All interfaces on the Aggregator are operationally down
Symptom: All Aggregator interfaces are down.
Resolution: Ensure that port channel 128 is up and that the Aggregator-facing port channel on the
top-of-rack switch is correctly configured.
Steps to Take:
1. Verify that uplink port-channel 128 i s up (
show interfaces port-channel 128 brief command) and
display the status of member ports (
show uplink-state-group 1 detail command).
2. Verify that the downstream port channel in the top-of-rack switch that connects to the Aggregator is
configured correctly.
FTOS#show interfaces port-channel 128 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 128 L2L3 up 17:36:24 Te 0/33 (Up)
Te 0/35 (Up)
Te 0/36 (Up)
Te 0/39 (Up)
Te 0/51 (Up)
Te 0/53 (Up)
Te 0/54 (Up)
Te 0/56 (Up)
FTOS#show uplink-state-group 1 detail
(Up): Interface up (Dwn): Interface down (Dis): Interface disabled
Uplink State Group : 1 Status: Enabled, Up
Defer Timer : 10 sec
Upstream Interfaces : Po 128(Up)
Downstream Interfaces : Te 0/1(Up) Te 0/2(Up) Te 0/3(Dwn) Te 0/4(Dwn) Te 0/5(Up)
Te 0/6(Dwn) Te 0/7(Dwn) Te 0/8(Up) Te 0/9(Up) Te 0/10(Up)
Te 0/11(Dwn) Te 0/12(Dwn) Te 0/13(Up) Te 0/14(Dwn) Te 0/15(Up)
Te 0/16(Up) Te 0/17(Dwn) Te 0/18(Dwn) Te 0/19(Dwn) Te 0/20(Dwn)
Te 0/21(Dwn) Te 0/22(Dwn) Te 0/23(Dwn) Te 0/24(Dwn) Te 0/25(Dwn)
Te 0/26(Dwn) Te 0/27(Dwn) Te 0/28(Dwn) Te 0/29(Dwn) Te 0/30(Dwn)