Owners Manual

Table Of Contents
Compute
sleds
Specifications
Up to four PowerEdge FC430 compute sleds mixed with up to two PowerEdge FC630/FC640 compute
sleds, or
One PowerEdge FC830 compute sled mixed with up to two PowerEdge FC630/FC640 compute sleds
Storage sleds Specifications
PowerEdge FX2s
Up to three PowerEdge FD332 storage sleds mapped to one PowerEdge FC630/FC640 compute sled, or
Up to two PowerEdge FD332 storage sleds mapped to two PowerEdge FC630/FC640 compute sleds, or
Up to two PowerEdge FD332 storage sleds mapped to up to four PowerEdge FC430 compute sleds, or
Up to two PowerEdge FD332 storage sleds mapped to one PowerEdge FC830 compute sled
NOTE: For more information on the technical specifications for the compute and storage sled(s), see the relevant sled
Owner's Manual at Dell.com/poweredgemanuals.
NOTE: For information on mapping of storage sleds to compute sleds in the PowerEdge FX2s enclosure, see the Dell
PowerEdge FD332 Owner's Manual at Dell.com/poweredgemanuals.
Power specifications
Power supply
unit
Specifications
Wattage 1100 W (1050 W for low line)
1600 W (800 W for low line)
2000 W (1000 W for low line)
2400 W (1400 W for low line)
Connector Card Edge
Heat dissipation 394 BTU/hr (full load for the power supply unit only) (1100 W power supply unit)
475 BTU/hr (full load for the power supply unit only) (1600 W power supply unit)
635 BTU/hr (full load for the power supply unit only) (2000 W power supply unit)
760 BTU/hr (full load for the power supply unit only) (2400 W power supply unit)
Maximum inrush
current
25 A
System voltage
requirements
100 240 V AC
NOTE: This system is also designed to be connected to IT power systems with a phase to phase
voltage not exceeding 230 V.
Chassis Management Controller (CMC) specifications
Externally
accessible
connectors
Specifications
Remote
management
Two dedicated 10/100/1000 Mb RJ-45 (for integrated Ethernet remote access controller). Gb port
connects to the CMC modules external management network. STK port allows CMCs in adjacent
enclosures to be daisy chained. The STK port can also be used for CMC NIC failover.
Serial 9-pin, DTE, 16550-compatible
86 Technical specificationsPowerEdge FX2/FX2s