Owners Manual
Table 19. Optional Avocent iKVM Module
Optional Avocent iKVM Module
Externally accessible connectors
USB Two 4-pin, USB 2.0-compliant connectors for keyboard and mouse
support
ACI port RJ-45
Video 15-pin VGA
Table 20. Chassis Management Controller Module
Chassis Management Controller Module
Externally accessible connectors
Remote management Two dedicated 10/100/1000 Mb RJ-45 (for integrated Ethernet
remote access controller). Gb port connects to the external
management network. STK port allows CMCs in adjacent enclosures
to be daisy chained.
Serial 9-pin, DTE, 16550-compatible
Video 15-pin VGA
Battery CR 2032 3.0-V Lithium ion coin cell
Table 21. Enclosure Control Panel
Enclosure Control Panel
Externally accessible connectors
USB Two 4-pin, USB 2.0-compliant connectors for keyboard and mouse
support
Video 15-pin VGA
LCD panel features Four cursor control keys, one select key, LCD screen
Table 22. I/O Module Specifications
Cisco Nexus B22 Fabric Extender Module
Externally accessible connectors Sixteen 10 Gb (internal) Ethernet ports and Eight 10 Gigabit Ethernet
SFP+ ports that support 10Gbase-SR, 10Gbase-LR, and 10Gbase-ER
fabric connections.
Table 23. Environmental Specifications
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/
environmental_datasheets.
Standard Operating Temperature Continuous operation: 10 °C to 35 °C at 10% to 80% relative
humidity (RH), with 26 °C max dew point. De-rate maximum
allowable dry bulb temperature at 1 °C per 300 m above 900 m (1
°F per 550 ft).
Expanded Operating Temperature
NOTE: When operating in the expanded temperature
range, system performance may be impacted.
NOTE: When operating in the expanded temperature
range, ambient temperature warnings may be reported
on the LCD and in the System Event Log.
< 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
Technical Specifications 85