Deployment Guide
51 Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches,
and Dell Compellent Storage Array
Deployment/Configuration Guide
1. Fabric A Brocade FC Switch Zoning Configuration
On the fabric A FC switch you can see the WWPN of the server FCoE port is 20:01:90:b1:1c:cc:e2:6a
and the WWPNs of the storage ports are 50:00:d3:10:00:ed:b2:3b, 50:00:d3:10:00:ed:b2:3d,
50:00:d3:10:00:ed:b2:41, and 50:00:d3:10:00:ed:b2:43. This zoning configuration is allowing all four
storage ports to communicate only to each other and the server virtual FCoE port.
The zoning configuration can be confirmed with the zoneshow command.
Figure 39 Displaying zoning configuration on fabric A Brocade FC switch
> zonecreate financeServer1_p1_test, "20:01:90:b1:1c:cc:e2:6a; 50:00:d3:10:00:ed:b2:3b;
50:00:d3:10:00:ed:b2:3d; 50:00:d3:10:00:ed:b2:41; 50:00:d3:10:00:ed:b2:43"
> cfgcreate zoneCfg_test,"financeServer1_p1_test"
> cfgenable zoneCfg_test
> cfgsave