependency None iDRAC.SNMPAlert.Enable (Read or Write) Table 758. Details of the iDRAC.SNMPAlert.Enable attribute Description Enables or disables SNMP alert for the given index. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC 0—Disabled 1—Enabled License Required None Dependency None iDRAC.SNMPAlert.
iDRAC.SSH The objects in this group provide configuration parameters for the SSH interface to iDRAC. iDRAC.SSH.Enable (Read or Write) Table 761. Details of the iDRAC.SSH.Enable attribute Description Enables or disables SSH. Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.SSH.Port (Read or Write) Table 762. Details of the iDRAC.SSH.
iDRAC.SwitchConnectionView (Read Only) Table 764. Details of the iDRAC.SwitchConnectionView attribute Description Allows you to enable or disable switch connection. Legal Values • • Default Value 1 — Enabled Write Privilege Not Applicable 0 — Disabled 1 — Enabled License Required Not Applicable Dependency None iDRAC.SysLog The objects in this group provide the properties for configuration of the SMTP server. iDRAC.SysLog.Port (Read or Write) Table 765. Details of iDRAC.SysLog.
iDRAC.SysLog.PowerLogInterval (Read or Write) Table 767. Details of iDRAC.SysLog.PowerLogIntervalattribute Description Configure time delay for power logging. Legal Values Integral values: 1–1440 Default Value 5 Write Privilege Configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.SysLog.Server1 (Read or Write) Table 768. Details of iDRAC.SysLog.Server1 attribute Description Name of remote syslog server 1.
License Required iDRAC Enterprise Dependency None iDRAC.SysLog.SysLogEnable (Read or Write) Table 771. Details of iDRAC.SysLog.SysLogEnableattribute Description Enables or disables remote syslog. Legal Values • • Default Value Not Applicable Write Privilege Configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.Telnet The objects in this group provide configuration parameters for the Telnet interface to iDRAC. iDRAC.Telnet.
iDRAC.Telnet.Timeout (Read or Write) Table 774. Details of iDRAC.Telnet.Timeout attribute Description Defines the Telnet idle timeout. Legal Values Integral values: 0–10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Time The objects in this group enable you to manage time zone setting for iDRAC. iDRAC.Time.DayLightOffset (Read or Write) Table 775. Details of iDRAC.Time.
Legal Values Integral values: -43200 to 46800 Default Value 0 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.DefaultCredentialMitigationConfigGroup NOTE: The iDRAC.Tuning group is deprecated and replaced with iDRAC.DefaultCredentialMitigationConfigGroup group. The objects in this group enable you to manage iDRAC tuning and configuration parameters. iDRAC. DefaultCredentialMitigationConfigGroup.
Dependency None iDRAC.Update.FwUpdatePath (Read or Write) Table 780. Details of iDRAC.Update.FwUpdatePath attribute Description Specifies TFTP path where iDRAC firmware image resides on TFTP server. Path is relative to TFTP root folder. Legal Values String of up to 255 ACSII characters. For example: /images/12G/ Default Value Not Applicable Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Update.FwUpdateTFTPEnable (Read or Write) Table 781.
iDRAC.USB.ManagementPortMode (Read only) Table 783. Details of iDRAC.USB.ManagementPortMode attribute Description Displays the front panel USB mode. NOTE: The behaviour and legal values of this attribute differs from 13G to 14G. Legal Values • Default Value iDRAC Direct Only Write Privilege Not Applicable iDRAC Direct Only License Required iDRAC Express and iDRAC Enterprise Dependency Not Applicable iDRAC.USB.PortStatus Table 784. Details of iDRAC.USB.
Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users The objects in this group enable you to manage information about all iDRAC users. This group is indexed from 1 to 16. iDRAC.Users.Enable (Read or Write) Table 787. Details of iDRAC.Users.Enable attribute Description Enables or disables an individual user. Legal Values • • Default Value 0 — Disabled. However, Root user is Enabled.
• • • • 2 — User 3 — Operator 4 — Administrator 15 — No access Default Value 15 — No access Write Privilege Configure iDRAC and user License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to setting this object. iDRAC.Users.MD5v3Key (Read or Write) Table 790. Details of iDRAC.Users.MD5v3Key attribute Description Indicates the MD5 Hash of the SNMP V3 key.
iDRAC.Users.SHA256PasswordSalt (Read or Write) Table 793. Details of iDRAC.Users.SHA256PasswordSalt attribute Description Indicates the Salt string added to password before hash. Legal Values String of 32 characters Write Privilege Configure iDRAC and Configure User License Required iDRAC Express Dependency User name must be configured prior to setting this object. iDRAC.Users.Privilege (Read or Write) Table 794. Details of iDRAC.Users.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Users.ProtocolEnable (Read or Write) NOTE: The iDRAC.Users.SNMPv3AuthenticationType attribute is deprecated and replaced with iDRAC.Users.ProtocolEnable attribute. Table 797. Details of iDRAC.Users.ProtocolEnable attribute Description Enables or disables SNMPv3 support for an iDRAC user.
License Required iDRAC Express or iDRAC Enterprise Dependency Both username and password must be configured prior to sets. iDRAC.Users.UserName (Read or Write) Table 800. Details of iDRAC.Users.UserName attribute Description iDRAC user name. NOTE: If there is a space character in the user name, enter the user name in quotes ("user name").
iDRAC.vflashpartition.EmulationType (Read or Write) Table 803. Details of iDRAC.vflashpartition.EmulationType attribute Description Specifies the emulation type of the vFlash SD partition. Legal Values • • • Default value None Write Privilege Login and configure iDRAC HDD FLOPPY CD-DVD License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashpartition.FormatType (Read or Write) Table 804. Details of iDRAC.
License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. Partition at the specified index must be created. iDRAC.vflashsd The objects in this group manage vFlash SD properties on iDRAC. iDRAC.vflashsd.AvailableSize (Read or Write) Table 807. Details of iDRAC.vflashsd.AvailableSize attribute Description Displays the available memory (in MB) on the vFlash SD card that is used to create new partitions. Legal Values Integer value in MB.
iDRAC.vflashsd.Initialized (Read or Write) Table 810. Details of iDRAC.vflashsd.Initialized attribute Description Specifies if the vFlash SD card is initialized or not. Legal Values • • Default value None Write Privilege Login and configure iDRAC 0 — Not Initialized 1 — Initialized License Required iDRAC Enterprise Dependency vFlash SD card must be enabled. iDRAC.vflashsd.Licensed (Read or Write) Table 811. Details of iDRAC.vflashsd.
iDRAC.VirtualConsole The objects in this group enable you to manage virtual console configuration parameters of iDRAC. iDRAC.VirtualConsole.AccessPrivilege (Read or Write) Table 814. Details of iDRAC.VirtualConsole.AccessPrivilege attribute Description Default action upon session sharing request timeout.
iDRAC.VirtualConsole.EncryptEnable (Read or Write) Table 817. Details of iDRAC.VirtualConsole.EncryptEnable (Read or Write) Description Encrypts the video in a Virtual Console session. Legal Values • • Default Value Enabled Write Privilege Configure iDRAC 0 - Disabled 1 - Enabled License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.LocalVideo (Read or Write) Table 818. Details of iDRAC.VirtualConsole.
Legal Values • • • Default Value 0 — Active X Write Privilege Configure iDRAC 0 — Active X 1 — Java 2 — HTML5 License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualConsole.Port (Read or Write) Table 821. Details of iDRAC.VirtualConsole.Port attribute Description Specifies the virtual KVM port.
