Owners Manual

Installing the cooling shroud retention bar
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that came with the product.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. Keep the #1 and #2 Phillips screwdrivers ready.
4. Remove the cooling shroud retention bar.
NOTE: You must remove the cooling shroud retention bar to replace a faulty retention bar or service other components
inside the system.
5. Ensure that the memory module socket ejectors are in the locked position.
Steps
1. Lower the cooling shroud retention bar into the system until the screw holes on the cooling shroud retention bar align with
the screw holes on the chassis.
2. Install the screws to secure the cooling shroud retention bar to the system.
Figure 12. Installing the cooling shroud retention bar
a. screw (9)
b. cooling shroud retention bar
c. standoff (2)
Next steps
1. Install the cooling shroud.
2. Follow the procedure listed in the After working inside your system section.
Related references
Instrucciones de seguridad on page 50