Concept Guide

Dell 8/4Gbps FC SAN Module Administrator’s Guide 49
53-1001345-01
firmwareShow
B
Slot 8 (FR4-18i): Firmware has been downloaded successfully. Blade is
rebooting with the new firmware.
[9]: Mon Dec 19 18:50:12 2007
Slot 8 (FR4-18i): Firmware commit has started on the blade. This may take up to
10 minutes.
[10]: Mon Dec 19 18:50:51 2007
Slot 8 (FR4-18i): The commit operation has completed successfully.
[11]: Mon Dec 19 18:55:39 2007
Slot 5 (CP0, active): Firmware has been downloaded successfully on Standby CP.
[12]: Mon Dec 19 18:55:46 2007
Slot 5 (CP0, active): Standby CP reboots.
[13]: Mon Dec 19 18:57:06 2007
Slot 5 (CP0, active): Standby CP booted successfully with new firmware.
[14]: Mon Dec 19 18:57:10 2007
Slot 5 (CP0, active): Firmware commit operation has started on both active and
standby CPs.
[15]: Mon Dec 19 19:01:38 2007
Slot 5 (CP0, active): Firmware commit operation has completed successfully on
active CP.
[16]: Mon Dec 19 19:01:39 2007
Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use
firmwareshow to verify the firmware versions.
firmwareShow
Displays the OS versions on all firmware partitions in the system.
Synopsis firmwareshow
Description Use this command to display the OS, SAS, and SA firmware versions. The command shows the
firmware versions on both the primary and secondary partitions of the storage device.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to “Understanding Virtual Fabric restrictions” on page 32 and “Understanding
Admin Domain restrictions” on page 33 for details.
Operands none
Examples To display the firmware version on a switch:
switch:admin> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v6.1.1
v6.1.1
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0