• • 1 — Attached 2 — AutoAttach Default Value 2 — AutoAttach Write Privilege Virtual Media License Required iDRAC Express (For Blades) or iDRAC Enterprise Dependency None iDRAC.VirtualMedia.BootOnce (Read or Write) Table 824. Details of iDRAC.VirtualMedia.BootOnce attribute Description Enables or disables the virtual media boot once feature of the iDRAC.
• 1 Default value 0 Write Privilege Not Applicable License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.Enable (Read or Write) Table 827. Details of iDRAC.VNCServer.Enable attribute Description Enables or disables VNC server on iDRAC. Legal Values • • Default value 0 — Disabled Write Privilege Login or configure iDRAC 0 — Disabled 1 — Enabled License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.LowerEncryptionBitLength (Read or Write) Table 828. Details of iDRAC.
iDRAC.VNCServer.Port (Read or Write) Table 830. Details of iDRAC.VNCServer.Port attribute Description Port number for VNC session Legal Values Integer values from 1024 to 65535 Default Value 5901 Write Privilege Login or configure iDRAC License Required iDRAC Enterprise Dependency None iDRAC.VNCServer.SSLEncryptionBitLength (Read or Write) Table 831. Details of iDRAC.VNCServer.SSLEncryptionBitLength attribute Description Indicates the VNC server encryption state.
For example DEFAULT:CAMELLIA NOTE: These strings are case sensitive Legal Values String of up to 512 ASCII characters Default Value None Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.Enable (Read or Write) Table 834. Details of iDRAC.WebServer.Enable attribute Description Enables or disables the iDRAC web server.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.Webserver.Httpsredirection (Read or Write) Table 837. Details of iDRAC.Webserver.Httpsredirection attribute Description Enables or disables redirection from the http port (default — 80) to https (default — 443). Legal Values • • Default Value 1 — Enabled Write Privilege Configure iDRAC 1 — Enabled 0 — Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.
License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.Timeout (Read or Write) Table 840. Details of iDRAC.WebServer.Timeout attribute Description Defines the webserver timeout. Legal Values Integral values: 60–10800 Default Value 1800 Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None iDRAC.WebServer.TLSProtocol (Read or Write) Table 841. Details of iDRAC.WebServer.
NOTE: If BootMode is set to UEFI, legacy boot settings are not available in the system. Similarly, if BootMode is set to Legacy BIOS, UEFI settings are not available in the system. BIOS.BiosBootSettings.BootMode (Read or Write) Table 843. The details of BIOS.BiosBootSettings.BootMode attribute Description Determines the start mode of the system.
BIOS.BiosBootSettings.HddSeq (Read or Write) Table 846. The details of BIOS.BiosBootSettings.HddSeq attribute Description HDD boot sequence Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if Boot mode is set to UEFI BIOS.BiosBootSettings.UefiBootSeq (Read or Write) Table 847. The details of BIOS.BiosBootSettings.
Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices You can use the objects in this group to manage the integrated devices such as internal NIC and integrated USB. BIOS.IntegratedDevices.EmbNic1 (Read or Write) Table 850. The details of BIOS.IntegratedDevices.EmbNic1 attribute Description Enables or disables the operating system interface of the embedded NIC1.
• Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbNic3 (Read or Write) Table 853. The details of BIOS.IntegratedDevices.EmbNic3 attribute Description Enables or disables the operating system interface of the embedded NIC3.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Table 856. The details of BIOS.IntegratedDevices.EmbVideoattribute Description Enables or disables the BIOS support for the embedded video controller. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.
BIOS.IntegratedDevices.IntegratedNetwork2 (Read or Write) Table 859. The details of attribute Description Enables or disables the integrated network card 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled DisabledOS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IntegratedRaid (Read or Write) Table 860. The details of BIOS.IntegratedDevices.
Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalSdCardRedundancy (Read or Write) Table 863. The details of BIOS.IntegratedDevices.InternalSdCardRedundancy attribute Description Sets the SD Card redundancy mode.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.InternalUsb2 (Read or Write) Table 866. The details of BIOS.IntegratedDevices.InternalUsb2 attribute Description Enables or disables the internal USB port 2. Legal Values • • Default Value Not Applicable Write Privilege Server Control On Off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.IntegratedDevices.IoatEngine (Read or Write) Table 867. The details of BIOS.IntegratedDevices.
BIOS.IntegratedDevices.MmioAbove4GB (Read or Write) Table 869. The details of BIOS.IntegratedDevices.MmioAbove4GB attribute Description Enables or disables support for PCIe devices that require large amount of memory. Enable this option only for 64-bit operating systems. Legal Values • • Default Value Not Applicable Write Privilege iDRAC Express or iDRAC Enterprise Dependency None Enabled Disabled BIOS.IntegratedDevices.OsWatchdogTimer (Read or Write) Table 870. The details of BIOS.
BIOS.IntegratedDevices.UsbPorts (Read or Write) Table 872. The details of BIOS.IntegratedDevices.UsbPorts attribute Description Sets the user accessible USB ports. Legal Values • • • Default Value Not Applicable Write Privilege Server Control All on Only back ports on All off License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.EmbServerMgmt The objects in this group assist in embedded server management. BIOS.EmbServerMgmt.FrontLcd (Read or Write) Table 873.
BIOS.MemSettings.MemLowPower (Read or Write) Table 875. The details of BIOS.MemSettings.MemLowPower (Read or Write)attribute Description Enables or disables the low-power mode of the memory. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.MemOpMode (Read or Write) Table 876. The details of BIOS.MemSettings.MemOpMode attribute Description Current memory operating mode.
BIOS.MemSettings.MemOpVoltage (Read Only) Table 878. The details of BIOS.MemSettings.MemOpVoltage attribute Description Operating voltage of memory. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable AutoVolt Volt15V License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.MemTest (Read or Write) Table 879. The details of attribute Description Specifies whether BIOS software-based system memory tests are conducted during POST.
• • • • • Write Privilege Spare Mirror IntraNodeMirror DimmSpare Dddc Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMemCfgValid (Read or Write) Table 882. The details of attribute Description Redundant Memory Configuration Valid Legal Values • • Default Value Not Applicable Write Privilege Server Control Invalid Valid License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SnoopMode Table 885. The details of BIOS.MemSettings.SnoopMode attribute Description Allows tuning of memory performances under different memory bandwidths. The optimal Snoop Mode setting is highly dependent on workload type.
BIOS.MemSettings.SysMemType (Read or Write) Table 888. The details of BIOS.MemSettings.SysMemType attribute Description Indicates the current type of main memory installed in the system. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.SysMemVolt (Read or Write) Table 889. The details of BIOS.MemSettings.
Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.ErrPrompt (Read or Write) Table 892. The details of BIOS.MiscSettings.ErrPrompt attribute Description Enables or disables the F1 and F2 prompt on error. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Dependency None BIOS.MiscSettings.ReportKbdErr (Read or Write) Table 895. The details of BIOS.MiscSettings.ReportKbdErr attribute Description Enables or disables the keyboard-related error messages to be reported at system startup. Legal Values • • Default Value Not Applicable Write Privilege Server Control Report No report License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.SystemUefiShell (Read or Write) Table 896. The details of BIOS.MiscSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.SystemUefiShell (Read or Write) Table 899. The details of BIOS.MiscSettings.SystemUefiShell attribute Description Enables or disables the system UEFI shell as UEFI boot option. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.MiscSettings.
