Owners Manual

Initial system configuration
Topics:
Before you begin
Setting up your PowerEdge FX2/FX2s
Logging in to the CMC
Before you begin
CAUTION: The enclosure power supplies must be connected to a PDU or to an electrical outlet. The power
supplies require a 100 V to 120 V or 200 V to 240 V power source. You can select only one AC power input, as the
system does not operate at both ranges simultaneously.
If applicable, update all PCIe card firmware and iDRAC firmware on the compute sled(s).
Download the latest version of CMC firmware from Dell.com/support. Also, make sure that you have the Dell Systems
Management Tools and Documentation DVD that was included with your system.
If your network uses static addressing, you need the IP address, subnet mask, and gateway to configure the CMC and other
sleds in the enclosure.
Setting up your PowerEdge FX2/FX2s
Steps
1. Unpack the enclosure and sled(s), and identify each item.
For more information, see the Dell PowerEdge FX2 Getting Started With Your System and Rack Installation Guide at
Dell.com/poweredgemanuals.
NOTE:
Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system
by yourself.
CAUTION: To reduce chassis weight while installing the enclosure in the rack, remove the power supply units
(PSUs) and sleds before lifting the enclosure. Note the number of each sled and temporarily label them
before removal, so that you can replace them in their original locations.
2. Install the enclosure in the rack.
3. Install the sled(s) and PSUs.
CAUTION: Do not turn on the compute sled(s) until you have configured the I/O module.
4. Connect the network cable to the I/O modules to provide network connection to the compute sleds.
5. Connect the PSUs to a power distribution unit (PDU) or electrical outlet by using the power cables.
6. Optionally, connect the video and keyboard/mouse to the enclosure.
7. Press the power button on the enclosure front panel to turn on the enclosure.
8. Configure the Chassis Management Controller (CMC) by using the CMC web interface and the RACADM command line
interface (CLI).
NOTE:
For a detailed description on configuring the CMC settings, see the PowerEdge FX2/FX2s CMC Users Guide at
Dell.com/esmmanuals.
9. Perform either of the following tasks to obtain a CMC IP address by using DHCP:
Connect a serial cable to the serial DB9 connector on the CMC module. Log in by using the default credentials and use
RACADM commands to retrieve the CMC IP address.
2
20 Initial system configuration