Administrator Guide
Table Of Contents
- Contents
- Figures
- Tables
- About This Document
- Understanding Fibre Channel Services
- Performing Basic Configuration Tasks
- Performing Advanced Configuration Tasks
- Routing Traffic
- Managing User Accounts
- Configuring Protocols
- Configuring Security Policies
- In this chapter
- ACL policies overview
- ACL policy management
- FCS policies
- DCC policies
- SCC policies
- Authentication policy for fabric elements
- IP Filter policy
- Creating an IP Filter policy
- Cloning an IP Filter policy
- Displaying an IP Filter policy
- Saving an IP Filter policy
- Activating an IP Filter policy
- Deleting an IP Filter policy
- IP Filter policy rules
- IP Filter policy enforcement
- Adding a rule to an IP Filter policy
- Deleting a rule to an IP Filter policy
- Aborting an IP Filter transaction
- IP Filter policy distribution
- Policy database distribution
- Management interface security
- Maintaining the Switch Configuration File
- Installing and Maintaining Firmware
- In this chapter
- Firmware download process overview
- Preparing for a firmware download
- Firmware download on switches
- Firmware download on an enterprise-class platform
- Firmware download from a USB device
- FIPS Support
- Test and restore firmware on switches
- Test and restore firmware on enterprise-class platforms
- Validating a firmware download
- Managing Virtual Fabrics
- In this chapter
- Virtual Fabrics overview
- Logical switch overview
- Logical fabric overview
- Management model for logical switches
- Account management and Virtual Fabrics
- Supported platforms for Virtual Fabrics
- Limitations and restrictions of Virtual Fabrics
- Enabling Virtual Fabrics mode
- Disabling Virtual Fabrics mode
- Configuring logical switches to use basic configuration values
- Creating a logical switch or base switch
- Executing a command in a different logical fabric context
- Deleting a logical switch
- Adding and removing ports on a logical switch
- Displaying logical switch configuration
- Changing the fabric ID of a logical switch
- Changing a logical switch to a base switch
- Setting up IP addresses for a Virtual Fabric
- Removing an IP address for a Virtual Fabric
- Configuring a logical switch to use XISLs
- Changing the context to a different logical fabric
- Creating a logical fabric using XISLs
- Administering Advanced Zoning
- In this chapter
- Special zones
- Zoning overview
- Broadcast zones
- Zone aliases
- Zone creation and maintenance
- Default zoning mode
- Zoning database size
- Zoning configurations
- Creating a zoning configuration
- Adding zones (members) to a zoning configuration
- Removing zones (members) from a zone configuration
- Enabling a zone configuration
- Disabling a zone configuration
- Deleting a zone configuration
- Clearing changes to a configuration
- Viewing all zone configuration information
- Viewing selected zone configuration information
- Viewing the configuration in the effective zone database
- Clearing all zone configurations
- Zone object maintenance
- Zoning configuration management
- Security and zoning
- Zone merging scenarios
- Traffic Isolation Zoning
- In this chapter
- Traffic Isolation Zoning overview
- Enhanced TI zones
- Traffic Isolation Zoning over FC routers
- General rules for TI zones
- Supported configurations for Traffic Isolation Zoning
- Limitations and restrictions of Traffic Isolation Zoning
- Admin Domain considerations for Traffic Isolation Zoning
- Virtual Fabric considerations for Traffic Isolation Zoning
- Traffic Isolation Zoning over FC routers with Virtual Fabrics
- Creating a TI zone
- Modifying TI zones
- Changing the state of a TI zone
- Deleting a TI zone
- Displaying TI zones
- Setting up TI over FCR (sample procedure)
- Administering NPIV
- Interoperability for Merged SANs
- In this chapter
- Interoperability overview
- Connectivity solutions
- Domain ID offset modes
- McDATA Fabric mode configuration restrictions
- McDATA Open Fabric mode configuration restrictions
- Interoperability support for logical switches
- Switch configurations for interoperability
- Zone management in interoperable fabrics
- Frame Redirection in interoperable fabrics
- Traffic Isolation zones in interoperable fabrics
- Brocade SANtegrity implementation in mixed fabric SANS
- E_Port authentication between Fabric OS and M-EOS switches
- FCR SANtegrity
- FICON implementation in a mixed fabric
- Fabric OS version change restrictions in an interoperable environment
- Coordinated Hot Code Load
- McDATA-aware features
- McDATA-unaware features
- Supported hardware in an interoperable environment
- Supported features in an interoperable environment
- Unsupported features in an interoperable environment
- Managing Administrative Domains
- In this chapter
- Administrative Domains overview
- Admin Domain management for physical fabric administrators
- Setting the default zoning mode for Admin Domains
- Creating an Admin Domain
- User assignments to Admin Domains
- Removing an Admin Domain from a user account
- Activating an Admin Domain
- Deactivating an Admin Domain
- Adding members to an existing Admin Domain
- Removing members from an Admin Domain
- Renaming an Admin Domain
- Deleting an Admin Domain
- Deleting all user-defined Admin Domains
- Deleting all user-defined Admin Domains non-disruptively
- Validating an Admin Domain member list
- SAN management with Admin Domains
- CLI commands in an AD context
- Executing a command in a different AD context
- Displaying an Admin Domain configuration
- Switching to a different Admin Domain context
- Admin Domain interactions with other Fabric OS features
- Admin Domains, zones, and zone databases
- Admin Domains and LSAN zones
- Configuration upload and download in an AD context
- Administering Licensing
- Monitoring Fabric Performance
- In this chapter
- Advanced Performance Monitoring overview
- End-to-end performance monitoring
- Frame monitoring