BIOS.OneTimeBoot You can manage the one time boot settings using the objects in this group. BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Table 902. The details of BIOS.OneTimeBoot.OneTimeBootMode attribute Description Configure the one time boot mode setting.
Dependency Read Only if OneTimeBootMode is set to Disabled or set to OneTimeBootSeq, OneTimeHddSeq, or OneTimeUefiBootSeq BIOS.OneTimeBoot.OneTimeHddSeqDev (Read or Write) Table 905. The details of BIOS.OneTimeBoot.OneTimeHddSeqDev attribute Description Configure the one time Hard Disk Drive (HDD) sequence for BIOS.
BIOS.ProcSettings.DataReuse (Read or Write) Table 908. The details of BIOS.ProcSettings.DataReuse attribute Description Enables or disables data reuse in cache. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.DcuIpPrefetcher (Read or Write) Table 909. The details of BIOS.ProcSettings.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.DynamicCoreAllocation (Read or Write) Table 912. The details of BIOS.ProcSettings.DynamicCoreAllocation attribute Description Enables or disables the operating system capability to set the logical processors in idle state which helps to reduce power consumption.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1Brand (Read or Write) Table 915. The details of BIOS.ProcSettings.Proc1Brand attribute Description Provides the processor brand name. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1ControlledTurbo (Read or Write) Table 916. The details of BIOS.
BIOS.ProcSettings.Proc1L2Cache (Read or Write) Table 918. The details of BIOS.ProcSettings.Proc1L2Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc1L3Cache (Read or Write) Table 919. The details of BIOS.ProcSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2ControlledTurbo (Read or Write) Table 922. The details of BIOS.ProcSettings.Proc2ControlledTurbo attribute Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance.
BIOS.ProcSettings.Proc2L2Cache (Read or Write) Table 925. The details of BIOS.ProcSettings.Proc2L2Cache attribute Description AmountBIOS.ProcSettings.Proc2L2Cache (Read Only) of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2L3Cache (Read or Write) Table 926. The details of BIOS.ProcSettings.
• • ControlledTurboLimitMinus2 ControlledTurboLimitMinus3 Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc2NumCores (Read or Write) Table 929. Details of the BIOS.ProcSettings.Proc2NumCores attribute Description Number of cores in the processor package.
BIOS.ProcSettings.Proc3L2Cache (Read or Write) Table 932. Details of the BIOS.ProcSettings.Proc3L2Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc3L3Cache (Read or Write) Table 933. Details of the BIOS.ProcSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4ControlledTurbo (Read or Write) Table 936. Details of the BIOS.ProcSettings.Proc4ControlledTurbo attribute Description Controls the turbo engagement. NOTE: You can enable this option only when System Profile is set to Performance.
BIOS.ProcSettings.Proc4L2Cache (Read or Write) Table 939. Details of the BIOS.ProcSettings.Proc4L2Cache attribute Description Amount of memory in the corresponding processor cache. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.Proc4L3Cache (Read or Write) Table 940. Details of the BIOS.ProcSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcAdjCacheLine (Read or Write) Table 943. Details of the BIOS.ProcSettings.ProcAdjCacheLine attribute Description Enables or disables the system optimization for applications that require high utilization of sequential memory access. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.ProcSettings.ProcCores (Read or Write) Table 946. Details of the BIOS.ProcSettings.ProcCores attribute Description Controls the number of enabled cores in each processor. Legal Values • • • • • • • • • • • Default Value Not Applicable Write Privilege Server Control Single All 1 2 4 6 8 10 12 14 16 License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read or Write) Table 947. Details of the BIOS.ProcSettings.
BIOS.ProcSettings.ProcExecuteDisable (Read or Write) Table 949. Details of the BIOS.ProcSettings.ProcExecuteDisable attribute Description Specifies whether Execute Disable Memory Protection Technology is enabled or disabled. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHpcMode (Read or Write) Table 950. Details of the BIOS.ProcSettings.
Legal Values • • Enabled Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcHyperTransport (Read or Write) Table 953. Details of the BIOS.ProcSettings.ProcHyperTransport attribute Description Specifies the supported HyperTransport I/O Link Specification.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.ProcX2Apic (Read or Write) Table 956. Details of the BIOS.ProcSettings.ProcX2Apic attribute Description Enables or disables the X2APIC mode. NOTE: To enable BIOS.ProcSettings.ProcX2Apic, you must enable BIOS.ProcSettings.ProcVirtualization.
BIOS.ProcSettings.RtidSetting (Read or Write) Table 959. Details of the BIOS.ProcSettings.RtidSetting attribute Description Allocates more RTIDs to the remote socket increasing cache performance between the sockets. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProxyAttributes The objects in this group manage the legacy boot protocol of LOM. BIOS.ProxyAttributes.
Legal Values • • • • Default Value Not Applicable Write Privilege Server Control Unknown None PXE iSCI License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.PxeDev1Settings The objects in this group manage the PXE device settings. BIOS.PxeDev1Settings.PxeDevnInterface (Read or Write) Table 962. Details of the BIOS.PxeDev1Settings.PxeDevnInterface attribute Description Indicates the NIC Interface used for the specified PXE device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.PxeDev1Settings.PxeDevnVlanId (Read or Write) Table 965. Details of the BIOS.PxeDev1Settings.PxeDevnVlanId attribute Description Indicates the VLAN ID for the specified PXE device. For the attribute PxeDevnVlanId, the value of n can be 1 — 4. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
BIOS.SataSettings.eSataPort1Capacity (Read or Write) Table 968. Details of the BIOS.SataSettings.eSataPort1Capacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.eSataPort1DriveType (Read or Write) Table 969. Details of the BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortACapacity (Read or Write) Table 972. Details of the BIOS.SataSettings.SataPortACapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.
BIOS.SataSettings.SataPortB (Read or Write) Table 975. Details of the BIOS.SataSettings.SataPortB attribute Description Sets the drive type of the selected device. Legal Values • • Default Value Not Applicable Write Privilege Server Control Off Auto License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortBCapacity (Read or Write) Table 976. Details of the BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortC (Read or Write) Table 979. Details of the BIOS.SataSettings.SataPortC attribute Description Sets the drive type of the selected device. Legal Values • • Default Value Not Applicable Write Privilege Server Control Off Auto License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.
BIOS.SataSettings.SataPortCModel (Read or Write) Table 982. Details of the BIOS.SataSettings.SataPortCModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortD (Read or Write) Table 983. Details of the BIOS.SataSettings.SataPortD attribute Description Sets the drive type of the selected device.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortDModel (Read or Write) Table 986. Details of the BIOS.SataSettings.SataPortDModel attribute Description Displays the drive model of the selected device. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortE (Read or Write) Table 987.
BIOS.SataSettings.SataPortEDriveType (Read or Write) Table 989. Details of the BIOS.SataSettings.SataPortEDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortEModel (Read or Write) Table 990. Details of the BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFDriveType (Read or Write) Table 993. Details of the BIOS.SataSettings.SataPortFDriveType attribute Description Indicates type of device attached to this SATA port. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortFModel (Read or Write) Table 994.
