Concept Guide

54 Dell 8/4Gbps FC SAN Module Administrator’s Guide
53-1001345-01
portCfgShow
B
FC Fastwrite Displays ON when FC Fastwrite is enabled on the port or (..) or OFF when
disabled. Fastwrite is disabled by default. This value is set by the portCfg
fastwrite command.
Rate Limit Displays ON when ingress rate limit is set on the port or (..) or OFF when the
ingress rate limiting feature is disabled. This value is set by the portCfgQos
--setratelimit command. The default value is OFF.
Credit Recovery Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF
when the feature is disabled. This value is set by the portCfgCreditRecovery
command. The credit recovery feature is enabled by default, but only ports
configured as long distance ports can utilize this feature.
Port Auto Disable Displays On when the Auto Disable feature is enabled on a port. Displays (..)
or OFF when the feature is disabled. This feature causes ports to become
disabled when they encounter an event that would cause them to reinitialize.
This feature is enabled by the portCfgAutoDisable command. The feature is
disabled by default.
F_Port Buffers Displays the number of configured internal port (F_Port) buffers. Displays (..)
or OFF if no buffers are configured. The buffer value is set by the
portCfgfPortbuffers command.
Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to “Understanding Virtual Fabric restrictions” on page 32 snf “Understanding
Admin Domain restrictions” on page 33 for details.
Operands This command supports the following operands:
slot For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
port Specifies the number of the port to be displayed, relative to its slot for bladed
systems.
Use portCfgshow with one of the following options and optional arguments to display specific
FCIP-related parameters configured for a GbE port:
Examples To display the configuration settings for a single port on a switch with NPIV mode enabled:
switch:admin> portcfgshow 8
Area Number: 8
Speed Level: AUTO(HW)
Fill Word: 0(Idle-Idle)
Trunk Port ON
Locked N_Port OFF
Persistent Disable OFF
NPIV capability ON
QOS Port AE
Port Auto Disable: OFF
Rate Limit OFF
F_Port Buffers OFF
To display the configuration settings for all ports on a switch with NPIV Mode enabled:
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0