Deployment Guide
56 Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches,
and Dell Compellent Storage Array
Deployment/Configuration Guide
4.5 Verification on the Dell MXL w/ FC Flex IOM
1. To see information on NPIV devices logged into the fabric, use the show npiv devices command on
the Dell MXL switch as shown below. Note the FCoE MAC is 0e:fc:02:01:0f:01 (the FCoE Map +
FC_ID as expected).
Figure 44 ‘show npiv devices’ command output on fabric A Dell MXL switch
2. To see currently active FCoE VN_Port sessions, use the show fip-snooping sessions command.
Figure 45 ‘show fip-snooping enode’ command output on fabric A Dell MXL switch
3. To see all FCoE end-node (ENodes) , use the show fip-snooping enode command.
Figure 46 ‘show fip-snooping enode’ command output on fabric A Dell MXL switch