BIOS.SataSettings.SataPortGCapacity (Read or Write) Table 996. Details of the BIOS.SataSettings.SataPortGCapacity attribute Description Displays the total capacity of a hard-disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortGDriveType (Read or Write) Table 997. Details of the BIOS.SataSettings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if EmbSata is not set to AtaMode. BIOS.SataSettings.SataPortHCapacity (Read or Write) Table 1000. Details of the BIOS.SataSettings.SataPortHCapacity attribute Description Displays the total capacity of a hard disk drive. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.
BIOS.SataSettings.SataPortI (Read or Write) Table 1003. Details of BIOS.SataSettings.SataPortI attribute Description Sets the drive type of the selected device. When the Embedded SATA setting is in: • • ATA Mode, setting this attribute to Auto will enable the BIOS support for the device. Select Off to turn off the BIOS support for the device. AHCI Mode or RAID Mode, the BIOS always enables support for the device.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SataPortJ (Read or Write) Table 1007. Details of BIOS.SataSettings.SataPortJ attribute Description Sets the drive type of the selected device. When the Embedded SATA setting is in: • • ATA Mode, set this property to Auto to enable the BIOS support for the device. Select Off to turn off the BIOS support for the device. AHCI Mode or RAID Mode, the BIOS always enables support for the device.
BIOS.SataSettings.SataPortJModel (Read or Write) Table 1010. Details of BIOS.SataSettings.SataPortJModel attribute Description Displays the drive model of the selected device. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SataSettings.SecurityFreezeLock (Read or Write) Table 1011. Details of BIOS.SataSettings.
BIOS.SerialCommSettings.ExtSerialConnector (Read or Write) Table 1013. Details of BIOS.SerialCommSettings.ExtSerialConnector attribute Description Associate the External Serial Connector to Serial 1 or Serial 2 or Remote Access Device. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Serial1 Serial2 RemoteAccDevice License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.FailSafeBaud (Read or Write) Table 1014. Details of BIOS.
BIOS.SerialCommSettings.SerialComm (Read or Write) Table 1016. Details of BIOS.SerialCommSettings.SerialComm attribute Description Controls the serial communication options. Legal Values • • • • • Default Value Not Applicable Write Privilege Server Control Off OnNoConRedir OnConRedirCom1 OnConRedirCom2 OnConRedir License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SerialCommSettings.SerialPortAddress (Read or Write) Table 1017. Details of BIOS.SerialCommSettings.
License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot2 (Read or Write) Table 1019. Details of BIOS.SlotDisablement.Slot2 attribute Description Control the configuration of the card installed in slot 2. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot3 (Read or Write) Table 1020. Details of BIOS.
BIOS.SlotDisablement.Slot5 (Read or Write) Table 1022. Details of BIOS.SlotDisablement.Slot5 attribute Description Control the configuration of the card installed in slot 5. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled BootDriverDisabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SlotDisablement.Slot6 (Read or Write) Table 1023. Details of BIOS.SlotDisablement.
BIOS.SlotDisablement.Slot8 (Read or Write) Table 1025. Details of BIOS.SlotDisablement.Slot8 attribute Description Controls configuration of the card installed in this slot. You can set one of the following options for each card: • • • Enabled: The card is available during POST or to the operating system. Disabled: The card is not available during POST or to the operating system.
• Boot Driver Disabled: The Option ROM will not run during POST, the system cannot boot from the card, and the pre-boot services are not available. However, it is available to the operating system. NOTE: This option is not available if the slot contains a Dell RAID card. NOTE: If multiple cards from the same manufacturer are managed using the same boot driver, select BootDriverDisabled value for all the cards from the same manufacturer so that the Option ROM is not run.
BIOS.SysInformation.SystemCpldVersion (Read or Write) Table 1030. Details of BIOS.SysInformation.SystemCpldVersion attribute Description Displays the current revision of the system CPLD firmware. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysInformation.SystemManufacturer (Read or Write) Table 1031. Details of BIOS.SysInformation.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency` None BIOS.SysInformation.UefiComplianceVersion (Read or Write) Table 1034. Details of BIOS.SysInformation.UefiComplianceVersionattribute Description Displays the system firmware UEFI compliance level. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.EnergyPerformanceBias (Read or Write) Table 1037. Details of BIOS.SysProfileSettings.EnergyPerformanceBias attribute Description Indicates the energy performance settings.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.MemPwrMgmt (Read or Write) Table 1040. Details of BIOS.SysProfileSettings.MemPwrMgmt attribute Description Enables or disables the memory to operate in power management mode.
BIOS.SysProfileSettings.MonitorMwait (Read or Write) Table 1043. Details of BIOS.SysProfileSettings.MonitorMwait attribute Description Enables or disables Monitor or Mwait instructions. When C state is enabled in Custom mode, changing this setting does not affect system performance Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Disabled only when SysProfileSettings.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.ProcPwrPerf (Read or Write) Table 1047. Details of BIOS.SysProfileSettings.ProcPwrPerf attribute Description Sets CPU power management to maximum performance operating system DBPM or System DBPM (DAPC) mode.
License Required iDRAC Express or iDRAC Enterprise Dependency Read Only if SysProfileSettings.SysProfile is not set to Custom mode. BIOS.SysProfileSettings.SysProfile (Read or Write) Table 1050. Details of BIOS.SysProfileSettings.
BIOS.SysProfileSettings.UncoreFrequency (Read or Write) Table 1052. Details of BIOS.SysProfileSettings.UncoreFrequency attribute Description Selects the processor uncore frequency. Legal Values • • • Default Value Not Applicable Write Privilege Server Control DynamicUFS MaxUFS MinUFS License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysProfileSettings.WriteDataCrc Table 1053. Details of BIOS.SysProfileSettings.
Dependency Read Only if SysSecurity.AcPwrRcvry is set to Off. BIOS.SysSecurity.AcPwrRcvryDelay (Read or Write) Table 1055. Details of BIOS.SysSecurity.AcPwrRcvryDelay attribute Description Specifies how the system supports the staggering of power-up after AC power has been restored to the system. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Immediate User Random License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
BIOS.SysSecurity.BiosUpdateControl (Read or Write) Table 1058. Details of BIOS.SysSecurity.BiosUpdateControl attribute Description If this attribute is set to Unlocked, then all BIOS update is allowed. If set to Limited, then local BIOS updates from DOS or UEFI shell based flash utilities, or Lifecycle Controller user interface is disallowed.
BIOS.SysSecurity.PasswordStatus (Read or Write) Table 1061. Details of BIOS.SysSecurity.PasswordStatus attribute Description Locks the system password. Legal Values • • Default Value Not Applicable Write Privilege Server Control Locked Unlocked License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.PwrButton (Read or Write) Table 1062. Details of BIOS.SysSecurity.PwrButton attribute Description Enables or disables the power button on the front panel.
BIOS.SysSecurity.SetupPassword (Read or Write) Table 1064. Details of BIOS.SysSecurity.SetupPassword attribute Description Set up the system password. Optional parameter –o is used with this object to provide old password as an authentication for changing the previously configured password to the new password. The password can include the following: • • • • Up to 32 characters including whitespace. Contain numbers 0 through 9. Only lower case alphabets are accepted.
BIOS.SysSecurity.SHA256SystemPassword (Read or Write) Table 1067. Details of BIOS.SysSecurity.SHA256SystemPassword attribute Description Indicates the SHA256 hash of the system password. Legal Values String of 64 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.SysPassword (Read or Write) Table 1068. Details of BIOS.SysSecurity.SysPassword attribute Description Provides the system password.
