Deployment Guide

40 Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches,
and Dell Compellent Storage Array
Deployment/Configuration Guide
Figure 28 Storage Center System Manager GUI displays disk pool “Pool_1” with 1.64 TB free space
2. Since there are two fabrics, fabric A and fabric B, two fault domains are created. Domain 1 is already
created by default and all the FC ports are currently in domain 1. To create another domain, click
Storage Management on the top left of the webpage and then select System > Setup > Configure
Local Ports.
3. Next, click the Edit Fault Domains button at the bottom right of the dialog box.
4. On the next dialog box click the Create Fault Domain button on the lower right of the dialog box.
In the Name field type a name for the new domain. In this case, the name Domain 2 was used.
Make sure FC is selected in the Type field and click Continue. Figure 29 below shows a sceenshot
of the created second domain.
Figure 29 Creating an additional Fault Domain on Dell Compellent Storage Array