- ISL performance monitoring
- Top Talker monitors
- Adding a Top Talker monitor on an F_Port
- Adding Top Talker monitors on all switches in the fabric (fabric mode)
- Displaying the top n bandwidth-using flows on an F_Port
- Displaying top talking flows for a given domain ID (fabric mode)
- Deleting a Top Talker monitor on an F_Port
- Deleting the fabric mode Top Talker monitors
- Limitations of Top Talker monitors
- Trunk monitoring
- Displaying end-to-end and ISL monitor counters
- Clearing end-to-end and ISL monitor counters
- Saving and restoring monitor configurations
- Performance data collection
- Optimizing Fabric Behavior
- In this chapter
- Adaptive Networking overview
- Ingress Rate Limiting
- QoS: SID/DID traffic prioritization
- QoS zones
- QoS on E_Ports
- QoS over FC routers
- Virtual Fabric considerations for traffic prioritization
- High availability considerations for traffic prioritization
- Supported configurations for traffic prioritization
- Upgrade considerations for traffic prioritization
- Limitations and restrictions for traffic prioritization
- Setting traffic prioritization
- Setting traffic prioritization over FC routers
- Disabling QoS
- Bottleneck detection
- Supported configurations for bottleneck detection
- How bottlenecks are reported
- Limitations of bottleneck detection
- High availability considerations for bottleneck detection
- Upgrade and downgrade considerations for bottleneck detection
- Trunking considerations for bottleneck detection
- Virtual Fabrics considerations for bottleneck detection
- Access Gateway considerations for bottleneck detection
- Enabling bottleneck detection on a switch
- Excluding a port from bottleneck detection
- Displaying bottleneck detection configuration details
- Changing bottleneck alert parameters
- Displaying bottleneck statistics
- Disabling bottleneck detection on a switch
- Managing Trunking Connections
- Managing Long Distance Fabrics
- In this chapter
- Long distance fabrics overview
- Extended Fabrics device limitations
- Long distance link modes
- Configuring an extended ISL
- Buffer credit management
- Buffer-to-Buffer flow control
- Optimal buffer credit allocation
- Fibre Channel gigabit values reference definition
- Allocating buffer credits based on full-size frames
- Allocating buffer credits based on average-size frames
- Allocating buffer credits for F_Ports
- Displaying the remaining buffers in a port group
- Buffer credits for each switch model
- Maximum configurable distances for Extended Fabrics
- Buffer credit recovery
- Using the FC-FC Routing Service
- In this chapter
- FC-FC routing service overview
- Integrated Routing
- Fibre Channel routing concepts
- Setting up the FC-FC routing service
- Backbone fabric IDs
- FCIP tunnel configuration
- Inter-fabric link configuration
- FC Router port cost configuration
- EX_Port frame trunking configuration
- LSAN zone configuration
- Use of Admin Domains with LSAN zones and FCR
- Zone definition and naming
- LSAN zones and fabric-to-fabric communications
- Controlling device communication with the LSAN
- Setting the maximum LSAN count
- Configuring backbone fabrics for interconnectivity
- HA and downgrade considerations for LSAN zones
- LSAN zone policies using LSAN tagging
- LSAN zone binding
- Proxy PID configuration
- Fabric parameter considerations
- Inter-fabric broadcast frames
- Resource monitoring
- FC-FC Routing and Virtual Fabrics
- Upgrade and downgrade considerations for FC-FC routing
- Displaying the range of output ports connected to xlate domains
- M-EOS Migration Path to Fabric OS
- Inband Management
- Port Indexing
- FIPS Support
- Hexadecimal
- Index

Fabric OS Administrator’s Guide 119
53-1001763-02
Secure Shell protocol
6
Setting up SCP for configUploads and downloads
1. Log in to the switch as admin.
2. Type the configure command.
3. Type y or yes at the cfgload attributes prompt.
4. Type y or yes at the Enforce secure configUpload/Download prompt.
Example of setting up SCP for configUpload/download
switch:admin> configure
Not all options will be available on an enabled switch.
To disable the switch, use the "switchDisable" command.
Configure...
System services (yes, y, no, n): [no] n
ssl attributes (yes, y, no, n): [no] n
http attributes (yes, y, no, n): [no] n
snmp attributes (yes, y, no, n): [no] n
rpcd attributes (yes, y, no, n): [no] n
cfgload attributes (yes, y, no, n): [no] y
Enforce secure config Upload/Download (yes, y, no, n): [no] y
Enforce signature validation for firmware (yes, y, no, n): [no]
Secure Shell protocol
To ensure security, Fabric OS supports secure shell (SSH) encrypted sessions. SSH encrypts all
messages, including the client transmission of the password during login. The SSH package
contains a daemon (sshd), which runs on the switch. The daemon supports a wide variety of
encryption algorithms, such as Blowfish-Cipher block chaining (CBC) and Advanced Encryption
Standard (AES).
NOTE
To maintain a secure network, you should avoid using Telnet or any other unprotected application
when you are working on the switch.
The File Transfer Protocol (FTP) is also not secure. When you use FTP to copy files to or from the
switch, the contents are in clear text. This includes the remote FTP server's login and password.
Some example commands of this limitation are: supportSave -k, configUpload, configDownload, and
firmwareDownload.
Commands that require a secure login channel must originate from an SSH session. If you start an
SSH session, and then use the login command to start a nested SSH session, commands that
require a secure channel will be rejected.
Fabric OS v6.1.0 and later support OpenSSH protocol v2.0 (ssh2). For more information on SSH,
refer to the SSH IETF Web site:
http://www.ietf.org/ids.by.wg/secsh.html
For more information, refer to SSH, The Secure Shell: The Definitive Guide by Daniel J. Barrett,
Ph. D., Richard E. Silverman, and Robert G. Byrnes.