BIOS.SysSecurity.SignedFirmwareUpdate (Read or Write) Table 1070. Details of BIOS.SysSecurity.SignedFirmwareUpdate attribute Description Enables the signed BIOS update feature. Once enabled, this attribute cannot be disabled. When you change the value from disabled to enabled, a warning message is displayed. Legal Values • • Default Value Not Applicable Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.
Legal Values • • Default Value Not Applicable Write Privilege Server Control Off On License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.SysSecurity.TpmActivation (Read or Write) Table 1074. Details of BIOS.SysSecurity.TpmActivation attribute Description Specify the operational state of the Trusted Platform Module (TPM).
Dependency None BIOS.SysSecurity.TpmPpiBypassClear Table 1077. Details of BIOS.SysSecurity.TpmPpiBypassClear attribute Description Clears the Physical Presence Interface (PPI) Advanced Configuration and Power Interface (ACPI) and enables the operating system to by-pass the PPI-related prompts. Legal Values • • Default Value NA Write Privilege Server control Enabled Disabled License Required RACADM Dependency None BIOS.SysSecurity.TpmPpiBypassProvision Table 1078. Details of BIOS.SysSecurity.
BIOS.SysSecurity.TPMStatus (Read Only) Table 1080. Details of BIOS.SysSecurity.TPMStatus attribute Description Displays the status of TPM. Legal Values String of up to 64 ASCII characters. Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.UefiBootSettings The objects in this group manages the UEFI boot settings. BIOS.UefiBootSettings.UefiBootSeq (Read or Write) Table 1081. Details of BIOS.UefiBootSettings.
FC.FCDevice.BusDeviceFunction (Read Only) Table 1083. Details of FC.FCDevice.BusDeviceFunction attribute Description Indicates the enumerated PCI Bus, Device, and Function value as a single string. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCDevice.ChipMdl (Read Only) Table 1084. Details of FC.FCDevice.
FC.FCDevice.PCIDeviceID (Read Only) Table 1087. Details of FC.FCDevice.PCIDeviceID attribute Description Indicates the device ID present in the PCI configuration space. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget The objects in this group manage the Fibre Channel target. FC.FCTarget.BootScanSelection (Read or Write) Table 1088. Details of FC.FCTarget.
FC.FCTarget.FirstFCTargetWWPN (Read or Write) Table 1090. Details of FC.FCTarget.FirstFCTargetWWPN attribute Description Specifies the World Wide Port Name of the first Fibre Channel boot target. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.FCTarget.SecondFCTargetLUN (Read or Write) Table 1091. Details of FC.FCTarget.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginTimeout (Read or Write) Table 1094. Details of FC.HBAConfig.FabricLoginTimeout attribute Description Sets the SAN Fabric login time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.FabricLoginRetryCount (Read or Write) Table 1095. Details of FC.HBAConfig.
Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.HardZoneAddress (Read or Write) Table 1098. Details of FC.HBAConfig.HardZoneAddress attribute Description Sets the Hard Zone address. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.
Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.PortDownTimeout (Read or Write) Table 1102. Details of FC.HBAConfig.PortDownTimeout attribute Description Sets the target port down time out. Legal Values Not Applicable Default Value 3000 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.HBAConfig.
FC.PortConfig.DeviceName (Read Only) Table 1105. Details of FC.PortConfig.DeviceName attribute Description Indicates the product name of the Fibre Channel host bus adapter. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.FCDevice (Read Only) Table 1106. Details of FC.PortConfig.FCDevice attribute Description Displays the version of the device and firmware.
FC.PortConfig.PortNumber (Read Only) Table 1109. Details of FC.PortConfig.PortNumber attribute Description Indicates the Fibre Channel Host Bus Adapter port number. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.PortSpeed (Read or Write) Table 1110. Details of FC.PortConfig.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.WWN (Read Only) Table 1113. Details of FC.PortConfig.WWN attribute Description Indicates the permanent Fibre Channel World Wide Node name. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable FC.PortConfig.WWPN (Read Only) Table 1114. Details of FC.PortConfig.
NIC.ConfigureFormn.MacAddr (Read Only) Table 1116. Details of NIC.ConfigureFormn.MacAddr attribute Description Indicates the permanent MAC address. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.FIPMacAddr (Read Only) Table 1117. Details of NIC.ConfigureFormn.FIPMacAddr attribute Description Indicates the permanent FIP-MAC address for FCoE.
NIC.ConfigureFormn.FCoEOffloadMode (Read or Write) Table 1120. Details of NIC.ConfigureFormn.FCoEOffloadMode attribute Description Enables or disables the FCoE on the partition. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.NicMode (Read or Write) Table 1121. Details of NIC.ConfigureFormn.
NIC.ConfigureFormn.WWPN (Read Only) Table 1124. Details of NIC.ConfigureFormn.WWPN attribute Description Indicates the Fibre Channel World Wide Port Name identifier for FCoE. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.VirtWWN (Read or Write) Table 1125. Details of NIC.ConfigureFormn.
NIC.ConfigureFormn.VirtIscsiMacAddr (Read or Write) Table 1128. Details of NIC.ConfigureFormn.VirtIscsiMacAddr attribute Description Assigns the MAC address for partition iSCSI off load. Legal Values Not Applicable Default Value 00:00:00:00:00:00 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.ConfigureFormn.VirtFIPMacAddr (Read or Write) Table 1129. Details of NIC.ConfigureFormn.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DCBSettings.DCBExchangeProtocol (Read Only) Table 1132. Details of NIC.DCBSettings.DCBExchangeProtocol attribute Description Indicates whether Data Center Bridging (DCB) Exchange Protocol capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.DCBSettings.
NIC.DeviceLevelConfig To manage the device level configurations, use the objects in this group. NOTE: To get the actual supported values for BIOS, NIC, and FC components, query the help with an index. If you query without an index, the generic help is displayed. NIC.DeviceLevelConfig.EVBModesSupport (Read Only) Table 1135. Details of NIC.DeviceLevelConfig.EVBModesSupport attribute Description Indicates the type of EVB Modes supported.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.DeviceLevelConfig.SRIOVSupport (Read Only) Table 1138. Details of NIC.DeviceLevelConfig.SRIOVSupport attribute Description Indicates whether SR-IOV capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency` None NIC.DeviceLevelConfig.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxFrameSize (Read Only) Table 1141. Details of NIC.FCOECapabilities.MaxFrameSize attribute Description Indicates the maximum frame size for each FCoE frame. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxIOsPerSession (Read Only) Table 1142. NIC.
Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.MaxNumberLogins (Read Only) Table 1145. NIC.FCOECapabilities.MaxNumberLogins Description Indicates the maximum number of logins supported per port. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCOECapabilities.
Dependency None NIC.FCOECapabilities.MTUReconfigurationSupport (Read Only) Table 1148. NIC.FCOECapabilities.MTUReconfigurationSupport Description Indicates whether the MTU reconfiguration capability is supported. Legal Values • • Default Value Not Applicable Write Privilege Not Applicable Available Unavailable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEConfiguration The following section provides information about the objects in the NIC.FCoEConfiguration group.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.BootOrderFourthFCoETarget (Read or Write) Table 1151. NIC.FCoEConfiguration.BootOrderFourthFCoETarget Description Specifies the port's fourth defined target in the FCoE boot. Legal Values Not Applicable Default Value 0 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.FCoEConfiguration.
