Reference Guide

216 | Stacking
www.dell.com | support.dell.com
Figure 17-26. show redundancy Command Example
FTOS#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active Indicates master unit
Stack-unit SW Version: E8-3-17-46
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby Indicates standby unit
Peer stack-unit ID: 1
Stack-unit SW Version: E8-3-17-46
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover Failover type with redundancy
Auto reboot Stack-unit: Enabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: succeeded Sep 03 1993 09:36:52
Start-up Config: succeeded Sep 03 1993 09:36:52 Last synch of startup configuration
Runtime Event Log: succeeded Sep 03 1993 09:36:52
Running Config: succeeded Sep 03 1993 09:36:52
ACL Mgr: succeeded Sep 03 1993 09:36:52
LACP: no block sync done
STP: no block sync done
SPAN: no block sync done