NIC.FCoEConfiguration.FirstFCoEBootTargetLUN (Read or Write) Table 1154. NIC.FCoEConfiguration.FirstFCoEBootTargetLUN Description LUN of the first FCoE storage target that the FCoE initiator will start the system from when Connect attribute is enabled. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Enable FCoEConfiguration.ConnectFirstFCoETarget NIC.FCoEConfiguration.
NIC.FCoEConfiguration.MTUParams (Read or Write) Table 1157. NIC.FCoEConfiguration.MTUParams Description Configure the MTU setting. Legal Values • • • Default Value Not Applicable Write Privilege Server Control Global Per DCB Priority Per VLAN License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams The following section provides information about the objects in the NIC.FCoEGenParams group. NIC.FCoEGenParams.FCoEBootScanSelection (Read or Write) Table 1158. NIC.
Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoEFirstHddTarget (Read or Write) Table 1160. NIC.FCoEGenParams.FCoEFirstHddTarget Description Specifies whether the FCoE target is represented as the first HDD to the system. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Table 1163. NIC.FCoEGenParams.FCoETgtBoot Description Enables the FCoE initiator to start system to the FCoE target. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.FrmwImgMenu The following section provides information about the objects in the NIC.FrmwImgMenu group. NIC.
NIC.FrmwImgMenu.FamilyVersion (Read Only) Table 1166. NIC.FrmwImgMenu.FamilyVersion Description Indicates the firmware family version information. Legal Values String of up to 8 ASCII characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.GlobalBandwidthAllocation The following section provides information about the objects in the NIC.GlobalBandwidthAllocation group. NIC.GlobalBandwidthAllocation.
NIC.IscsiFirstTgtParams The following section provides information about the objects in the NIC.IscsiFirstTgtParams group. NIC.IscsiFirstTgtParams.AddressingMode (Read or Write) Table 1169. NIC.IscsiFirstTgtParams.AddressingMode Description Enables or disables the connection to the first iSCSI target. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiFirstTgtParams.
NIC.IscsiFirstTgtParams.FirstTgtChapId (Read or Write) Table 1172. NIC.IscsiFirstTgtParams.FirstTgtChapId Description Set the first iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) ID. Legal Values String of up to 128 ASCII characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiFirstTgtParams.
• IPv6 Default Value IPv4 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiFirstTgtParams.FirstTgtIscsiName (Read or Write) Table 1176. NIC.IscsiFirstTgtParams.FirstTgtIscsiName Description Set the iSCSI Qualified Name (IQN) of the first iSCSI storage target.
Default Value Disabled Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiGenParams.ChapMutualAuth (Read or Write) Table 1179. NIC.IscsiGenParams.ChapMutualAuth Description Enables or disables mutual CHAP authentication between the iSCSI initiator and target.
NIC.IscsiGenParams.IpAutoConfig (Read or Write) Table 1182. NIC.IscsiGenParams.IpAutoConfig Description Controls the source of the initiator IP address DHCP or static assignment. This option is specific to IPv6. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if IscsiGenParams.IpVer is set to 'IPv4' and VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.
NIC.IscsiGenParams.IscsiViaDHCP (Read or Write) Table 1185. NIC.IscsiGenParams.IscsiViaDHCP Description Enables the acquisition of iSCSI target parameters from DHCP. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.IscsiVLanId (Read or Write) Table 1186. NIC.IscsiGenParams.
License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiGenParams.LunBusyRetryCnt (Read or Write) Table 1189. NIC.IscsiGenParams.LunBusyRetryCnt Description Specifies the number of connection attempts the iSCSI boot initiator will attempt if the iSCSI target LUN is busy.
NIC.IscsiGenParams.WinHbaBootMode (Read or Write) Table 1192. NIC.IscsiGenParams.WinHbaBootMode Description When enabled, it enables iSCSI Offload HBA start mode and disables iSCSI software initiator boot. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.IscsiInitiatorParams The following section provides information about the objects in the NIC.IscsiInitiatorParams group. NIC.
NIC.IscsiInitiatorParams.IscsiInitiatorGateway (Read or Write) Table 1195. NIC.IscsiInitiatorParams.IscsiInitiatorGateway Description Specifies the Default Gateway of the iSCSI initiator. Legal Values String of 2-39 characters (Ipv4 or Ipv6 gateway) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Available if VndrConfigGroup.iSCSIBootSupport is Unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write) Table 1198. NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns Description Specifies the Primary DNS IP address of the iSCSI initiator. Legal Values String of 2–39 characters (IPv4 or IPv6 gateway) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiInitiatorParams.
NIC.IscsiInitiatorParams.IscsiInitiatorSubnetPrefix (Read or Write) Table 1201. Details of NIC.IscsiInitiatorParams.IscsiInitiatorSubnetPrefix attribute Description Specifies the IPv6 Subnet Mask Prefix of the iSCSI initiator. Legal Values String of 2–39 characters (IPv6 Subnet) Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
NIC.IscsiSecondaryDeviceParams.UseIndTgtPortal (Read or Write) Table 1204. NIC.IscsiSecondaryDeviceParams.UseIndTgtPortal Description Specifies whether to use Independent Target Portal when multipath I/O is enabled. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.
Dependency Not available if VndrConfigGroup.iSCSIBootSupport is unavailable. NIC.IscsiSecondTgtParams.SecondTgtChapId (Read or Write) Table 1207. NIC.IscsiSecondTgtParams.SecondTgtChapId Description Specifies the second iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) ID Legal Values Values: 0–128. Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not available if VndrConfigGroup.
NIC.IscsiSecondTgtParams.SecondTgtIpVer (Read or Write) Table 1210. NIC.IscsiSecondTgtParams.SecondTgtIpVer Description Specifies whether or not IPv4 or IPv4 network address is used for the second iSCSI target. Legal Values • • Default Value IPv4 Write Privilege Server Control IPv4 IPv6 License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.IscsiSecondTgtParams.SecondTgtIscsiName (Read or Write) Table 1211. NIC.IscsiSecondTgtParams.
NIC.NICConfig.BannerMessageTimeout (Read or Write) Table 1213. NIC.NICConfig.BannerMessageTimeout Description Specifies the number of seconds that the OptionROM banner is displayed during POST. Legal Values Not Applicable Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.BootOptionROM (Read or Write) Table 1214. NIC.NICConfig.
Legal Values • • • • Default Value AutoDetect Write Privilege Server Control AutoDetect BBS Int18h Int19h License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.NICConfig.HideSetupPrompt (Read or Write) Table 1217. NIC.NICConfig.HideSetupPrompt Description Enables or disables the option ROM setup prompt during Power On Self Test (POST).
• • • 10 Mbps Full 100 Mbps Half 100 Mbps Full Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICConfig.NumberVFAdvertised (Read or Write) Table 1220. NIC.NICConfig.NumberVFAdvertised Description Indicates the number of PCI Virtual Functions advertised on the port when SR-IOV is enabled.
NIC.NICPartitioningConfig To configure the NICPartitioning properties, use the objects in this group. NIC.NICPartitioningConfig.NicPartitioning (Read or Write) Table 1223. NIC.NICPartitioningConfig.NicPartitioning Description Enables or disables NIC partitioning for all device ports. Legal Values • • Default Value Disabled Write Privilege Server Control Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICPartitioningConfig.
NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled (Read Only) Table 1226. NIC.NICPartitioningConfig.NumberPCIEFunctionsEnabled Description Indicates the number of physical PCIe functions currently enabled on this port. Legal Values Values: 1–65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.NICPartitioningConfig.NumberPCIEFunctionsSupport ed (Read Only) Table 1227. Details of NIC.NICPartitioningConfig.
NIC.VndrConfigGroup.BlnkLeds (Read or Write) Table 1229. NIC.VndrConfigGroup.BlnkLeds Description Identifies the physical network port by blinking the associated LED. Legal Values Values: 0–15 Default Value 15 Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.ChipMdl (Read Only) Table 1230. NIC.VndrConfigGroup.ChipMdl Description Indicates the chip type or revision.
Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.DeviceName (Read Only) Table 1233. NIC.VndrConfigGroup.DeviceName Description Official product name of the device. Legal Values Not Applicable Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency Not Applicable NIC.VndrConfigGroup.FCoEBootSupport (Read Only) Table 1234. NIC.VndrConfigGroup.
NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only) Table 1236. NIC.VndrConfigGroup.FCoEOffloadSupport Description Indicates whether FCoE Offload capability is supported. Legal Values None Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only) Table 1237. NIC.VndrConfigGroup.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.iSCSIBootSupport (Read Only) Table 1240. NIC.VndrConfigGroup.iSCSIBootSupport Description Indicates whether iSCSI Boot capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.ISCSIMacAddr (Read Only) Table 1241. NIC.VndrConfigGroup.
Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.LinkStatus (Read Only) Table 1244. NIC.VndrConfigGroup.LinkStatus Description Indicates the physical network link status that reports the controller. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
NIC.VndrConfigGroup.NicPartitioningSupport (Read Only) Table 1247. NIC.VndrConfigGroup.NicPartitioningSupport Description Indicates whether NIC Partitioning capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.NWManagementPassThrough (Read Only) Table 1248. NIC.VndrConfigGroup.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.PCIDeviceID (Read Only) Table 1251. NIC.VndrConfigGroup.PCIDeviceID Description Indicates the PCI Device ID of the port. Legal Values String of up to 4 characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.PXEBootSupport (Read Only) Table 1252.
NIC.VndrConfigGroup.RXFlowControl (Read Only) Table 1254. NIC.VndrConfigGroup.RXFlowControl Description Indicates whether Receive (RX) Flow control capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TOESupport (Read Only) Table 1255. NIC.VndrConfigGroup.TOESupport Description Indicates whether TCP/IP Offload Engine capability is supported.
Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.TXFlowControl (Read Only) Table 1258. NIC.VndrConfigGroup.TXFlowControl Description Indicates whether Transmit (TX) Flow Control capability is supported. Legal Values None Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.
NIC.VndrConfigGroup.VirtMacAddr (Read or Write) Table 1261. NIC.VndrConfigGroup.VirtMacAddr Description Programmatically assignable MAC address. Programmatic write for support of I/O Identity feature. Legal Values String of up to 17 characters Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.VirtualLinkControl (Read or Write) Table 1262. NIC.VndrConfigGroup.
License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.WWN (Read Only) Table 1265. NIC.VndrConfigGroup.WWN Description Fibre Channel World Wide Node Name identifier for FCoE. Legal Values String of up to 23 characters Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None NIC.VndrConfigGroup.WWPN (Read Only) Table 1266. NIC.VndrConfigGroup.
Storage.Controller.BatteryLearnMode (Read Only) Table 1268. Storage.Controller.BatteryLearnMode Description Battery Learn Mode controls a RAID controller's Battery Learn Cycle. Legal Values • • • • Default value None Write Privilege Not Applicable Automatic Warn Disabled Not Supported License Required iDRAC Express or iDRAC Enterprise Dependency A battery must be present on the controller. Storage.Controller.CheckConsistencyMode (Read or Write) Table 1269. Storage.Controller.
• Headless Safe Mode Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.CopybackMode (Read or Write) Table 1272. Storage.Controller.CopybackMode Description This attribute represents the mode of restoring the configuration of a virtual disk when a failed physical disk drive is replaced in an array.
License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.PatrolReadMode (Read or Write) Table 1275. Storage.Controller.PatrolReadMode Description Patrol Read is a feature for identifying disk errors to avoid disk failures and data loss or corruption. The Patrol Read only runs on the disks that are used in a virtual disk or that are hot-spare.
Legal Values • • Default Value Disabled Write Privilege Configure iDRAC Enabled Disabled License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.PossibleloadBalancedMode (Read or Write) Table 1279. Storage.Controller.PossibleloadBalancedMode Description This attribute represents the ability to automatically use both controller ports connected to the same enclosure to route I/O requests.
Storage.Controller.RequestedControllerMode (Read Only) Table 1282. Storage.Controller.RequestedControllerMode Description Indicates the requested personality mode of the controller. PERC 9 controller supports RAID and HBA and PERC 10 controller supports RAID and Enhanced HBA. Legal Values • • • RAID HBA Enhanced HBA NOTE: HBA or Enhanced HBA support is dependent on the type of PERC controller. Default value RAID License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.
Storage.Controller.SupportRAID10UnevenSpans (Read Only) Table 1285. Storage.Controller.SupportRAID10UnevenSpans Description This is a read-only attribute. This property indicates if this controller supports uneven spans for RAID 10. Legal Values • • Supported Not Supported Default value Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.Controller.T10PICapability (Read Only) Table 1286. Storage.Controller.
Legal Values string of 0 to 10 characters Default Value Not Applicable License Required RACADM Dependency None Storage.enclosure.BackplaneCurrentMode (Read Only) Table 1289. Storage.enclosure.BackplaneCurrentMode (Read Only) Description Displays the current mode of the backplane. Legal Values storage.enclosure.
Legal Values The values are dynamic, it depends on the platform. Default Value Not Applicable Write Privilege Not Applicable License Required RACADM Dependency None Storage.PhysicalDisk The objects in this group manage storage physical disk drive attributes. This group is indexed. The following section provides information about the objects in this group. Storage.PhysicalDisk.BlockSizeInBytes (Read Only) Table 1293. Storage.PhysicalDisk.
License Required iDRAC Express or iDRAC Enterprise Dependency None Storage.PhysicalDisk.RaidType Table 1296. Storage.PhysicalDisk.RaidType Description Indicates the metadata type on the disk. Legal Values • • • • Default Value Not Applicable None Software RAID Windows Software RAID Hardware RAID License Required RACADM Dependency None Storage.PhysicalDisk.T10PICapability (Read Only) Table 1297. Storage.PhysicalDisk.T10PICapability Description This is a read-only attribute.
Storage.VirtualDisk.DiskCachePolicy (Read or Write) Table 1299. Storage.VirtualDisk.DiskCachePolicy Description Set the physical disk drive caching policy of all members of a Virtual Disk by enabling the Disk Cache Policy. When this feature is enabled, the physical disk drive writes data to the physical disk drive cache before writing it to the physical disk drive. Because it is faster to write data to the cache than to a disk, enabling this feature can improve system performance.
Storage.VirtualDisk.WritePolicy (Read or Write) Table 1302. Details of Storage.VirtualDisk.WritePolicy Description The write policies specify whether or not the controller sends a write-request completion signal as soon as the data is in the cache or after it has been written to disk. NOTE: Storage.VirtualDisk.WritePolicy attribute is read-only for few PERCs—for example, H330.
5 New Groups and Objects for 14th generation of PowerEdge servers Table 1303. New groups and new objects added for 14G Groups Objects iDRAC.GroupManager iDRAC.GroupManager.GlobalState(Read or Write) iDRAC.GroupManager.GroupName(Read) iDRAC.GroupManager.GroupUID(Read) iDRAC.GUI iDRAC.GUI.SecurityPolicyMessage iDRAC.Security iDRAC.Security.FIPSMode (Read or Write) iDRAC.SerialRedirection iDRAC.SerialRedirection.QuitKey (Read or Write) iDRAC.ServerBoot iDRAC.ServerBoot.
Groups Objects System.pcieSlotLFM. CardType (Read) System.pcieSlotLFM. CustomLFM (Read or Write) System.pcieSlotLFM .LFMMode(Read or Write) System.pcieSlotLFM.MaxLFM (Read) System.pcieSlotLFM.Slot (Read) System.pcieSlotLFM.SlotState (Read) System.pcieSlotLFM.TargetLFM System.pcieSlotLFM. CardType (Read) System.pcieSlotLFM. CustomLFM (Read or Write) System.pcieSlotLFM .LFMMode(Read or Write) System.pcieSlotLFM.MaxLFM (Read) System.pcieSlotLFM.Slot (Read) System.pcieSlotLFM.SlotState (Read) System.
6 Legacy and New Groups and Objects Table 1304. Legacy and New Groups and Objects Legacy Groups and Objects New Groups and Objects idRacInfo iDRAC.Info idRacType Type idRacProductInfo Product idRacDescriptionInfo Description idRacVersionInfo Version idRacBuildInfo Build idRacName Name cfgActiveDirectory iDRAC.
Legacy Groups and Objects New Groups and Objects cfgLanNetworking iDRAC.Nic cfgNicEnable Enable cfgNicMacAddress MACAddress cfgDNSRacName DNSRacName cfgNicSelection Selection cfgNicFailoverNetwork Failover cfgDNSDomainName DNSDomainName cfgDNSDomainNameFromDHCP DNSRacName cfgDNSRegisterRac DNSRegister cfgNicVLanEnable VLanEnable cfgNicVLanID VLanID cfgNicVLanPriority VLanPriority iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIPv6Address5 Address5 cfgIPv6Address6 Address6 cfgIPv6Address7 Address7 cfgIPv6Address8 Address8 cfgIPv6Address9 Address9 cfgIPv6Address10 Address10 cfgIPv6Address11 Address11 cfgIPv6Address12 Address12 cfgIPv6Address13 Address13 cfgIPv6Address14 Address14 cfgIPv6Address15 Address15 cfgIPv6DNSServersFromDHCP6 DNSFromDHCP6 cfgIPv6DNSServer1 DNS1 cfgIPv6DNSServer2 DNS2 cfgServerPower System.
Legacy Groups and Objects New Groups and Objects cfgServerPowerLastHourMaxPower Max.LastHour cfgServerPowerLastHourMaxTime Max.LastHour.Timestamp cfgServerPowerLastDayMinPower Min.LastDay cfgServerPowerLastDayMinTime Min.LastDay.Timestamp cfgServerPowerLastDayMaxPower Max.LastDay cfgServerPowerLastDayMaxTime Max.LastDay.Timestamp cfgServerPowerLastWeekMinPower Min.LastWeek cfgServerPowerLastWeekMinTime Min.LastWeek.Timestamp cfgServerPowerLastWeekMaxPower Max.
Legacy Groups and Objects New Groups and Objects cfgUserAdminUserName UserName cfgUserAdminPassword Password cfgUserAdminEnable Enable cfgUserAdminPrivilege Privilege cfgUserAdminIpmiLanPrivilege IpmiLanPrivilege cfgUserAdminIpmiSerialPrivilege IpmiSerialPrivilege cfgUserAdminSolEnable SolEnable cfgRemoteHosts iDRAC.SysLog cfgRhostsSyslogEnable SysLogEnable cfgRhostsSyslogServer1 Server1 cfgRhostsSyslogServer2 Server2 cfgRhostsSyslogServer3 Server3 cfgRhostsSyslogPort Port iDRAC.
Legacy Groups and Objects New Groups and Objects Port Timeout cfgSsnMgtRacadmTimeout iDRAC.Racadm Enable Timeout cfgSsnMgtConsRedirMaxSessions iDRAC.VirtualConsole EncryptEnable Enable PluginType LocalVideo Port MaxSessions Timeout AccessPrivilege cfgSsnMgtWebserverTimeout iDRAC.Webserver Enable HttpPort Timeout HttpsPort LowerEncryptionBitLength [cfgSerial] iDRAC.
Legacy Groups and Objects New Groups and Objects cfgSerialTelnetEnable iDRAC.Telnet cfgSerialSshEnable iDRAC.SSH [cfgOobSnmp] iDRAC.SNMP cfgOobSnmpAgentEnable AgentEnable cfgOobSnmpAgentCommunity AgentCommunity [cfgNetTuning] cfgNetTuningNic100MB iDRAC.Nic cfgNetTuningNicFullDuplex iDRAC.Nic cfgNetTuningNicMtu iDRAC.Nic cfgNetTuningNicAutoneg iDRAC.Nic [cfgRacTuning] cfgRacTuneRemoteRacadmEnable=1 iDRAC.Racadm cfgRacTuneWebserverEnable=1 iDRAC.Webserver cfgRacTuneHttpPort=80 iDRAC.
Legacy Groups and Objects New Groups and Objects cfgRacTuneCtrlEConfigDisable=0 PrebootConfig cfgRacTuneLocalConfigDisable=0 LocalConfig cfgRacTuneVirtualConsoleAuthorizeMultipleSessions=0 iDRAC.VirtualConsole ifcRacManagedNodeOs System.ServerOS ifcRacMnOsHostname HostName ifcRacMnOsOsName OSName cfgRacSecurity iDRAC.
Legacy Groups and Objects New Groups and Objects cfgLdapRoleGroup iDRAC.LDApRole cfgLdapRoleGroupIndex NA cfgLdapRoleGroupDN DN cfgLdapRoleGroupPrivilege Privilege cfgStandardSchema iDRAC.ADGroup cfgSSADRoleGroupIndex NA cfgSSADRoleGroupName Name cfgSSADRoleGroupDomain Domain cfgSSADRoleGroupPrivilege Privilege cfgIpmiSerial iDRAC.
Legacy Groups and Objects New Groups and Objects cfgIpmiPetCommunityName CommunityName cfgUserDomain iDRAC.UserDomain cfgUserDomainIndex NA cfgUserDomainName Name cfgSmartCard iDRAC.SmartCard cfgSmartCardLogonEnable SmartCardLogonEnable cfgSmartCardCRLEnable SmartCardCRLEnable [cfgIPv6URL] cfgIPv6URLString NA cfgVFlashSD iDRAC.
Legacy Groups and Objects New Groups and Objects iDRAC.SNMP.Alert cfgIpmiPetAlertEnable Enable cfgIpmiPetAlertDestIpAddr DestAddr Topics: • cfgSSADRoleGroupPrivilege (Read or Write) cfgSSADRoleGroupPrivilege (Read or Write) Table 1305. cfgSSADRoleGroupPrivilege Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.
7 Deprecated and New Subcommands Table 1307.